温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
IEC_60118
1983
_amd1
1994
_scan
NORME?CEIINTERNATIONALE?IECINTERNATIONAL?118-0STANDARD?1983AMENDEMENT 1AMENDMENT 11994-01Amendement 1Appareils de correction auditivePartie zro:Mthodes de mesure des caractristiqueslectroacoustiquesAmendment 1Hearing aidsPart 0:Measurement of electroacousticalcharacteristics CEI 1994 Droits de reproduction rservs Copyright all rights reservedBureau Central de la Commission Electrotechnique Internationale 3,rue de Varemb Genve,SuisseIECCommission Electrotechnique Internationale CODE PRIXInternational Electrotechnical Commission PRICE CODEMetssyHapowiaH 3nenTpoTeXHH4ecKaR HOMHCCHRPour prix,voir catalogue en vigueurFor price,see current catalogueLICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.DIS29(BC)169Rapport de vote29(BC)206-2-?118-0 amend.1 CEI:1994AVANT-PROPOSLe prsent amendement a t tabli par le comit dtudes 29 de la CEI:Electroacoustique.Le texte de cet amendement est issu des documents suivants:Le rapport de vote indiqu dans le tableau ci-dessus donne toute information sur le voteayant abouti lapprobation de cet amendement.Page 12Dans larticle 3.3,dernire ligne,remplacer 4.9 par 4.4.Page 16Remplacer larticle 4.17 par le suivant:4.17 Position de la commande de gain de test de rfrenceLe rglage de la commande de gain de lappareil de correction auditive qui produit un niveaude pression acoustique de sortie dans le simulateur doreilles de 15 1 dB infrieur OSPL90 pour un niveau de pression acoustique dentre de 60 dB la frquence de testde rfrence.Si le gain disponible ne permet pas ceci dans une marge dau moins 7 dB,une position de la commande de gain de 7 dB en dessous du gain maximum lafrquence dessai de rfrence doit tre utilise.La position de la commande de gain doittre indique dans le procs verbal de mesures.Page 20Dans le paragraphe 5.4.6,dernire ligne,remplacer 6.4.5 par 6.4.4.LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.DIS29(CO)169Report on voting29(CO)206118-0 Amend.1 I EC:1994?3FOREWORDThis amendment has been prepared by!EC technical committee 29:Electroacoustics.The text of this amendment is based on the following documents:Full information on the voting for the approval of this amendment can be found in thereport on voting indicated in the above table.Page 13In clause 3.3,last line,replace 4.9 by 4.4.Page 17Replace clause 4.17 by the following:4.17 Reference test gain control positionThe setting of the hearing aid gain control which provided an output sound pressure levelin the ear simulator of 15 1 dB less than OSPL90 for an input sound pressure levelof 60 dB at the reference test frequency.If the gain available will not permit this by amargin of at least 7 dB,a gain control position corresponding to a gain of 7 dB below full-ongain at the reference test frequency shall be used.The gain control position shall bestated in the measurement report.Page 21In subclause 5.4.6,last line,replace 6.4.5 by 6.4.4.LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.ICS 17.140.50Typeset and printed by the IEC Central OfficeGENEVA,SWITZERLANDLICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.