温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
IEC_61000
15
2010
_ISH1
2017
IEC 61000-4-15:2010/ISH1:2017 1 IEC 2017 ICS 33.100.20 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ IEC 61000-4-15 Edition 2.0 2010-08 ELECTROMAGNETIC COMPATIBILITY(EMC)Part 4-15:Testing and measurement techniques Flickermeter Functional and design specifications I N T E R P R E T A T I O N S H E E T 1 This interpretation sheet has been prepared by subcommittee 77A:EMC Low frequency phenomena,of IEC technical committee 77:Electromagnetic compatibility.The text of this interpretation sheet is based on the following documents:FDIS Report on voting 77A/966/FDIS 77A/973/RVD Full information on the voting for the approval of this interpretation sheet can be found in the report on voting indicated in the above table._ Interpretation of requirements for rectangular voltage modulation with duty ratio according to IEC 61000-4-15:Electromagnetic compatibility(EMC)Testing and measurement techniques Flickermeter Functional and design specifications.IEC 61000-4-15 Ed 2 gives requirements in 6.8 for what is called“Rectangular voltage changes with 20%duty cycle”.Table 11 provides the test specification for rectangular voltage changes with duty ratio.The requirements per Table 11 and the associated tests patterns caused some questions in the past year,and therefore IEC/SC77A/WG-2 wishes to clarify the title and interpretation per 6.8 which should be read as follows:6.8 Rectangular voltage modulation for 20%of the time The amplitude of the test voltage U is rectangularly modulated with a 50%duty cycle at 28 Hz.Every minute the amplitude modulation is switched on for 12 s and off for 48 s.Table 11 specifies the modulation depth in terms of voltage fluctuation(U/U),which is further specified in Annex B.The transition time at the edges of the rectangular modulation shall be less than 0,5 ms.The ten-minute Pst indication of the meter under test shall be 1,00 with a tolerance of 5%.Figure 1 shows a U/U=35%for illustration purposes,as a 1%to 2%modulation would not be visible.Only 400 ms of the time axis is depicted,showing 200 ms on each side of the modulation on/off switching at 12 s.NOTE The above text in 6.8 will be considered as a replacement for the original text when IEC 61000-4-15 is updated either through an amendment or replaced by a new edition._ IEC 61000-4-15:2010-08/ISH1:2017-08(en)