建筑施工·第45卷·第1期75承插型盘扣式脚手架搭设方案对材料用量的影响项广政上海宝冶建筑工程公司上海200941摘要:基于绿色施工理念,为了降低项目成本,优化建筑施工领域承插型盘扣式脚手架材料的使用量,结合项目实例,通过对梁、板支撑架的搭设形式、构配件材料、搭设参数等方面展开对比分析,确定了较优的搭设参数与材料选择及最经济的搭设方案,为类似工程模板支撑系统的选型提供了一定的借鉴。关键词:承插型盘扣式脚手架;搭设参数;材料用量;经济性中图分类号:TU69文献标志码:A文章编号:1004-1001(2023)01-0075-04DOI:10.14144/j.cnki.jzsg.2023.01.019InfluenceofErectionSchemeofSocketTypeDiscBuckledScaffoldonMaterialUtilizationAmountXIANGGuangzhengShanghaiBaoyeConstructionCo.,Ltd.,Shanghai200941,ChinaAbstract:Basedontheconceptofgreenconstruction,inordertoreducetheprojectcostandoptimizetheuseofsockettypediscbuckledscaffoldmaterialsintheconstructionfield,combinedwiththeprojectexample,throughthecomparativeanalysisoftheerectionform,componentmaterials,erectionparametersandotheraspectsofthebeamandslabsupportframe,theoptimalerectionparameters,materialselectionandthemosteconomicalerectionschemeweredetermined.Itprovidesareferencefortheselectionofformworksupportsysteminsimilarprojects.Keywords:sockettypediscbucklescaffold;erectionparameters;materialutilizationamount;economical地上12栋单体组成。地下室基础采用桩+筏板基础,结构形式为钢筋混凝土框架-剪力墙结构,筏板基础厚度500mm,混凝土强度C35P8;地下室夹层板厚130mm,混凝土强度C35;地下室顶板厚度300mm,混凝土强度C35P8;地下室框架柱截面尺寸500mm×500mm至1200mm×1200mm不等,混凝土强度C40~C55不等;地下室外墙厚度400、500mm,混凝土强度C35P8。地下室顶板标高多,高差大,层高5.0~12.8m不等,平均标高8.0m。在顶板变标高位置,存在较大超限梁,典型梁截面尺寸有600mm×4400mm、600mm×3300mm、600mm×2800mm、600mm×2400mm、600mm×1200mm、500mm×3000mm、500mm×1400mm等。3支撑架搭设参数比选3.1构配件材料确定3.1.1主要构配件材料基本参数盘扣式钢管支撑脚手架分为标准型(B型)和重型(Z型)共2种类型,其中标准型脚手架立杆外径为48.3mm,重型脚手架立杆外径为60.3mm。采用盘扣式钢管脚手架的...