分享
[www.staffempire.com]-BS EN 558-1-1996 Industrial valves — Face-to-face and centre-to-face dimensions of metal valves for use in flanged pipe systems.pdf
下载文档
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
www.staffempire.com www.staffempire.com-BS EN 558-1-1996 Industrial valves Face-to-face and centre
BRITISH STANDARDBS EN558-1:1996Industrial valves Face-to-face and centre-to-face dimensions of metal valves for use in flanged pipe systems Part 1:PN-designated valvesThe European Standard EN 558-1:1995 has the status of aBritish StandardICS 23.060.00Licensed Copy:Institute Of Technology Tallaght,Institute of Technology,Mon Jul 23 10:25:57 GMT+00:00 2007,Uncontrolled Copy,(c)BSIBS EN 558-1:1996This British Standard,having been prepared under thedirection of the EngineeringSector Board,was publishedunder the authority of the Standards Board and comes into effect on 15 May 1996 BSI 03-1999The following BSI references relate to the work on this standard:Committee reference PSE/7Draft for comment 91/81548 DCISBN 0 580 24710 4Committees responsible for this British StandardThe preparation of this British Standard was entrusted to Technical Committee PSE/7,Valves,upon which the following bodies were represented:Amalgamated Engineering UnionAssociation of Bronze and Brass FoundersBritish Foundry AssociationBritish Gas plcBritish Plumbing Fittings Manufacturers AssociationBritish Valve and Actuator Manufacturers AssociationBritish WaterChartered Institution of Building Services EngineersElectricity AssociationEnergy Industries CouncilEngineering Equipment and Materials Users AssociationGAMBICA(BEAMA)Ltd.Health and Safety ExecutiveInstitution of Mechanical EngineersLP Gas AssociationPipeline Industries GuildSociety of British Water IndustriesWater Services Association of England and WalesWest Midlands CBICoopted membersAmendments issued since publicationAmd.No.DateCommentsLicensed Copy:Institute Of Technology Tallaght,Institute of Technology,Mon Jul 23 10:25:57 GMT+00:00 2007,Uncontrolled Copy,(c)BSIBS EN 558-1:1996 BSI 03-1999iContentsPageCommittees responsibleInside front coverNational forewordiiForeword2Text of EN 558-13List of referencesInside back coverLicensed Copy:Institute Of Technology Tallaght,Institute of Technology,Mon Jul 23 10:25:57 GMT+00:00 2007,Uncontrolled Copy,(c)BSIBS EN 558-1:1996ii BSI 03-1999National forewordThis British Standard has been prepared by Technical Committee PSE/7 and is the English language version of EN 558-1:1995 Industrial valves Face-to-face and centre-to-face dimensions of metal valves for use in flanged pipe systems Part 1:PN-designated valves,published by the European Committee for Standardization(CEN).EN 558-1 was produced as the result of international discussions in which the United Kingdom took an active part.Together with BS EN 558-2:1996,it partially supersedes BS 2080:1989,which has been amended.A British Standard does not purport to include all the necessary provisions of a contract.Users of British Standards are responsible for their correct application.Compliance with a British Standard does not of itself confer immunity from legal obligations.Cross-referencePublication referred toCorresponding British StandardEN 26554:1991BS EN 26554:1991 Specification for face-to-face dimensions for flanged automatic steam trapsSummary of pagesThis document comprises a front cover,an inside front cover,pages i and ii,the EN title page,pages 2 to 22,an inside back cover and a back cover.This standard has been updated(see copyright date)and may have had amendments incorporated.This will be indicated in the amendment table on the inside front cover.Licensed Copy:Institute Of Technology Tallaght,Institute of Technology,Mon Jul 23 10:25:57 GMT+00:00 2007,Uncontrolled Copy,(c)BSIw w w.b z f x w.c o mEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 558-1October 1995ICS 23.060.00Descriptors:Industrial valves,valves-and fittings,cocks,flanged valves,metallurgical products,dimensions,generalitiesEnglish versionIndustrial valves Face-to-face and centre-to-face dimensions of metal valves for use in flanged pipe systems Part 1:PN-designated valvesRobinetterie industrielle Dimensions face-face et face-axe de la robinetterie mtallique utilise dans les systmes de canalisations brides Partie 1:Appariels de robinetterie dsigns PNIndustriearmaturen Baulngen von Armaturen aus Metall zum Einbau in Rohrleitungen mit Flanschen Teil 1:Nach PN bezeichnete ArmaturenThis European Standard was approved by CEN on 1995-10-16.CEN membersare bound to comply with the CEN/CENELEC Internal Regulations whichstipulate the conditions for giving this European Standard the status of anational standard without any alteration.Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to anyCEN member.This European Standard exists in three official versions(English,French,German).A version in any other language made by translation under theresponsibility of a CEN member into its own language and notified to theCentral Secretariat has the same status as the official versions.CEN members are the national standards bodies of Austria,Belgium,Denmark,Finland,France,Germany,Greece,Iceland,Ireland,Italy,Luxembourg,Netherlands,Norway,Portugal,Spain,Sweden,Switzerland andUnited Kingdom.CENEuropean Committee for StandardizationComit Europen de NormalisationEuropisches Komitee fr NormungCentral Secretariat:rue de Stassart 36,B-1050 Brussels 1995 All rights of reproduction and communication in any form and by any means reserved in allcountries to CEN and its membersRef.No.EN 558-1:1995 ELicensed Copy:Institute Of Technology Tallaght,Institute of Technology,Mon Jul 23 10:25:57 GMT+00:00 2007,Uncontrolled Copy,(c)BSIw w w.b z f x w.c o mEN 558-1:1995 BSI 03-19992ForewordThis European Standard was prepared by Technical Committee CEN/TC 69,Industrial valves,the secretariat of which is held by AFNOR.This European Standard shall be given the status of a national standard,either by publication of an identical text or by endorsement,at the latest by April 1996,and conflicting national standards shall be withdrawn at the latest by April 1996.This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association,and supports essential requirements of EC Directive(s).This standard was drawn up on the basis of the International Standard ISO/DIS 5752 and contains two Parts which can be used separately:EN 558-1,Industrial valves Face-to-face and centre-to-face dimensions of metal valves for use in flanged pipe systems Part 1:PN-designated valves.EN 558-2,Industrial valves Face-to-face and centre-to-face dimensions of metal valves for use in flanged pipe systems Part 2:Class-designated valves.The progress in work in the standardization of the different products can require a revision of the standard by adding or subtracting some basic series.In accordance with the CEN/CENELEC Internal Regulations,the following countries are bound to implement this European Standard:Austria,Belgium,Denmark,Finland,France,Germany,Greece,Iceland,Ireland,Italy,Luxembourg,Netherlands,Norway,Portugal,Spain,Sweden,Switzerland and United Kingdom.ContentsPageForeword20Introduction31Scope32Normative references33Definitions34Dimensions and tolerances3Annex A(informative)Origin of basic series20Figure 14Figure 24Table 1 Dimensions of basic series5Table 2 Tolerances7Table 3 Gate valves8Table 4 Butterfly valves Flanged type9Table 5 Butterfly valves Wafer type10Table 6 Plug valves and ball valves11Table 7 Diaphragm valves11Table 8 Globe valves Straight and oblique pattern12Table 9 Globe valves and lift checkvalves Angle pattern13Table 10 Check valves Flanged type14Table 11 Check valves Wafer type15Table 12 Globe control valves Straight pattern16Table 13 Globe control valves Angle pattern16Table 14 Butterfly control valves Flanged type17Table 15 Butterfly control valves Wafer type18Table 16 Eccentric rotary plug controlvalves and segmented ball controlvalves Wafer type and flanged type18Table 17 Ball control valves19Table A.1 Origin of basic series20Licensed Copy:Institute Of Technology Tallaght,Institute of Technology,Mon Jul 23 10:25:57 GMT+00:00 2007,Uncontrolled Copy,(c)BSIw w w.b z f x w.c o mEN 558-1:1995 BSI 03-199930 IntroductionAll tables of face-to-face and centre-to-face dimensions are drafted separately for PN-designated valves in EN 558-1 and for Class designated valves in EN 558-2.The basic series in this standard are taken from the origin series shown in Annex A(informative).Changes made to the origin series will not be automatically incorporated into this standard.The numbers of the basic series are maintained as in ISO/DIS 5752:1993.1 ScopeThis Part of this standard specifies face-to-face(FTF)and centre-to-face(CTF)dimensions for PN designated metal valves used in flanged pipe systems.This Part of this standard covers valves having the following PN and DN values:PN 2,5;PN 6;PN 10;PN 16;PN 25;PN 40;PN 63;PN 100.DN 10;DN 15;DN 20;DN 25;DN 32;DN 40;DN 50;DN 65;DN 80;DN 100;DN 125;DN 150;DN 200;DN 250;DN 300;DN 350;DN 400;DN 450;DN 500;DN 600;DN 700;DN 800;DN 900;DN 1 000;DN 1 200;DN 1 400;DN 1 600;DN 1 800;DN 2 000.Face-to-face dimensions of automatic steam traps are specified in EN 26554.2 Normative referencesThis standard incorporates,by dated or undated reference,provisions from other publications.These normative references are cited at the appropriate places in the text and the publications are listed hereafter.For dated references,subsequent amendments to or revisions of the cited publication apply to this European Standard,only when incorporated in it by amendment or revision.For undated references,the latest edition of the publication referred to applies.EN 736-1,Valves Terminology Part 1:Definitions of types of valves.EN 26554,Flanged automatic steam traps Face-to-face dimensions.3 DefinitionsFor the purposes of this standard,prEN 736-1 and the following definitions apply:3.1 face-to-face dimension(FTF)(for straight pattern valves)the distance,expressed in millimetres,between the two planes perpendicular to the valve axis located at the extremities of the body end ports or as may be specified in