温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
IEC_60838
1994
_amd1
1998
NORMEINTERNATIONALECEIIECINTERNATIONALSTANDARD60838-2-11994AMENDEMENT 1AMENDMENT 11998-06Amendement 1Douilles diverses pour lampes Partie 2:Rgles particulires Section 1:Douilles S14Amendment 1Miscellaneous lampholders Part 2:Particular requirements Section 1:Lampholders S14BPour prix,voir catalogue en vigueurFor price,see current catalogueCODE PRIXPRICE CODE IEC 1998 Droits de reproduction rservs Copyright-all rights reservedInternational Electrotechnical Commission3,rue de Varemb Geneva,SwitzerlandTelefax:+41 22 919 0300 e-mail:inmailiec.chIEC web site http:/www.iec.ch Commission Electrotechnique Internationale International Electrotechnical CommissionLICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.2 60838-2-1 amend.1 CEI:1998AVANT-PROPOSLe prsent amendement a t tabli par le sous-comit 34B:Culots et douilles,du comitdtudes 34 de la CEI:Lampes et quipements associs.Le texte de cet amendement est issu des documents suivants:FDISRapport de vote34B/779/FDIS34B/781/RVDLe rapport de vote indiqu dans le tableau ci-dessus donne toute information sur le vote ayantabouti lapprobation de cet amendement._Page 1012 Douilles interrupteursAjouter le nouveau texte suivant aprs la note de 12.5,la page 12:Les interrupteurs qui ont uniquement pour fonction dassurer la protection contre les chocslectriques lors de linstallation ou de lenlvement de la lampe doivent tre actionns de faonnormale pendant 1 000 mouvements de commutation une frquence de 30 oprations parminute._LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.60838-2-1 Amend.1 IEC:1998 3 FOREWORDThis amendment has been prepared by subcommittee 34B:Lamp caps and holders,of IECtechnical committee 34:Lamps and related equipment.The text of this amendment is based on the following documents:FDISReport on voting34B/779/FDIS34B/781/RVDFull information on the voting for approval of this amendment can be found in the report onvoting indicated in the above table._Page 1112 Switched lampholdersAdd the following new text after the note in 12.5 on page 13:Switches which only have the function to provide protection against electric shock duringinsertion or removal of the lamp shall be operated in a normal manner for 1 000 switchmovements at a rate of 30 movements per minute._LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.ISBN 2-8318-4432-0?&1+,?;7765?ICS 29.140.10Typeset and printed by the IEC Central OfficeGENEVA,SWITZERLANDLICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.