温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
IEC_60851
1996
_amd1
2003
NORMEINTERNATIONALECEIIECINTERNATIONALSTANDARD60851-11996-10AMENDEMENT 1AMENDMENT 12003-12Amendement 1Fils de bobinage Mthodes dessai Partie 1:GnralitsAmendment 1Winding wires Test methods Part 1:GeneralPour prix,voir catalogue en vigueurFor price,see current catalogue IEC 2003 Droits de reproduction rservs Copyright-all rights reservedInternational Electrotechnical Commission,3,rue de Varemb,PO Box 131,CH-1211 Geneva 20,SwitzerlandTelephone:+41 22 919 02 11 Telefax:+41 22 919 03 00 E-mail:inmailiec.ch Web:www.iec.chCommission Electrotechnique InternationaleInternational Electrotechnical Commission DCODE PRIXPRICE CODELICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.2 60851-1 Amend.1 CEI:2003AVANT-PROPOSLe prsent amendement a t tabli par le comit dtudes 55 de la CEI:Fils de bobinage.Le texte de cet amendement est issu des documents suivants:FDISRapport de vote55/873/FDIS55/890/RVDLe rapport de vote indiqu dans le tableau ci-dessus donne toute information sur le vote ayantabouti lapprobation de cet amendement.Le comit a dcid que le contenu de la publication de base et de ses amendements ne serapas modifi avant 2009.A cette date,la publication serareconduite;supprime;remplace par une dition rvise,ouamende._Partout dans le texte,ajouter 60000 aux numros des normes cites.Par exemple,changer CEI 851 en CEI 60851.Page 4INTRODUCTIONRemplacer le texte existant par ce qui suit:Cette norme constitue lun des lments dune srie traitant des fils isols utiliss dans lesenroulements des appareils lectriques.Cette srie comporte trois groupes dfinissantrespectivement:1)les fils de bobinage Mthodes dessai(CEI 60851);2)les spcifications pour types particuliers de fils de bobinage(CEI 60317);3)le conditionnement de fils de bobinage(CEI 60264).LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.60851-1 Amend.1 IEC:2003 3 FOREWORDThis amendment has been prepared by IEC technical committee 55:Winding wires.The text of this amendment is based on the following documents:FDISReport on voting55/873/FDIS55/890/RVDFull information on the voting for the approval of this amendment can be found in the reporton voting indicated in the above table.The committee has decided that the contents of the base publication and its amendments willremain unchanged until 2009.At this date,the publication will bereconfirmed;withdrawn;replaced by a revised edition,oramended._Throughout the text,add 60000 to the numbers of the standards cited.For example,change“IEC 851”to“IEC 60851”.Page 5INTRODUCTIONReplace the existing text with the following:This standard is one of a series which deals with insulated wires used for windings inelectrical equipment.The series comprises three groups:1)winding wires Test methods(IEC 60851);2)specifications for particular types of winding wires(IEC 60317);3)packaging of winding wires(IEC 60264).LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.4 60851-1 Amend.1 CEI:2003Page 12Annexe APartie 3:Proprits mcaniquesRemplacer,la page 14,“5.5.4 Fil de section circulaire ou rectangulaire recouvert dunruban“par le texte suivant:5.5.4 Fil de section circulaire ou rectangulaire recouvert dun ruban(uniquement pour rubanadhsif)Remplacer le titre de lEssai 18 par le nouveau titre suivant:7 Essai 18 :Thermo-adhrence(applicable au fil de section circulaire maill de diamtrenominal de conducteur suprieur 0,050 mm jusqu 2,000 mm inclus)Ajouter,aprs la rfrence lAnnexe A,ce qui suit:Annexe B Friction,mthode dessaisPartie 4:Proprits chimiquesPage 16Remplacer le titre et le texte de lEssai 20 comme suit:6 Essai 20 :Rsistance lhydrolyse et lhuile de transformateur(applicable au fil debobinage maill)6.1 Fil de section circulaire6.2 Fil de section rectangulairePartie 5:Proprits lectriquesDans lEssai 13:Tension de claquage,modifier le titre de 4.6 et ajouter 4.7 comme suit:4.6 Fil rond guip de fibre4.7 Fil de section rectangulaireLICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.60851-1 Amend.1 IEC:2003 5 Page 13Annex APart 3:Mechanical propertiesReplace,on page 15,“5.5.4 Tape wrapped round and rectangular wire”with the following text:5.5.4 Tape wrapped round and rectangular wire(only for adhesive tape)Replace the title of Test 18 with the following new title:7 Test 18*:Heat bonding(applicable to enamelled round wire with a nominal conductordiameter over 0,050 mm up to and including 2,000 mm)Add,after the reference to Annex A,the following:Annex B Friction test methodsPart 4:Chemical propertiesPage 17Replace the title and the text of Test 20 as follows:6 Test 20*:Resistance to hydrolysis and to transformer oil(applicable to enamelledwire)6.1 Round wire6.2 Rectangular wirePart 5:Electrical propertiesIn Test 13:Breakdown voltage,change the title of 4.6 and add 4.7 as follows:4.6 Fibre wound round wire4.7 Rec