分享
IEC_60055-2-1981_amd2-2005.pdf
下载文档

ID:227529

大小:1.46MB

页数:62页

格式:PDF

时间:2023-03-14

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
IEC_60055 1981 _amd2 2005
NORME INTERNATIONALE CEIIEC INTERNATIONAL STANDARD 60055-21981AMENDEMENT 2AMENDMENT 22005-02 Amendement 2 Cbles isols au papier imprgn sous gaine mtallique pour des tensions assignes infrieures ou gales 18/30 kV(avec mes conductrices en cuivre ou aluminium et lexclusion des cbles pression de gaz et huile fluide)Partie 2:Gnralits et exigences de construction Amendment 2 Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV(with copper or aluminium conductors and excluding gas-pressure and oil-filled cables)Part 2:General and construction requirements Pour prix,voir catalogue en vigueur For price,see current catalogue IEC 2005 Droits de reproduction rservs Copyright-all rights reserved International Electrotechnical Commission,3,rue de Varemb,PO Box 131,CH-1211 Geneva 20,SwitzerlandTelephone:+41 22 919 02 11 Telefax:+41 22 919 03 00 E-mail:inmailiec.ch Web:www.iec.ch Commission Electrotechnique InternationaleInternational Electrotechnical Commission V CODE PRIX PRICE CODE LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.2 60055-2 Amend.2 CEI:2005 AVANT-PROPOS Cet amendement a t prpar par le comit dtudes 20 de la CEI:Cbles lectriques.Le texte de cet amendement est issu des documents suivants:FDIS Rapport de vote 20/742/FDIS 20/753/RVD Le rapport de vote indiqu dans le tableau ci-dessus donne toute information sur le vote ayant abouti lapprobation de cet amendement.Le comit a dcid que le contenu de cet amendement et de la publication de base ne sera pas modifi avant la date de maintenance indique sur le site web de la CEI sous http:/webstore.iec.ch dans les donnes relatives la publication recherche.A cette date,la publication sera reconduite,supprime,remplace par une dition rvise,ou amende._ Page 8 1.2 Tempratures maximales admissibles en service Remplacer le texte de la note 1 sous le tableau par ce qui suit:Les tempratures donnes dans ce tableau ne sont valables que pour des cbles installs en position sensiblement horizontale(sauf pour imprgnation non migrante).Les courants admissibles en rgime permanent bass sur ces tempratures sont donns lannexe C pour information.Page 74 Ajouter la nouvelle annexe C comme suit:LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.60055-2 Amend.2 IEC:2005 3 FOREWORD This amendment has been prepared by IEC technical committee 20:Electric cables.The text of this amendment is based on the following documents:FDIS Report on voting 20/742/FDIS 20/753/RVD Full information on the voting for the approval of this amendment can be found in the report on voting indicated in the above table.The committee has decided that the contents of this amendment and the base publication will remain unchanged until the maintenance result date indicated on the IEC web site under http:/webstore.iec.ch in the data related to the specific publication.At this date,the publication will be reconfirmed,withdrawn,replaced by a revised edition,or amended._ Page 9 1.2 Maximum permissible operating temperatures Replace the text of note 1 after the table by the following:The temperatures given in this table are only for cables installed in a substantially horizontal position(unless the impregnation is of the non-draining type).Steady-state continuous current ratings based on these temperatures are given in appendix C for information.Page 75 Add the following new appendix C as follows:LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.4 60055-2 Amend.2 CEI:2005 Annexe C Tableaux des courants admissibles en rgime permanent pour des cbles sous gaine de plomb pour des tensions entre 3,6/6 kV et 18/30 kV C.1 Gnralits C.1.1 Domaine dapplication Cette annexe,qui est pour information,traite uniquement des courants admissibles en rgime permanent des cbles isolation papier unipolaires et tripolaires sous gaine de plomb.Des tableaux des courants admissibles sont prsents pour les cbles unipolaires de tensions assignes de 3,6/6 kV 18/30 kV,pour les cbles tripolaires ceinture de tensions assignes de 3,6/6 kV et 6/10 kV,pour les cbles tripolaires champ radial de tensions assignes de 8,7/15 kV 18/30 kV et pour les cbles triplombs isols au papier imprgn de tensions assignes de 12/20 kV et 18/30 kV.Les tableaux de courants admissibles ont t calculs en faisant usage des mthodes de calcul exposes dans la CEI 60287.NOTE Pour les courants cycliques,voir la CEI 60853.Pour les limites de tempratures en cas de court-circuit,voir la CEI 60986.C.2 Construction des cbles Les constructions et les dimensions des cbles pour lesquelles les tableaux des courants admissibles ont t tablis sont celles donnes dans cette norme.Les constructions ou dimensions ne refltent pas des conceptions spcifiques dun fabricant,mais reprsentent des cbles modles.On considre que les cbles tripolaires ont une armure de fils dacier;les courants admissibles pour ces

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开