温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
IEC_60642
1979
_amd1
1992
_scan
NORME?CEIINTERNATIONALE?IECINTERNATIONAL?642STANDARD?1979AMENDEMENT 1AMENDMENT 11992-09Amendement 1Rsonateurs et dispositifs en cramiquepizolectrique pour la commande etle choix de la frquenceChapitre I:Valeurs et conditions normalisesChapitre II:Conditions de mesure et dessaisAmendment 1Piezoelectric ceramic resonators andresonator units for frequency controland selectionChapter I:Standard values and conditionsChapter II:Measuring and test conditions CEI 1992 Droits de reproduction rservs Copyright all rights reservedBureau central de la Commission Electrotechnique Internationale 3,rue de Varemb Genve SuisseIECCommission Electrotechnique Internationale CODE PRIX?CInternational Electrotechnical Commission PRICE CODEMe,ipvHapoiman 3neKTpoTeXHH4eCHap HoMHCCHR?Pour prix,voir catalogue en vigueurFor price,see current catalogueLICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.DIS49(BC)220Rapport de vote49(BC)235-2-?642 amend.1 CEIAVANT-PROPOSLe prsent amendement a t tabli par le comit dtudes n 49 de la CEI:Dispositifspizolectriques et dilectriques pour la commande et le choix de la frquence.Le texte de cet amendement est issu des documents suivants:Le rapport de vote indiqu dans le tableau ci-dessus donne toute information sur le voteayant abouti lapprobation de cet amendement.Page 48Annexe BMthodes normalises de mesure des rsonateursen cramique pizolectrique et dispositifs encramique pizolectriqueRemplacer A ltude par le texte suivant:B1 Principe de la mesureCe principe est bas sur le mme principe que celui qui est dcrit dans la CEI 302 et laCEI 444.B2 Circuit de mesureIl se compose essentiellement dun circuit en Ir reli par le montage dessai deux portesaux appareils associs.La gamme de frquence doit tre de 10 kHz 30 MHz.B3 Spcifications mcaniquesLe montage dessai typique pour les rsonateurs en cramique pizolectrique se com-pose des lments suivants(voir figure B.1):a)deux plaques isolantes;b)deux cales dpaisseur mtalliques;c)deux plaques mtalliques argentes;d)contact argent fix;e)contact argent variable;f)ressort en bar argent.LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.DIS49(CO)220Report on Voting49(CO)235642 Amend.1 IEC?-3-FOREWORDThis amendment has been prepared by IEC technical committee No.49:Piezoelectric anddielectric devices for frequency control and selection.The text of this amendment is based on the following documents:Full information on the voting for the approval of this amendment can be found in thevoting report indicated in the above table.Page 49Annex BStandard methods of measurement for piezoelectricceramic resonators and resonator unitsReplace Under consideration by the following text:B1 Principle of measurementThis principle is based on the same principle as that written in IEC 302 and IEC 444.B2 Measuring circuitThis consists basically of a n-network connected with a two-terminal test fixture to theassociated equipment.The frequency range shall be 10 kHz to 30 MHz.B3 Mechanical specificationA typical test fixture for piezoelectric ceramic resonators consists of the following parts(see figure B.1):a)two insulating plates;b)two metal spacers;c)two silver-plated metal plates;d)silver-plated fixed contact;e)silver-plated variable contact;f)silver-plated bar spring.LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.CEI 93919220-4-?642 amend.1 CEI20Dimensions en millimtresFigure B.1-Montage dessai des rsonateursB4 Rsistances de rfrenceLes rsistances utilises pour ltalonnage ont la forme indique ci-dessous(voir figureB.2).Les valeurs de rsistances pour ltalonnage initial sont 50 S2 et 100 a.120IElectrode en argentSubstrat en Al2030,5?,.,-,-:-Rsistance mtallique normalise CE!940192 Dimensions en millimtresFigure B.2-Rsistances pour ltalonnageLICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU./EC 939/9220120642 Amend.1 IEC26-5-16LAJT101020 42.514?I?1470,5Dimensions in millimetresFigure B.1-Test fixture for resonatorsB4 Reference resistorsThe resistors for the calibration are of the shape shown below(see figure B.2).Resistancevalues for initial calibration are 50 D.and 100 O.rSilver electrodeAI2O3 substrateStandard metal resistor0,5?/EC 940/92Dimensions in millimetresFigure B.2-Resistors for calibrationLICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.ICS 31.140Typeset and printed by the IEC Central OfficeGENEVA,SWITZERLANDLICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.