分享
IEC_60216-5-2008_cor1-2009.pdf
下载文档

ID:227674

大小:97.50KB

页数:3页

格式:PDF

时间:2023-03-14

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
IEC_60216 2008 _cor1 2009
December 2009 Dcembre 2009 IEC 60216-5(Third edition 2008)Electrical insulating materials Thermal endurance properties Part 5:Determination of relative thermal endurance index(RTE)of an insulating material CEI 60216-5(Troisime dition 2008)Matriaux isolants lectriques Proprits dendurance thermique Partie 5:Dtermination de lindice dendurance thermique relatif(RTE)dun matriau isolant C O R R I G E N D U M 1 Add the attached software supplement(which is referred to in Annex C).Annex C Replace Annex C by the following new Annex:C.1 Computer programs for IEC 60216-5:2008(RTE)C.1.1 General The standard is accompanied by a CDROM.This CDROM contains three programs for calculation of the Relative Thermal Endurance Index of an insulating material,from data in accordance with IEC 60216-1 and 60216-3.It also contains a pair of data files for trial purposes.All programs are supplied as source code,suitable for Microsoft Quick Basic 4.5 or Professional Basic v.7(to enable use with Visual Basic,considerable editing will probably be required)and as executable program files to run in a DOS window under any variety of Windows.For optimum performance,the DOS window should be full screen.C.1.2 Entry.exe and Entry.bas This is identical to the data entry file supplied in an annex of IEC 60216-3.A separate set of data is required for each material,Control and Candidate.Ajouter le supplment informatique ci-joint(dont il est fait rfrence en Annexe C).Annexe C Remplacer lAnnexe C par la nouvelle Annexe suivante:C.1 Programmes informatiques pour la CEI 60216-5:2008(RTE)C.1.1 Gnralits La prsente norme est accompagne dun CDROM.Ce CDROM contient trois programmes pour excuter les calculs de lindice dendurance thermique relatif(RTE)dun matriau isolant,partir de donnes conformes la CEI 60216-1 et la CEI 60216-3.Il contient en plus,deux fichiers de donnes pour essayer le programme.Tous les programmes sont fournis en code source,utilisables avec Microsoft Quick Basic 4.5 ou Professional Basic v.7(leur utilisation en Visual Basic demandera certainement une importante rvision)et sous forme de programmes excutables sous DOS-window dans toutes les versions de Windows.Pour une performance optimale,il convient dutiliser la fentre DOS-window couvrant tout lcran.C.1.2 Entry.exe and Entry.bas Ceci est identique au fichier des donnes analyser fourni dans une annexe de la CEI 60216-3.Un ensemble spar de donnes Control et Candidate est requis for chaque matriau.LICENSED TO MECON LIMITED-RANCHI/BANGALORE,FOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.December 2009 Dcembre 2009 C.1.3 IEC 216-5.exe and IEC 216-5.bas This program is an enhanced version of the program supplied in an annex of IEC 60216-3.It has been enhanced by addition of a procedure to record to a data file the intermediate data required for calculation of RTE.When the experimental data are processed,the intermediate data are automatically saved to a file with the same name as the experimental data file and the ending“.int”.For example,a data file n3.dst of destructive test data would generate an intermediate file n3.int.The thermal endurance graph is drawn to screen for each material,and the statistical test results are reported.C.1.4 RTE.exe and RTE.bas This program requests the intermediate data files for Control and Candidate,and performs the calculations of IEC 60216-5,giving the RTE and its confidence interval,the halving intervals of both materials(HIC),the correlation time and the ratio of the correlation time to the longest time-to-endpoint(extrapolation).These values are required for the purposes of 6.1 and 6.2 of the standard.C.2 Data file structure C.2.1 Experimental data The structure of these files is explained in IEC 60216-3.C.2.2 Intermediate data The following values are recorded,one to each line in the file,which is a simple ASCII text file.General mean of x-values(reciprocal Kelvin temperatures):x 2nd moment(sample variance)of x-values:()x2 General mean of y-values(logarithm of time values):y C.1.3 IEC 216-5.exe et IEC 216-5.bas Ce programme est une version amliore du programme fourni dans une annexe de la CEI 60216-3.Il a t amlior par lajout dune procdure denregistrement dans un fichier de donnes des valeurs intermdiaires ncessaires au calcul du RTE.Lorsque les valeurs exprimentales sont calcules,les valeurs intermdiaires sont automatiquement sauvegardes dans un fichier qui porte le mme nom que le fichier des donnes exprimentales avec le suffixe .int.Par exemple,un fichier de donnes n3.dst de lessai destructif gnrera un fichier intermdiaire n3.int.Le graphique dendurance thermique apparat lcran pour chaque matriau,et les rsultats de lessai statistique sont affichs.C.1.4 RTE.exe et RTE.bas Ce programme ncessite les fichiers intermdiaires de donnes pour Control et Candidate et effectue les calculs de la CEI 60216-5 donnant le RTE et son intervalle de confiance,les intervalles de division des deux matriaux (HIC),le temps de corrlation et le rapport ent

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开