_STP_1591
2015
STP 1591 A.Seth Greenwald Steven M.Kurtz Jack E.Lemons William M.MihalkoASTM INTERNATIONAL Selected Technical PapersModularity and Tapers in Total Joint Replacement DevicesSELECTED TECHNICAL PAPERSSTP1591Editors:A.Seth Greenwald,Steven M.Kurtz,Jack E.Lemons,William M.MihalkoModularity and Tapers in Total Joint Replacement Devices ASTM Stock#STP1591 DOI:10.1520/STP1591-EBASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.Printed in the U.S.A.Library of Congress Cataloging-in-Publication DataNames:Symposium on Modularity&Tapers in Total Joint Replacement Devices (2014:New Orleans,La.),author.|Greenwald,A.Seth,editor.|Kurtz,Steven M.,1968-,editor.|Lemons,Jack E.,editor.|Mihalko,William M.,editor.|ASTM International,sponsoring body.Title:Modularity and tapers in total joint replacement devices/editors,A.Seth Greenwald,Steven M.Kurtz,Jack E.Lemons,William M.Mihalko.Other titles:Journal of ASTM International.Selected technical papers;STP 1591.Description:West Conshohocken,PA:ASTM International,2015|Series:Selected technical papers;STP 1591|Includes bibliographical references and index.Identifiers:LCCN 2015037956|ISBN 9780803176270(alk.paper)|ISBN 9780803176287(alk.paper)Subjects:|MESH:Knee Prosthesis-Congresses.|Arthroplasty,Replacement,KneemethodsCongresses.Classification:LCC RD561|NLM WE 874|DDC 617.5/820592dc23 LC record available at?http:/lccn.loc.gov/2015037956Copyright 2015 ASTM INTERNATIONAL,West Conshohocken,PA.All rights reserved.This material may not be reproduced or copied,in whole or in part,in any printed,mechanical,electronic,film,or other distribution and storage media,without the written consent of the publisher.Photocopy RightsAuthorization to photocopy items for internal,personal,or educational classroom use,or the internal,personal,or educational classroom use of specific clients,is granted by ASTM International provided that the appropriate fee is paid to the Copyright Clearance Center,222 Rosewood Drive,Danvers,MA 01923,Tel:(978)646-2600;http:/ Society is not responsible,as a body,for the statements and opinions expressed in this publication.ASTM International does not endorse any products represented in this publication.Peer Review PolicyEach paper published in this volume was evaluated by two peer reviewers and at least one editor.The authors addressed all of the reviewers comments to the satisfaction of both the technical editor(s)and the ASTM International Committee on Publications.The quality of the papers in this publication reflects not only the obvious eforts of the authors and the technical editor(s),but also the work of the peer reviewers.In keeping with long-standing publication practices,ASTM International maintains the anonymity of the peer reviewers.The ASTM International Committee on Publications acknowledges with appreciation their dedication and contribution of time and efort on behalf of ASTM International.Citation of PapersWhen citing papers from this publication,the appropriate citation includes the paper authors,“paper title”,STP title,STP number,book editor(s),page range,Paper doi,ASTM International,West Conshohocken,PA,year listed in the footnote of the paper.A citation is provided on page one of each paper.Printed in Bay Shore,NY December,2015THIS COMPILATION OF Selected Technical Papers,STP1591,Modularity and Tapers in Total Joint Replacement Devices,contains peer-reviewed papers presented at a symposium held November 10,2014,in New Orleans,LA,USA.Te sympo-sium was sponsored by ASTM International Committee F04 on Medical and Surgi-cal Materials and Devices and Subcommittee F04.22 on Arthroplasty.Symposium Chairpersons and STP Editors:A.Seth GreenwaldOrthopaedic Research LaboratoriesCleveland,OHSteven M.KurtzExponent,Inc.Philadelphia,PAJack E.LemonsUniversity of Alabama at BirminghamBirmingham,ALWilliam M.MihalkoCampbell Clinic OrthopaedicsUniversity of TennesseeMemphis,TNForewordvOverview viiiThe Clinical PictureTrunnion Options in Primary Total Hip Arthroplasty in 2014 1Carlos J.Lavernia,Christopher P.Emerson,Jesus M.Villa,and Stephen D.CookOrthopaedic Surgeon Modularity Utilization and Surgical Technique Considerations in the Face of Implant Corrosion 10Marcus C.Ford,John W.Harkess,and William M.MihalkoPatient Outcomes Following Implantation of Modular Neck Hip Prostheses in Primary Total Hip Arthroplasty 17Robert Borden,Aidin Eslam Pour,Takayuki Murayama,and J.David BlahaCorrosion at the Head-Neck Taper Interface Afects the Prognosis of Hip Revision Surgery 26Emmanouil Liodakis,Alberto Carli,David Zukor,Olga Huk,and John AntoniouFretting Corrosion and Modularity:A Critical Review of the Literature and Three Registries 34John M.CucklerRetrieval Taper Connection Damage AssessmentsIs Taper Fretting Corrosion a Threat to the Clinical Performance of Large-Diameter Hips with Highly Crosslinked Polyethylene Bearings?45Steven M.Kurtz,Daniel W.MacDonald,Jeremy L.Gilbert,Michael A.Mont,Gregg Klein,Antonia Chen,Matthew Kraay,Brian Hamlin,and