分享
IEC_61970-301_Ed.4.pdf
下载文档

ID:234110

大小:1.64MB

页数:311页

格式:PDF

时间:2023-03-14

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
IEC_61970 301 _Ed
FORM CDV(IEC)2009-01-09 Registered trademark of the International Electrotechnical Commission 57/1196/CDV COMMITTEE DRAFT FOR VOTE(CDV)PROJET DE COMIT POUR VOTE(CDV)Project number Numro de projet IEC 61970-301 Ed.4 IEC/TC or SC:CEI/CE ou SC:57 Secretariat/Secrtariat Germany Submitted for parallel voting in CENELEC Soumis au vote parallle au CENELEC Date of circulation Date de diffusion 2011-12-02 Closing date for voting(Voting mandatory for P-members)Date de clture du vote(Vote obligatoire pour les membres(P)2012-05-04 Also of interest to the following committees Intresse galement les comits suivants-Supersedes document Remplace le document 57/1187/RR Proposed horizontal standard Norme horizontale suggre Other TC/SCs are requested to indicate their interest,if any,in this CDV to the TC/SC secretary Les autres CE/SC sont requis dindiquer leur intrt,si ncessaire,dans ce CDV lintention du secrtaire du CE/SC Functions concerned Fonctions concernes Safety Scurit EMC CEM Environment Environnement Quality assurance Assurance qualit CE DOCUMENT EST TOUJOURS LTUDE ET SUSCEPTIBLE DE MODIFICATION.IL NE PEUT SERVIR DE RFRENCE.LES RCIPIENDAIRES DU PRSENT DOCUMENT SONT INVITS PRSENTER,AVEC LEURS OBSERVATIONS,LA NOTIFICATION DES DROITS DE PROPRIT DONT ILS AURAIENT VENTUELLEMENT CONNAISSANCE ET FOURNIR UNE DOCUMENTATION EXPLICATIVE.THIS DOCUMENT IS STILL UNDER STUDY AND SUBJECT TO CHANGE.IT SHOULD NOT BE USED FOR REFERENCE PURPOSES.RECIPIENTS OF THIS DOCUMENT ARE INVITED TO SUBMIT,WITH THEIR COMMENTS,NOTIFICATION OF ANY RELEVANT PATENT RIGHTS OF WHICH THEY ARE AWARE AND TO PROVIDE SUPPORTING DOCUMENTATION.Titre:CEI 61970-301 Ed.4:Interface de programmation dapplication pour systme de gestion dnergie(EMS-API)Partie 301:Base de Modle dInformation Commun(CIM)Title:IEC 61970-301 Ed.4:Energy Management System Application Program Interface(EMS-API)Part 301:Common Information Model(CIM)Base Note dintroduction Introductory note ATTENTION VOTE PARALLLE CEI CENELEC Lattention des Comits nationaux de la CEI,membres du CENELEC,est attire sur le fait que ce projet de comit pour vote(CDV)de Norme internationale est soumis au vote parallle.Les membres du CENELEC sont invits voter via le systme de vote en ligne du CENELEC.ATTENTION IEC CENELEC PARALLEL VOTING The attention of IEC National Committees,members of CENELEC,is drawn to the fact that this Committee Draft for Vote(CDV)for an International Standard is submitted for parallel voting.The CENELEC members are invited to vote through the CENELEC online voting system.Copyright 2011 International Electrotechnical Commission,IEC.All rights reserved.It is permitted to download this electronic file,to make a copy and to print out the content for the sole purpose of preparing National Committee positions.You may not copy or mirror the file or printed version of the document,or any part of it,for any other purpose without permission in writing from IEC.61970-301/CDV IEC(E)1 Draft IEC 61970:Energy Management System Application Program Interface(EMS-API)Part 301:Common Information Model(CIM)Base Revision 024 Based on release IEC61970CIM14v15 2 61970-301/CDV IEC(E)CONTENTS FOREWORD.18 INTRODUCTION.20 1 Scope.22 2 Normative references.22 3 Terms and definitions.23 3.1 Terms and definitions overview.23 4 CIM specification.23 4.1 CIM modeling notation.23 4.2 CIM packages.23 4.3 CIM classes and relationships.25 4.3.1 Classes.25 4.3.2 Generalization.26 4.3.3 Simple association.27 4.3.4 Aggregation.28 4.4 CIM model concepts and examples.28 4.4.1 Concepts.28 4.4.2 Containment,equipment hierarchies and naming.28 4.4.3 Connectivity model.31 4.4.4 Inheritance hierarchy.34 4.4.5 Transformer model.36 4.4.6 Regulating transformer modeling.37 4.4.7 Measurements and controls.40 4.4.8 Regulating control models.45 4.5 Modeling guidelines.45 4.5.1 Modeling for change.45 4.5.2 Process for amendments to the CIM.46 4.5.3 Changes to the CIM UML model.46 4.5.4 Changes to the CIM standards documents.46 4.5.5 CIM profiles.46 4.6 Modeling tools.47 4.7 User implementation conventions.47 4.7.1 Conventions beyond UML.47 4.7.2 Number of Terminals for ConductingEquipment objects.47 4.8 CIM modeling examples.47 5 Detailed model.48 5.1 Overview.48 5.2 Context.48 6 Package architecture(normative).49 6.1 Top package IEC61970.49 6.1.1 General.49 6.1.2 IEC61970CIMVersion root class.50 6.1.3 Package Domain.51 6.1.4 Package Core.70 6.1.5 Package OperationalLimits.97 6.1.6 Package Topology.104 6.1.7 Package Wires.111 61970-301/CDV IEC(E)3 6.1.8 Package Generation.174 6.1.9 Package LoadModel.236 6.1.10 Package Outage.250 6.1.11 Package Protection.254 6.1.12 Package Equivalents.260 6.1.13 Package Meas.266 6.1.14 Package SCADA.291 6.1.15 Package ControlArea.296 6.1.16 Package Contingency.302 6.1.17 Package StateVariables.304 Bibliography.310 Figure 1 CIM IEC 61970-301 package diagram.25 Figure 2 Example of generalization.27 Figure 3 Example of simple association.28 Figure 4 Example of aggregation.28 Figure 5 Equipment containers.30 Figure

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开