分享
IEC_62271-206_Ed._1.0.pdf
下载文档

ID:233932

大小:212.75KB

页数:24页

格式:PDF

时间:2023-03-14

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
IEC_62271 206 _Ed _1
FORM FDIS(IEC)/FORMULAIRE FDIS(CEI)2009-01-09 Registered trademark of the International Electrotechnical Commission 17C/491/FDISFINAL DRAFT INTERNATIONAL STANDARDPROJET FINAL DE NORME INTERNATIONALEProject number Numro de projet IEC 62271-206 Ed.1.0 IEC/TC or SC CEI/CE ou SC SC 17C Secretariat/Secrtariat Germany Submitted for parallel voting in CENELEC Soumis au vote parallle au CENELEC Distributed on/Diffus le 2010-10-01 Voting terminates on/Vote clos le 2010-12-03 Also of interest to the following committees Intresse galement les comits suivants SC 17A Supersedes document Remplace le document 17C/457/CDV,17C/484/RVC Horizontal standard Norme horizontale Other TC/SCs are requested to indicate their interest,if any,in this FDIS to the TC/SC secretary Les autres CE/SC sont requis dindiquer leur intrt,si ncessaire,dans ce FDIS lintention du secrtaire du CE/SC Functions concerned Fonctions concernes Safety Scurit EMC CEM Environment Environnement Quality assurance Assurance de la qualit CE DOCUMENT EST UN PROJET DIFFUS POUR APPROBATION.IL NE PEUT TRE CIT COMME NORME INTERNATIONALE AVANT SA PUBLICATION EN TANT QUE TELLE.OUTRE LE FAIT DTRE EXAMINS POUR TABLIR SILS SONT ACCEPTABLES DES FINS INDUSTRIELLES,TECHNOLOGIQUES ET COMMERCIALES,AINSI QUE DU POINT DE VUE DES UTILISATEURS,LES PROJETS FINAUX DE NORMES INTERNATIONALES DOIVENT PARFOIS TRE EXAMINS EN VUE DE LEUR POSSIBILIT DE DEVENIR DES NORMES POUVANT SERVIR DE RFRENCE DANS LES RGLEMENTATIONS NATIONALES.LES RCIPIENDAIRES DU PRSENT DOCUMENT SONT INVITS PRSENTER,AVEC LEURS OBSERVATIONS,LA NOTIFICATION DES DROITS DE PROPRIT DONT ILS AURAIENT VENTUELLEMENT CONNAISSANCE ET FOURNIR UNE DOCUMENTATION EXPLICATIVE.THIS DOCUMENT IS A DRAFT DISTRIBUTED FOR APPROVAL.IT MAY NOT BE REFERRED TO AS AN INTERNATIONAL STANDARD UNTIL PUBLISHED AS SUCH.IN ADDITION TO THEIR EVALUATION AS BEING ACCEPTABLE FOR INDUSTRIAL,TECHNOLOGICAL,COMMERCIAL AND USER PURPOSES,FINAL DRAFT INTERNATIONAL STANDARDS MAY ON OCCASION HAVE TO BE CONSIDERED IN THE LIGHT OF THEIR POTENTIAL TO BECOME STANDARDS TO WHICH REFERENCE MAY BE MADE IN NATIONAL REGULATIONS.RECIPIENTS OF THIS DOCUMENT ARE INVITED TO SUBMIT,WITH THEIR COMMENTS,NOTIFICATION OF ANY RELEVANT PATENT RIGHTS OF WHICH THEY ARE AWARE AND TO PROVIDE SUPPORTING DOCUMENTATION.Titre Appareillages a haute tension-Partie 206:Systmes indicateurs de prsence de tension Title High-voltage switchgear and controlgear-Part 206:Voltage presence indicating systems ATTENTION VOTE PARALLLE CEI CENELEC Lattention des Comits nationaux de la CEI,membres du CENELEC,est attire sur le fait que ce projet finale de Norme internationale est soumis au vote parallle.Les membres du CENELEC sont invits voter via le systme de vote en ligne du CENELEC.ATTENTION IEC CENELEC PARALLEL VOTING The attention of IEC National Committees,members of CENELEC,is drawn to the fact that this final draft International Standard(DIS)is submitted for parallel voting.The CENELEC members are invited to vote through the CENELEC online voting system.Copyright 2010 International Electrotechnical Commission,IEC.All rights reserved.It is permitted to download this electronic file,to make a copy and to print out the content for the sole purpose of preparing National Committee positions.You may not copy or mirror the file or printed version of the document,or any part of it,for any other purpose without permission in writing from IEC.2 62271-206/FDIS IEC CONTENTS FOREWORD.5 1 Scope.7 2 Normative references.7 3 Terms and definitions.8 4 Service conditions.8 5 Ratings.8 5.1 Rated voltage.9 5.2 Rated insulation level.9 5.3 Rated frequency.9 6 Design and construction.9 6.1 General.9 6.1.1 Parts of VPIS.9 6.1.2 Phase comparison.9 6.1.3 Degree of protection(IP code).9 6.1.4 Impact resistance.9 6.1.5 Testing element.9 6.2 Threshold values for voltage presence indication.10 6.3 Indication and perceptibility.10 6.3.1 General.10 6.3.2 Frequency of repetition.10 6.3.3 Response time.10 6.3.4 Indication until power source is exhausted.10 6.4 Coupling element and voltage limiting device.10 6.4.1 Insulation of coupling element.10 6.4.2 Voltage limiting device.11 6.4.3 Threshold voltage of voltage limiting device.11 6.4.4 Earth fault conditions.11 6.4.5 Maximum current delivered by the connecting point.11 6.5 Marking.11 6.6 Phase comparator and connecting point.12 6.6.1 General.12 6.6.2 Clear indication of phase comparators.12 6.6.3 Perceptibility of indication.12 6.6.4 Indication in case of absence of voltage on one side.12 6.6.5 Indication in case of absence of voltage on both sides.12 6.7 Electromagnetic compatibility(EMC).12 7 Type tests.13 7.1 General.13 7.1.1 Sequence of tests.13 7.1.2 Test specimens.13 7.1.3 Conditioning procedure.13 7.1.4 Test voltages.13 7.1.5 Test conditions.13 7.1.6 Values of currents and voltages.14 7.1.7 Tolerances.14 7.2 Arrangement,assembly,marking,and instructions for use.14 62271-206/FDIS IEC 3 7.3 Clear indication of VPIS.14 7.4 Response time of VPIS.14 7.5 Dielectric strength of th

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开