温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_F_1674_
_18
Designation:F167418An American National StandardStandard Test Method forJoint Restraint Products for Use with PVC Pipe1This standard is issued under the fixed designation F1674;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope*1.1 This test method describes a procedure for qualifyingthe performance of joint restraint products for use on PVCpressure pipe systems by evaluating the effect of the jointrestraint product on the performance characteristics of PVCpipe during cyclic pressure tests and static pressure tests.ThePVC pipe property values referenced in this test method are forthe 12454 compound as described in Specification D1784 anda 4,000 HDB shall be obtained by categorizing the LTHS inaccordance with Table 1 in Test Method D2837.That includes,but is not limited to,pipe produced in accordance with thefollowing standards:Specifications D1785 and D2241,andAWWA C900.1.2 This test method determines the short-term performanceof a joint restraint product on PVC pipe,which involves thetesting of restrained joint test sections to the minimum burstpressure requirements of the pipe to determine quick burstperformance.1.3 This test method determines the long-term effect of ajoint restraint product on PVC pipe,which involves the testingof restrained joint test sections to the sustained pressurerequirements of the pipe for a period of 1000 h.1.4 This test method addresses restraint products that arerated at the full pressure capacity of the PVC pipe on whichthey are used.There are joint restraint devices available that arenot rated at the full pressure capacity of the pipe.While thoseproducts have proven acceptable and useful in the marketplace,this test method does not apply to those products.1.5 This test method determines the performance of a jointrestraint product on PVC pipe subjected to cyclic pressuresurges.The performance is compared to the baseline perfor-mance of pipe without joint restraint products established byHerbert W.Vinson.21.6 The values stated in inch-pound units are to be regardedas standard.The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.7 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:3D1784 Specification for Rigid Poly(Vinyl Chloride)(PVC)Compounds and Chlorinated Poly(Vinyl Chloride)(CPVC)CompoundsD1785 Specification for Poly(Vinyl Chloride)(PVC)PlasticPipe,Schedules 40,80,and 120D2241 Specification for Poly(Vinyl Chloride)(PVC)Pressure-Rated Pipe(SDR Series)D2837 Test Method for Obtaining Hydrostatic Design Basisfor Thermoplastic Pipe Materials or Pressure Design Basisfor Thermoplastic Pipe ProductsF412 Terminology Relating to Plastic Piping Systems2.2 AWWA Standards:AWWA C900 Polyvinyl Chloride(PVC)Pressure Pipe andFabricated Fittings,4 in.through 12 in.(100 mm through300 mm),for Water Distribution43.Terminology3.1 DefinitionsDefinitions are in accordance with Termi-nology F412 unless otherwise specified.1This test method is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.20 on Joining.Current edition approved Nov.1,2018.Published December 2018.Originallyapproved in 1996.Last previous edition approved in 2011 as F167411.DOI:10.1520/F1674-18.2Vinson,Herbert W.,Response of PVC Pipe to Large,Repetitive PressureSurges,International Conference on Underground Plastic Pipe,American Societyof Civil Engineers,New York,NY,1981,p.491.3For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.4Available from American Water Works Association(AWWA),6666 W.QuincyAve.,Denver,CO 80235,http:/www.awwa.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Princ