分享
ASTM_F_2466_-_10_2018.pdf
下载文档

ID:191427

大小:96.17KB

页数:5页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_F_2466_ _10_2018
Designation:F246610(Reapproved 2018)Standard Practice forDetermining Silicone Volatiles in Silicone Rubber forTransportation Applications1This standard is issued under the fixed designation F2466;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This practice covers a means to determine the percentsilicone-producing volatiles present in heat-cured siliconerubber and room temperature-cured silicones(RTV).1.2 Silicone-producing volatiles contribute to fouling ofoxygen sensor systems used in the control of vehicle emis-sions.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D3182 Practice for RubberMaterials,Equipment,and Pro-cedures for Mixing Standard Compounds and PreparingStandard Vulcanized SheetsE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3.Summary of Practice3.1 This practice consists of four(4)basic steps:(1)thesilicone is cured to its elastomeric form,(2)the volatiles areextracted from the cured material,(3)the extract is separatedand measured by gas chromatography(GC),and(4)the GCresults are quantified using a siloxane calibration.4.Significance and Use4.1 Use of this practice in conjunction with realistic maxi-mum volatility tolerance level can help minimize the risk ofoxygen sensor dysfunction from formed-in-place-sealants intransportation applications.This practice provides a method fordetermination of percentage volatiles in silicone elastomers.The volatile silicones from a commercial silicone are primarilycyclo dimethyl-siloxane.Other species present having GCretention times similar to those of the cyclics are assumed to besilicone as well.5.Apparatus5.1 Gas Chromatograph,fused silica capillary column sys-tem equipped with a flame ionization detector,split-typecapillary column injector,temperature programming capabilityand an appropriate data recording system.An alternative unitmay be an equivalent instrument equipped with a thermalconductivity detector,or as agreed upon between producer anduser.Specific column and operating conditions should beselected to optimize instrument response and chromatographicresolution,particularly separation of the internal standard fromextracted sample components.5.2 Column,suggested to be used is 30 to 60 m by 0.25 mmwith 0.25 to 1.5 m DB-1 or DB-5 fused silica capillarycolumn or equivalent.5.3 Operating conditions are:5.3.1 Column50 to 320C at 10C/min(a post-analysisperiod may be required to elute higher boiling componentsprior to subsequent analyses).5.3.2 Injector290C.5.3.3 Detector325C.5.3.4 Sample Size1 L.5.3.5 Injector Split Ratio2:1 to 50:1(adjusted as needed).5.3.6 Helium or Nitrogen,for the carrier gas.5.3.7 Carrier Gas Flow Velocity1 to 2 mL/min(adjustedas needed for column dimensions).5.4 Humidity Chamber,or controlled lab environment.5.5 Wrist-Action Mechanical Shaker.1This practice is under the jurisdiction ofASTM Committee F03 on Gaskets andis the direct responsibility of Subcommittee F03.50 on Analytical Test Methods.Current edition approved Aug.1,2018.Published September 2018.Originallyapproved in 2005.Last previous edition approved in 2010 as F2466 10.DOI:10.1520/F2466-10R18.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 5.6 Analytical Balance,with glass draft shield capable of0.0001 g accuracy.5.7 30-mL Vials,flint glass,with screw cap(polyethylenelined).5.8 Syringe,capable of accurately delivering 20 6 0.1 L(no plastic elements used due to solvents used).5.9 Solvents and standar

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开