the relevant valve product standard(see Figure 1 and Figure 2)3.2 centre-to-face dimension(CTF)(for angle pattern valves)the distance,expressed in millimetres,between the plane located at the extremity of either body end port and perpendicular to its axis and the axis of the other body end port(see Figure 1 and Figure 2)4 Dimensions and tolerances4.1 Basic seriesThe basic series of FTF and CTF dimensions shall be as given in Table 1.For each type of valve,the basic series to be taken into consideration are given in Table 3 to Table 17.4.2 Dimensions for unlined valvesFor unlined valves the FTF and CTF dimensions shall be in accordance with Figure 1 and Figure 2.4.3 Dimensions for lined valves4.3.1 For valves having a resilient lining which forms the gasket joint with the mating flanges,the FTF and CTF dimensions shall be the distance between the extremities of the valve in the installed condition.The overall valve dimensions before assembly shall be provided by the manufacturer.4.3.2 For valves having resilient or hard linings as a regular production feature the thickness of the lining on the mating surface shall be included in the FTF and CTF dimensions given in Table 1,unless the design of the valve precludes such an inclusion.Where the design does not permit the lining to be included in the FTF and CTF dimensions given in Table 1,then the thickness of the lining may be added to the basic dimension.4.3.3 For valves having resilient or hard linings which are not normally a regular production feature,the thickness of the lining on the flange faces may be added to the FTF and CTF dimensions given in Table 1.Licensed Copy:Institute Of Technology Tallaght,Institute of Technology,Mon Jul 23 10:25:57 GMT+00:00 2007,Uncontrolled Copy,(c)BSIw w w.b z f x w.c o mEN 558-1:19954 BSI 03-19994.4 TolerancesTolerances on FTF and CTF dimensions are given in Table 2.Figure 1 Figure 2 Licensed Copy:Institute Of Technology Tallaght,Institute of Technology,Mon Jul 23 10:25:57 GMT+00:00 2007,Uncontrolled Copy,(c)BSIw w w.b z f x w.c o mEN 558-1:1995 BSI 03-19995Table 1 Dimensions of basic seriesDimensions in millimetresDNBasic series1234578a9a1011a12131415161819202122a23a2510152013013015021021023010210811714015216519010810811790909510510511510811757 641301301301151151208080901401521521786565707070752532401601802002302602601271401651651781902162292411271461591001051151151301301271401657076831401651651061251301401201402403310011012016517819033216229241809095859510050658023029031030034038017819020321624128329233035619021625412514515515017019020321624110210812120322224110811211415017018025027028043466413516518521624128343464626729231810511512511512513549100125150350400480430500550229254267305381403432508559305356406175200225215250275292330356146178203305356394127140140190200210300325350647076229305381403525656356400444135146566470200250300600730850650775900292330356419457502660787838521635749275325375325495622698248311349457533610152165178230250270400450500891141144194575026068785336227117176833504004509801 1001 2001 0251 1501 2753814064327628389148899911 09242547550078791497839445748368676286419021622229031033055060065012714015257261066078102114838864978921021145006007001 2501 4501 6501 4001 6004575086109911 1431 1941 3979781 2951 4489141 0672292672923503904307008009001521782297117871271541651 0161 3461 4991271548009001 0001 8502 0502 2506607118131 6761 9563183304104705105501 0001 1001 2002412413001902032161 7782 0831 2001 4001 6004705306006307107903503904402542793181 8002 000670760870950490540356406Licensed Copy:Institute Of Technology Tallaght,Institute of Technology,Mon Jul 23 10:25:57 GMT+00:002007,Uncontrolled Copy,(c)BSIw w w.b z f x w.c o mEN 558-1:19956 BSI 03-1999 Table 1 Dimensions of basic seriesDimensions in millimetresDNBasic series26272829303637383940a41a42a43444546474849505153101520115115120130130150108108117,51501607690100140152165250751619253240240125130140160180200127127136160180190102114184222197235210251921119811710512511513015036382102302402552652808090100180222831,5385065802502903101501701802302903101421541602002152301241652542982673172863371271491331591431681704042442502702803003403601101301502002402604046505454575460674042441001251503504004501903253503504004501721862002502753001942293524513684733945081762251842361972544648503003503754004505001602002103003504006090106647076678395464850200250300550650750400450500550650750228255285350400425243297338543673737568708775610752819272337368284354387305376410606575425450500600700800500600700140951081431271401816065753504004508509501 0505507628509503153403604755255754008891 0169271 0579721 10844550846452948655480951075506008009001 00018419120322223226480951075006007001 1501 3501 5509141 1503804254706257258251201441601 1001 3001 5002132223212923183811201441608009001 0001 7501 9502 1505105556009251 0251 1251801952101 7001 9002 1003563684194891801952101 2001 4001 6001 8002 000NOTE 1Table 1 gives complete series.In Table 3 to Table 17 the columns of series may be incomplete.NOTE 2For ce

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开