温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
IEC_60062
2016
_cor1
IEC 60062:2016/COR1:2016 1 IEC 2016 INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION LECTROTECHNIQUE INTERNATIONALE _ IEC 60062 Edition 6.0 2016-07 MARKING CODES FOR RESISTORS AND CAPACITORS IEC 60062 dition 6.0 2016-07 MARQUAGE DES CODES POUR RESISTANCES ET CONDENSATEURS C O R R I G E N D U M 1 CONTENTS Replace the entry for Annex B by the following entry:Annex X(informative)Cross-reference for references to the previous edition of this standard Replace the entry for Table B.1 by the following entry:Table X.1 Cross-reference to Clauses Replace the entry for Table B.2 by the following entry:Table X.2 Cross-reference to Tables 3.1 General rules Replace the 2nd paragraph by the following text:Wherever possible,the first band shall be the one nearest to the end of the resistor and the bands shall be so placed and spaced that there can be no confusion in reading the coding.Replace the 3rd paragraph by the following text and note:The design width of the band used for SOMMAIRE Remplacer lentre pour lAnnexe B par lentre suivante:Annexe X(informative)Correspondance des rfrences par rapport ldition prcdente de la prsente norme Remplacer lentre pour le Tableau B.1 par lentre suivante:Tableau X.1 Correspondances entre articles Remplacer lentre pour le Tableau B.2 par lentre suivante:Tableau X.2 Correspondances entre tableaux 3.1 Rgles gnrales Remplacer le deuxime alina par le texte suivant:Dans la mesure du possible,la premire bande doit tre celle qui se trouve le plus prs dune extrmit de la rsistance et les bandes doivent tre places et espaces de telle sorte quaucune confusion ne soit possible lors de la lecture du code.IEC 60062:2016-07/COR1:2016-12(en-fr)2 IEC 60062:2016/COR1:2016 IEC 2016 marking the tolerance shall be at least 1,5 times the width of the other bands in order to avoid any confusion.NOTE The design width is not intended to be measured.3.2 Prescription of code colours Replace the 2nd sentence by the following text:Complemented with the colours silver,gold and pink,they are also used for the coding of the multiplier,the tolerance and the temperature coefficient of resistance(TCR).Annex B Replace the annex title by:Annex X(informative)Cross-reference for references to the previous edition of this standard Replace the reference to“Table B.1”by:Table X.1 Replace the reference to“Table B.2”by:Table X.2 Table B.1 Replace the title of Table B.1 by:Table X.1 Cross-reference to Clauses Replace the header of the 2nd column by:IEC 60062:2016,6th edition Clause Table B.2 Replace the title of Table B.2 by:Table X.2 Cross-reference to Tables Remplacer le troisime alina par le texte et la note suivante:La largeur de la bande utilise pour marquer la tolrance doit tre dau moins 1,5 fois plus large que les autres pour viter toute confusion.NOTE La largeur de conception nest pas destine tre mesure.3.2 Prescription de couleurs de codage Remplacer la deuxime phrase par le texte suivant:Les couleurs argent,or et rose servent coder le facteur multiplicateur,la tolrance et le coefficient de temprature de rsistance(TCR).Annexe B Remplacer le titre de lannexe par:Annexe X(Informatif)Correspondance des rfrences par rapport ldition prcdente de la prsente norme Remplacer la rfrence Tableau B.1 par:Tableau X.1 Remplacer la rfrence Tableau B.2 par:Tableau X.2 Tableau B.1 Remplacer le titre du Tableau B.1 par:Tableau X.1 Correspondance entre articles Remplacer len-tte de la deuxime colonne par:IEC 60062:2016,6e dition Article IEC 60062:2016/COR1:2016 3 IEC 2016 Replace the header of the 2nd column by:IEC 60062:2016 6th edition Table Tableau B.2 Remplacer le titre du Tableau B.2 par:Tableau X.2 Correspondance entre tableaux Remplacer len-tte de la deuxime colonne par:IEC 60062:2016 6e dition Table