温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
DIN_IEC_61850
_E_2006
09
;.61850-6/CD1 IEC(E)2 57/798/CDCONTENTS1Scope.82Normative references.83Terms and definitions.94Abbreviations.95Intended engineering process with SCL.105.1General.105.2Scope of SCL.105.3Use of SCL in the Engineering process.116The SCL object model.126.1General.126.2The substation model.156.3The product(IED)model.166.4The communication system model.176.5Modelling of redundancy.187SCL description file types.188The SCL language.198.1Specification method.198.2SCL language extensions.218.3General structure.248.4Object and signal designation.259The SCL syntax elements.289.1Header.289.2Substation description.319.3IED description.449.4Communication system description.699.5Data type templates.75Annex A(normative)SCL syntax:XML schema definition.87A.1Base types.87A.2Substation syntax.99A.3Data type templates.103A.4IED capabilities and structure.106A.5Communication subnetworks.115A.6Main SCL.119Annex B(normative)SCL enumerations according to IEC 61850-7-3 and IEC 61850-7-4.120Annex C(informative)Syntax extension examples.126C.1Extension syntax for drawing layout coordinates.126CD1 2005 including Tissues1,2,3,4,5,6,8,9,10,12,14,15,16,17,18(partly),24,130,157,169,170,176,186,197,201This SCL version is backward compatible to the 2003 version with thefollowing constraints:-nameStructure=”FuncName”is no longer allowed-the options bufOvfl and segmentation of a report control block donot exist any more(were meaningless before)-the absence of the new ClientService capability element has to beinterpreted differently61850-6/CD1 IEC(E)3 57/798/CDC.2Extension syntax for maintenance.128Annex D(informative)Example.129D.1Example specification.129D.2Example SCL file contents.131Annex E(informative)XML schema definition of SCL variants.140Figure 1 Reference model for information flow in the configuration process.11Figure 2 SCL object model.13Figure 3 Configuration example.15Figure 4 UML diagram overview of SCL schema.21Figure 5 Elements of the signal identification as defined in IEC 61850-7-2.26Figure 6 Elements of the signal name using functional naming.27Figure 7 Elements of the signal name using product naming.27Figure 8 Names within different structures of the object model.28Figure 9 UML diagram of Header section.29Figure 10 UML diagram of Substation section.32Figure 11 UML diagram for equipment type inheritance and relations.36Figure 12-Substation section example.42Figure 13 IED structure and access points.45Figure 14 UML description of IED related schema part base.46Figure 15 UML description of IED related schema part for Control blocks.47Figure 16 UML description of IED related schema part LN definition.48Figure 17 UML diagram overview of the Communication section.70Figure 18 UML overview of DataTypeTemplate section.76Figure C.1 Coordinate example.126Figure D.1 T1-1 Substation configuration.129Figure D.2 T1-1 Communication configuration.130Figure D.3 T1-1 Transformer bay.131Table 1 The files composing the XML schema definition for SCL.20Table 2 Attributes of the Private element.23Table 3 Attributes of the Header element.29Table 4 Attributes of the History item(Hitem)element.30Table 5 Primary apparatus device type codes.38Table 6 Attributes of the Terminal element.39Table 7 Attributes of the SubEquipment element.40Table 8 Attributes of the LNode element.40Table 9 Attributes of the IED element.49Table 10 List of service capabilities and setting elements and attributes.50Table 11 Attributes of the Access point element.52Table 12 Attributes of the IED server element.53Table 13 Attributes of the Authentication element.54Table 14 Attributes of the LDevice element.54Table 15 Attributes of the LN0 element.5561850-6/CD1 IEC(E)4 57/798/CDTable 16 Attributes of the LN element.56Table 17 Attributes of the DOI element.57Table 18 Attributes of the DAI element.57Table 19 Attributes of the SDI element.58Table 20 Attributes of the DataSet element.59Table 21 Attributes of the FCDA element.59Table 22 Attributes of the FCCB element.59Table 23 Attributes of the report control block element.61Table 24 Attributes of the RptEnabled element.62Table 25 Attributes of the ClientLN element.62Table 26 Attributes of the log control block element.63Table 27 Attributes of the GSE control block element.64Table 28 Attributes of the sampled value control block element.65Table 29 Attributes of the Smv Options element.66Table 30 Attributes of the setting control block element.67Table 31 Attributes of the Input/ExtRef element.68Table 32 Attributes of the Association element.69Table 33 Attributes of the Subnetwork element.71Table 34 Attributes of the ConnectedAP element.71Table 35 Attributes of the GSE element.73Table 36 Attributes of the SMV element.74Table 37 PhysConn P-Type definitions.74Table 38 Template definition elements.78Table 39 Attributes of the LNodeType element.78Table 40 Attributes of the DO element.79Table 41 Attributes of the DOType element.79Table 42 Attributes of the SDO element.79Table 43 Data type mapping.80Table 44 Attribute value kind(Valkind)mea