温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
IEC_60838
1994
_amd2
2004
NORME INTERNATIONALE CEIIEC INTERNATIONAL STANDARD 60838-2-11994AMENDEMENT 2AMENDMENT 22004-10 Amendement 2 Douilles diverses pour lampes Partie 2-1:Rgles particulires Douilles S14 Amendment 2 Miscellaneous lampholders Part 2-1:Particular requirements Lampholders S14 Pour prix,voir catalogue en vigueur For price,see current catalogue IEC 2004 Droits de reproduction rservs Copyright-all rights reserved International Electrotechnical Commission,3,rue de Varemb,PO Box 131,CH-1211 Geneva 20,SwitzerlandTelephone:+41 22 919 02 11 Telefax:+41 22 919 03 00 E-mail:inmailiec.ch Web:www.iec.ch Commission Electrotechnique InternationaleInternational Electrotechnical Commission B CODE PRIX PRICE CODE LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.2 60838-2-1 amend.2 CEI:2004 AVANT-PROPOS Le prsent amendement a t tabli par le sous-comit 34B:Culots et douillles,du comit dtudes 34 de la CEI:Lampes et quipements associs.Le texte de cet amendement est issu des documents suivants:FDIS Rapport de vote 34B/1153/FDIS 34B/1172/RVD Le rapport de vote indiqu dans le tableau ci-dessus donne toute information sur le vote ayant abouti lapprobation de cet amendement.Le comit a dcid que le contenu de cette publication ne sera pas modifi avant la date de maintenance indique sur le site web de la CEI sous http:/webstore.iec.ch dans les donnes relatives la publication recherche.A cette date,la publication sera reconduite;supprime;remplace par une dition rvise,ou amende._ Page 12 16 Lignes de fuite et distances dans lair Remplacer les paragraphes 16.2 et 16.3 existants par ce qui suit:16.2 La distance dans lair entre les parties actives de la douille et les parties mtalliques accessibles du culot ne doit pas tre infrieure 1,5 mm.NOTE Au Japon,la distance minimale est de 1,7 mm.16.3 Pour les ressorts mtalliques de rtention qui ne sont pas recouverts,une distance dans lair minimale de 3 mm par rapport la surface dappui est requise._ LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.60838-2-1 Amend.2 IEC:2004 3 FOREWORD This amendment has been prepared by subcommittee 34B:Lamp caps and holders,of IEC technical committee 34:Lamps and related equipment.The text of this amendment is based on the following documents:FDIS Report on voting 34B/1153/FDIS 34B/1172/RVD Full information on the voting for the approval of this amendment can be found in the report on voting indicated in the above table.The committee has decided that the contents of this amendment and the base publication will remain unchanged until the maintenance result date indicated on the IEC web site under http:/webstore.iec.ch in the data related to the specific publication.At this date,the publication will be reconfirmed,withdrawn,replaced by a revised edition,or amended._ Page 13 16 Creepage distances and clearances Replace existing subclauses 16.2 and 16.3 by the following:16.2 The clearance between live parts of the lampholder and accessible metal parts of the cap shall not be less than 1,5 mm.NOTE For Japan,the minimum distance is 1,7 mm 16.3 For metal retention springs which are not covered,a minimum clearance of 3 mm to the mounting surface is required._ LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.ISBN 2-8318-7674-5-:HSMINB=YU:ICS 29.140.10 Typeset and printed by the IEC Central Office GENEVA,SWITZERLAND LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.