分享
IEC_61375-2-3-2015_cor2-2016.pdf
下载文档

ID:234217

大小:316.67KB

页数:10页

格式:PDF

时间:2023-03-14

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
IEC_61375 2015 _cor2 2016
IEC 61375-2-3:2015/COR2:2016 1 IEC 2016 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ IEC 61375-2-3 Edition 1.0 2015-07 ELECTRONIC RAILWAY EQUIPMENT TRAIN COMMUNICATION NETWORK(TCN)Part 2-3:TCN communication profile C O R R I G E N D U M 2 5.3.2.3 Replace existing Figure 15 by the following new Figure.all statesWaitForEtbInaugTrnDirSetupInitial/resetTrnDirtxTimerExpired/sendCiCtrl/sendCstInfoCond/startTxTimerWaitForCstInfociCtrlAll=TRUE ORetbWaitTimerExpired/sendCstInfoCond/startTxTimer/startEtbWaitTimercstInfoReceived/updateTrnDir/sendCstInfoCond/startTxTimer/startEtbWaitTimerinaugIndication/compReset/stopOpTrnDirProcess/resetTrnDir/sendCiCtrl/startTxTimer/startEtbWaitTimertxTimerExpired/sendCiCtrl/startTxTimeretbWaitTimerExpired /checkExpiredCiCtrl/updateTrnDir/startEtbWaitTimertxTimerExpired/sendCstInfoCond/sendCiCtrlCond2/startTxTimerciCtrlReceived/processCiCtrlciAll=TRUE/sendCiCtrlCond1ciAll=FALSEcstInfoReceived/updateTrnDirtrnTopoCntValid=TRUE/startOpTrnDirProcess/startTxTimer IEC IEC 61375-2-3:2015-07/COR2:2016-10(en)2 IEC 61375-2-3:2015/COR2:2016 IEC 2016 Table 5 Add the following entry at the end of the table.Action Description compReset Reset the composition by triggering the event compReset in the leading function state machine(see 6.5.3.2)and the confirmation/correction state machine(see 6.6.4).5.3.3.2.16,item d)Replace existing item d)by the following new text.d)Setting the topography counter to a value of 0 declares the topography counter to be invalid.5.4.4.6.1 Replace existing Figure 20 by the following new figure.121212 121212train consist number(trnCstno):consist vehicle orientation(vehOrient):01inversetrain(reference)directionoperat.train veh.number(opTrnVehNo):02050301train consist orientation(cstOrient):inverseoperational train(reference)directionconsist vehicle number(cstVehNo):030202010103consist(reference)direction consist(reference)direction 02directlowest consist UUID operat.train consist number(opCstNo):02operat.train consist orientation(opCstOrient):direct 01inverseconsist UUID(cstUUID):vehicle identifier(vehId/idVeh):1)UIC508089435012UIC508089435020UIC508089435038UIC508089436036UIC508089436028UIC5080894360100406inversedirectdirectdirectinverse12123Leading cab3train vehicle number(trnVehNo):0105020304063026cede-c9e8-11e3-9d46-1a514932ac016a4a96fe-c9e8-11e3-9d46-1a514932ac01consist identifier(cstId/idCst):1)UIC508089435038UIC5080894360361)Identifiers as defined by UIC are used in these examples,e.g.UIC508089435038 corresponds to UIC identifier 50 80 89 43 503-8 IEC 5.4.5.2,second paragraph following note 1 Replace the existing text by the following new text.The decomposition for ETB-related groups is defined as:11101111.11000001.bbgggggg.gggggggg 5.4.5.2,second paragraph following Table 20 Replace the existing text by the following new text.The decomposition for ETB-related groups is defined as:11101111.11000010.bbgggggg.gggggggg 5.5.3 Examples,last bullet item preceding Figure 21 Replace the existing text by the following new text.-group doorCTRLfctDoor.anyVeh.cst03.anyClTrn.lTrn in consist E IEC 61375-2-3:2015/COR2:2016 3 IEC 2016 5.5.3,Example 3,first two sentences Replace the existing text by the following new text.The following example shows how a TCN-URI can be resolved to a train wide multicast group address.Here it is assumed that the IP MC group fctDoor has been defined as a train wide group with a group Id=50.5.5.3,Example 4,text preceding Table 26 Replace the existing text by the following new text.The following example shows how a TCN-URI can be resolved to a consist-limited multicast group address.Here it is assumed that the two door controllers in consist E form a multicast group with group Id=50.For resolving the TCN-URI doorCTRLfctDoor.anyVeh.cst03.anyClTrn.lTrn”the ETB0 DNS server has to execute the steps as listed in Table 26:Table 26,step 1,last column Replace the existing text by the following new text.=“fctDoor.anyVeh.cst03 Table 26,step 2,second column Replace the existing text by the following new text.Lookup cstUUID of label cstNo=3 in the train directory of the local TTDB 6.4.5.2,Table 28,2nd column,2nd box Replace the existing text by the following new text.Stop processing of the operational train directory,triggered by the train directory computation state machine,see.5.3.2.If the transmission of ETBCTRL telegram continues,telegram parameter trnTopoCnt shall be set to 0 until processing of the operational train directory is restarted(trigger startOpTrnDirProcess)6.5.3.2,Figure 30 Replace existing Figure 30 by the following new figure.4 IEC 61375-2-3:2015/COR2:2016 IEC 2016 all statesWaitForLeadReqWaitForAcceptWaitForLeadWaitForLedIsLedinitial/isLead=FALSE/wasLead=FALSE/accLead=FALSE/reqLead=FALSE/leadConfl=FALSEclientReqLead=FALSE/reqLead=FALSE/isLead=FALSEclientReqLead=TRUE/reqLead=TRUE/setLeadDirremIsLead=FALSE/computeOpTrnDirremReqLead=TRUE AND reqLead=FALSE/accLead=TRUEreqLead=FALSE/leadConfl=FALSEremReqLead=FALSE/accLead=FALSEwasLead=FALSE AND remReqL

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开