温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
IEC_62439
2011
_cor1
2015
IEC 62439-7:2011/COR1:2015 1 IEC 2015 INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION LECTROTECHNIQUE INTERNATIONALE _ IEC 62439-7 Edition 1.0 2011-12 INDUSTRIAL COMMUNICATION NETWORKS HIGH AVAILABILITY AUTOMATION NETWORKS Part 7:Ring-based Redundancy Protocol(RRP)IEC 62439-7 dition 1.0 2011-12 RESEAUX DE COMMUNICATION INDUSTRIELS RESEAUX DE HAUTE DISPONIBILITE POUR LAUTOMATION Partie 7:Protocole de redondance pour rseau en anneau(RRP)C O R R I G E N D U M 1 Corrections to the French version appear after the English text.Les corrections la version franaise sont donnes aprs le texte anglais.10 RRP Management Information Base(MIB)Replace the existing text in Clause 10 with the following text(note that only sections highlighted in yellow have actually been changed):-*IEC-62439-7-MIB DEFINITIONS:=BEGIN -*-Imports-*IMPORTS OBJECT-IDENTITY,OBJECT-TYPE,TimeTicks,Counter32,Unsigned32,Counter64,VISIBLE-STRING,INTEGER FROM SNMPv2-SMI Boolean FROM HOST-RESOURCES-MIB MacAddress FROM BRIDGE-MIB iso FROM RFC1155-SMI;-*-Declaration of TIMEOFDAY-*TIMEOFDAY :=TEXTUAL-CONVENTION STATUS current DESCRIPTION The IEC 61158-5-21 defines the structure of the TIMEOFDAY as a data type numeric identifier 12.SYNTAX VISIBLE STRING(SIZE(6)-*IEC 6439-7:2011-12/COR1:2015-05(en-fr)2 IEC 62439-7:2011/COR1:2015 IEC 2015-Root OID-*iec62439 MODULE-IDENTITY LAST-UPDATED 201306110000Z -June 11,2013 ORGANIZATION IEC/SC 65C CONTACT-INFO International Electrotechnical Commission IEC Central Office 3,rue de Varembe P.O.Box 131 CH-1211 GENEVA 20 Switzerland Phone:+41 22 919 02 11 Fax:+41 22 919 03 00 email:infoiec.ch DESCRIPTION This MIB module defines the Network Management interfaces for the Redundancy Protocols defined by the IEC standard 62439.REVISION 201306110000Z -June 11,2013 DESCRIPTION Consistency adjustment with other parts of IEC 62439 REVISION 200811100000Z -November 10,2008 DESCRIPTION Seperation of IEC 62439 into a suite of documents.This MIB applies to IEC 62439-7,added RRP functionality.REVISION 200708240000Z -August 24,2007 DESCRIPTION Initial version of the Network Management interface for the Ring-based Redundancy Protocol :=IEC 62439 -*-Redundancy Protocols-*mrp OBJECT IDENTIFIER:=iec62439 1 prp OBJECT IDENTIFIER:=iec62439 2 crp OBJECT IDENTIFIER:=iec62439 3 brp OBJECT IDENTIFIER:=iec62439 4 drp OBJECT IDENTIFIER:=iec62439 5 rrp OBJECT IDENTIFIER:=iec62439 6 -*-Objects of the RRP Network Management-*ServiceID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS mandatory DESCRIPTION specifies information sufficient for local identification of the RRP device that will convey the service :=rrp 1 InvokeID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS mandatory DESCRIPTION specifies the invocation of the service :=rrp 2 DeviceAddress OBJECT-TYPE SYNTAX INTEGER IEC 62439-7:2011/COR1:2015 3 IEC 2015 MAX-ACCESS read-write STATUS mandatory DESCRIPTION specifies the value for the RRP device address :=rrp 3 DeviceFlags OBJECT-TYPE SYNTAX BITS DeviceAddressCollision(0),DeviceStateChanged(1)MAX-ACCESS read-only STATUS mandatory DESCRIPTION specifies the flags for events that occurred in a local device :=rrp 4 DeviceState OBJECT-TYPE SYNTAX INTEGER Invalid(0),SA(1),LNM(2),GD(3),RNMP(4),RNMS(5)MAX-ACCESS read-only STATUS mandatory DESCRIPTION specifies the device state of the RRP device :=rrp 5 DeviceUID OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS mandatory DESCRIPTION specifies the unique 8-octet identification that identifies a RRP device in a network :=rrp 6 DeviceUIDRport1 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS mandatory DESCRIPTION specifies the UID of the device that is linked through the R-port1 :=rrp 7 DeviceUIDRport2 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS mandatory DESCRIPTION specifies the UID of the device that is linked through the R-port2 :=rrp 8 MACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS mandatory DESCRIPTION specifies the MAC address of the RRP device :=rrp 9 Rport1Information OBJECT-TYPE SYNTAX BITS PortLinkDown(0),4 IEC 62439-7:2011/COR1:2015 IEC 2015 PortCFMFamily(1),PortWaitADV(2),PortWaitML(3)PortCFM(4)MAX-ACCESS read-only STATUS mandatory DESCRIPTION specifies the port information for R-port1 :=rrp 10 Rport2Information OBJECT-TYPE SYNTAX BITS PortLinkDown(0),PortCFMFamily(1),PortWaitADV(2),PortWaitML(3)PortCFM(4)MAX-ACCESS read-only STATUS mandatory DESCRIPTION specifies the port information for R-port2 :=rrp 11 Version OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS mandatory DESCRIPTION specifies the protocol version of the RRP device :=rrp 12 DeviceType OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS mandatory DESCRIPTION specifies the local device type that represents the general function of the device :=rrp 13 DeviceDescription OBJECT-TYPE SYNTAX VISIBLE STRING(SIZE(1.16)MAX-ACCESS read-write STATUS mandatory DESCRIPTION specifies a description of the local device :=rrp 14 FamilyResWaitingTime OBJECT-TYP