温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
IEC_Electronic_Timers_Protective_Relays
GE Industrial SystemsCatalogApplication,Selection&Pricing IEC Electronic Timers&Protective Relays1IEC Electronic Timers&Protective RelaysSelection/Pricing Page45666666778999Protective relaysMultivoltage electronic timersOrdering data,see p.2-9Technical data,see p.10-36Dimensional drawings,see p.37-38222223223333111del+11111111221inst2222220.6s0.06s0.6s 0.6s 10.6s 0.50.6s0.6s 0.6s 0.60.6s606060606060500 606060min.50min.hmin.min.smin.smin.min.min.60hmin.MultivoltageMTCVMTCVLMTCIVMTCCVMETVMTDVMRDVMICVMIFVMIVVMIVVLMMFVSelection/Pricing PageDelayed ONON delay with auxiliary contactON delay+instantaneous contactOFF delayOFF delay with auxiliary contactON+OFF delay with auxiliary contactImpulse ONImpulse ON with auxiliary contactOFF pulse with auxiliary contactSymmetric intermittenceAsymmetric intermittenceStar-delta starterMultifunctionFeaturesMultirange of timeTime setting range fromtoRelay output(Nr.of changeover contacts)FunctionsTypesVoltageDINILRDH/T/ARDFF1RPDFRDMT1RSFFRTMMRMMRDTRDIRDITRS01NRSRRCFSingle voltageLiquid level detectionDifferential ground faultIntegral protection for three-phase linesUnbalance and phase failure protectionUnbalance,phase failure and min.voltage protectionPhase sequence and phase failure protectionMax.and min.voltage protection(three-phase)Max.and min.voltage protection(single phase)Voltage detectionCurrent detectionCurrent detection with delay(0.5-15s)ThermistorThermistor(adjustable)Frequency controlFunctionsTypesVoltage121213141516151317181920Technical Data Page2125262728293030313233343535Technical Data PagePRODUCT LINE OVERVIEWS2IEC Electronic Timers&Protective RelaysSupply voltageTime rangeAvailable contactsCat.no.(1)List Price,GO-10RTDelayed ON timersDirect0.6-6 sec.1 selectable NO-NCMTCV$61.0024-240V AC/DC6-60 sec.2 selectable NO-NCMTCV2 75.00With transformer0.6-6 min.1 selectable NO-NCMTCVTG 79.006-60 min.Long time delayed ON timersDirect0.06-0.6 sec.1 selectable NO-NCMTCVL 64.0024-240V AC/DC0.6-6 sec.2 selectable NO-NCMTCVL2 78.00With transformer0.6-6 h.1 selectable NO-NCMTCVLTG 82.006-60 h.Delayed ON timer with instantaneous contactDirect0.6-6 sec.1 timed contactMTCIV64.0024-240V AC/DC6-60 sec.+1 instant contact0.6-6 min.6-60 min.Delayed ON through contactDirect0.6-6 sec.1 selectable NO-NCMTCCV65.0024-240V AC/DC6-60 sec.With transformer0.6-6 min.1 selectable NO-NCMTCCVTG83.006-60 min.Impulse ON timerDirect0.6-6 sec.1 selectable NO-NCMICV65.0024-240V AC/DC6-60 sec.2 selectable NO-NCMICV278.00With transformer0.6-6 min.1 selectable NO-NCMICVTG83.006-60 min.Star-delta starter timersDirect 24-240V AC/DC1-10 sec.2 timedMETV89.00With transformer1-60 sec.2 timedMETVTG107.00Delayed OFF timersDirect0.5-6 sec.1 selectable NO-NCMRDV-681.0024-240V AC/DC5-60 sec.1 selectable NO-NCMRDV-6081.0050-600 sec.1 selectable NO-NCMRDV-60081.000.5-6 sec.2 selectable NO-NCMRDV2-689.005-60 sec.2 selectable NO-NCMRDV2-6089.0050-600 sec.2 selectable NO-NCMRDV2-60089.00With transformer0.5-6 sec.1 selectable NO-NCMRDVT-6G93.00(up to 440V)5-60 sec.1 selectable NO-NCMRDVT-60G93.0050-600 sec.1 selectable NO-NCMRDVT-600G93.00Multivoltage electronic timers(1)To complete the catalog number,replace the symbol G with the code corresponding to the voltage.See p.10-11MTCVMTCIVMRDVTechnical data.Typesee page MTCV12 MTCVL12 MTCIV13 MTCCV14 MICV13 METV15 MRDV15Dimensions,see p.37Contact diagrams.1 selectable NO-NC 2 selectable NO-NC2 timed3IEC Electronic Timers&Protective RelaysSupply voltageTime rangeAvailable contactsCat.no.(1)List Price,GO-10RTMultivoltage electronic timers(1)To complete the catalog number,replace the symbol G by the code corresponding to the voltage.See p.10-11Delayed OFF through contact timerDirect0.6-6 sec.1 selectable NO-NCMTDV$56.0024-240V AC/DC6-60 sec.With transformer0.6-6 min.1 selectable NO-NCMTDVTG74.006-60 min.Symmetric intermittenceDirect0.6-6 sec.1 selectable NO-NCMIFV108.0024-240V AC/DC6-60 sec.2 selectable NO-NCMIFV2122.00With transformer0.6-6 min.1 selectable NO-NCMIFVTG126.006-60 min.Asymmetric intermittence,started by connection or pause(choice)Direct0.6-6 sec.1 selectable NO-NCMIVV108.0024-240V AC/DC6-60 sec.2 selectable NO-NCMIVV2122.00With transformer0.6-6 min.1 selectable NO-NCMIVVTG126.006-60 min.Long time asymmetric intermittence,started by connection or pause(choice)Direct0.6-6 min.1 selectable NO-NCMIVVL110.0024-240V AC/DC6-60 min.2 selectable NO-NCMIVVL2125.00With transformer0.6-6 h.1 selectable NO-NCMIVVLTG130.006-60 h.Multifunction timerDelayed ON timerImpulse ON timerDelayed ON through contact timerImpulse ON through contact timerDelayed OFF through contact timerImpulse OFF through contact timerDelayed ON and OFF through contact timerImpulse ON and OFF through contact timerDirect0.6-6 sec.1 selectable NO-NCMMFV120.0024-240V AC/DC6-60 sec.0.6-6 min.6-60 min.Multifunction timer-large 45 mmDelayed ON timerImpulse ON timerDelayed ON through contact timerImpulse ON through contact timerDelayed OFF through contact timerImpulse OFF through contact timerDelayed ON and OFF t