分享
IEC_870-5-101_2.pdf
下载文档

ID:236717

大小:1.24MB

页数:168页

格式:PDF

时间:2023-03-14

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
IEC_870 101 _2
Norwegian IEC 870-5-101User ConventionsApproved versionRevision no.2.0Revision no.:Date:Chapter:Comments:1.097-09-24AllInitial version1.197-10-24AllChanges in fonts and figure ref.,and insert ofchapter 7.4-7.61.298-02-197Foreword added.Redundant communicationclarified.Sequences added for redundantcommunication.1.398-03-195.2.1.11-5.2.1.16Terminology changed for full time ASDUs tocorrespond to IEC standard5.2.4.5ASDU for Line Activation Cmd.added5.2.5.1ASDU figure corrected7.2.2Chapter for redundant lines balanced moderewritten1.498-12-01Fig.6.3,6.10,6.13,6.15,6.20,6.21Text in figures FIXED FRAME FC=0,ACD=1changed to“ACK”Fig.6.7 and6.8Text in figures FIXED FRAME FC=9,ACD=0changed to“NACK”5.1.1Multiple point to point made eligible ininteroperability list.5.1.4 made eligible in interoperability list.5.1.5Interoperability list(command transmission)mademore detailed.“No additional definition”madeeligible.5.2.2.4Activation termination added as possible cause oftransmission.5.2.4.4Typo corrected5.2.4.5Removed6.1.7More detailed description added7.2.2Chapter for redundant lines balanced moderewritten7.5Clarified2.000-03-24ForewordText regarding the maintenance of the documentadded.1Texts added regarding existence ofsupplementary definitions to IEC 870-5-101 andthe priority of documents if conflict betweendocuments occurs2.3Definition of controlling and controlled stationadded4.2Added:Day of week is not used and set to 0.4.2.9Text removed:Two octet Common addresses canbe used within NUC5.1Interoperability-Text modified due to newnotation.Additional functions/ASDUs can be usedon project bases.5.1.1-5.1.5Notation for selected functions/ASDUs in theinteroperability list modified.5.1.4ASDUs with time tag:2,4,10 and 14 notselectable.(ASDUs with time tag CP56Time2ashall be used instead)5.1.5C_SE ACTTERM used changed to NOT set inInteroperability list5.2.1.25.2.1.45.2.1.8ASDUs with time tag:2,4,10 and 14 notselectable.(ASDUs with time tag CP56Time2ashall be used instead)5.2.1.125.2.1.135.2.1.145.2.1.155.2.1.16Type identification presented in Data unitidentifiers in Fig.16,17,18,19 and 20 correctedText(Not used=0)added for Days of week1.75.2.1.9Sequence of information elements(SQ=1)nowsupported for ASDU 13(included insupplementary definitions to IEC 870-5-101)5.2.4.2Information object address should be=06.1.7Detailed description regarding select and executecommand added.6.1.9Text added:IOAs of parameters should be equalto the IOAs to the related measured values6.2.1.3Detailed description regarding the use of theDCF bit added.6.2.2.4Paragraph outlined in bold7.1Measurands changed to Measured values7.1.2Type of indication and recommended IOA for thebuffer overflow event added7.1.4Text added:SQ=1 should be used for Measuredvalues as response to general interrogation7.3.4Typo corrected.7.8New chapter describing scaling of normalisedmeasured values,measured value parametersand set point commands added.IEC 870-5-101Norwegian User Conventions2000-03-24Revision no.2.0 side 3FOREWORD.71INTRODUCTION.82PROTOCOL STRUCTURE.92.1Communication Protocol.92.2Anatomy of a communication Protocol.92.3Definitions.102.4Protocol structure.113TRANSMISSION SPECIFICATIONS.133.1Network configurations.133.2Protocol character format.143.3Transmission rules.154TRANSMISSION FRAME FORMATS.164.1Standard frame formats.164.2General structure of application data.184.2.1Start character/length.204.2.2Control field.204.2.3Control field unbalanced mode:.214.2.4Control field balanced mode:.244.2.5Link address:.274.2.6Type identification:.274.2.7Variable structure qualifier:.284.2.8Cause of transmission.294.2.9Common address of ASDUs.314.2.10 Information object address.314.2.11 Information of elements.324.3Presentation of frame with fixed length,unbalanced mode.334.4Presentation of frame with fixed length,balanced mode.355APPLICATION LAYER TELEGRAM FORMATS.415.1Interoperability.415.1.1Network configuration.415.1.2Physical layer.415.1.3Link layer.425.1.4Application layer.425.1.5Basic application functions.455.2Definition and presentation of the specific ASDUs.475.2.1ASDUs for process information in monitor direction.475.2.1.1Single-point information without time tag.475.2.1.2Single-point information with time tag(not used).515.2.1.3Double-point information without time tag.535.2.1.4Double-point information with time tag(not used).575.2.1.5Step position information.595.2.1.6Bitstring of 32 bit.615.2.1.7Measured value,normalised value.635.2.1.8Measured value,normalised value with time tag(not used).67IEC 870-5-101Norwegian User Conventions2000-03-24Revision no.2.0 side 45.2.1.9Measured value,short floating point number.695.2.1.10Integrated totals with time tag(not used).735.2.1.11Single-point information with time tag CP56Time2a.755.2.1.12Double-point information with time tag CP56Time2a.775.2.1.13Step position information with time tag CP56Time2a.805.2.1.14Measured value,normalised value with time tag CP56Time2a.825.2.1.15Measured value,short floating point number with

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开