分享
ASTM_F_2561_-_11.pdf
下载文档

ID:191155

大小:77.05KB

页数:4页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_F_2561_ _11
Designation:F256111Standard Practice forRehabilitation of a Sewer Service Lateral and Its Connectionto the Main Using a One Piece Main and Lateral Cured-in-Place Liner1,2This standard is issued under the fixed designation F2561;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This practice covers requirements and test methods forthe reconstruction of a sewer service lateral pipe having aninner diameter of 3 to 12 in.and its connection to the main pipehaving an inner diameter of 6 to 24 in.without excavation.Thelateral pipe is accessed remotely from the main pipe and froma lateral cleanout.This will be accomplished by the installationof a resin impregnated one-piece main and lateral curedin-place lining(MLCIPL)by means of air or water inflationand inversion.The MLCIPL is pressed against the host pipe bypressurizing a bladder and is held in place until the thermosetresins have cured.When cured,the MLCIPL shall be acontinuous,one piece,tight fitting,corrosion resistant liningextending over a predetermined length of the lateral pipe andthe adjacent section of the main pipe providing a verifiablenon-leaking structural connection and seal.1.2 The values stated in inch-pound units are to be regardedas standard.The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 There is no similar or equivalent ISO Standard.1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.Particular attentionis drawn to those safety regulations and requirements involvingentering into and working in confined spaces.2.Referenced Documents2.1 ASTM Standards:3D618 Practice for Conditioning Plastics for TestingD790 Test Methods for Flexural Properties of Unreinforcedand Reinforced Plastics and Electrical Insulating Materi-alsD1600 Terminology forAbbreviated Terms Relating to Plas-ticsD3681 Test Method for Chemical Resistance of“Fiberglass”(GlassFiberReinforced Thermosetting-Resin)Pipe in aDeflected ConditionD5813 Specification for Cured-In-Place ThermosettingResin Sewer Piping SystemsF412 Terminology Relating to Plastic Piping SystemsF1216 Practice for Rehabilitation of Existing Pipelines andConduits by the Inversion and Curing of a Resin-Impregnated Tube2.2 NASSCO Guidelines:4Recommended Specifications for Sewer Collection SystemRehabilitation3.Terminology3.1 DefinitionsUnless otherwise indicated,definitions arein accordance with Terminology F412,and abbreviations are inaccordance with Terminology D1600.3.2 Definitions of Terms Specific to This Standard:3.2.1 access pointan existing manhole at either the up-stream or downstream end of a sewer main or a cleanoutlocated on the lateral pipe.3.2.2 bladdera transparent flexible plastic hose that whenpressurized,causes the main sheet to be pressed against themain pipe walls and the lateral tube to invert up into the sewerservice lateral.The bladder joined with the textile liningcreates a liner/bladder assembly.1This practice is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.67 onTrenchless Plastic Pipeline Technology.Current edition approved Dec.1,2011.Published December 2011.Originallyapproved in 2006.Last previous edition approved in D256106.DOI:10.1520/F2561-11.2The rehabilitation of a sewer service lateral and its connection to the main usinga one-piece main and lateral cured-in-place liner is covered by patents(LMKEnterprises,Inc.1779 Chessie Lane,Ottawa,IL 61350).Interested parties areinvited to submit information regarding the identification of acceptable alternativesto this patented item to the Committee on Standards,ASTM Headquarters,100 BarrHarbor Drive,West Conshohocken,PA 19428-2959.Your comments will receivecareful consideration at a meeting of the responsible technical committee which mayattend.3For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.4NASSCO,Inc.11521 Cronridge Drive,Suite J,Owings Mills,MD 21117.www.nassco.orgCopyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 3.2.3 inversionthe process of turning a resin-impregnatedtube inside out by the use of air or water pressure.3.2.4 launchercombination of a rigid elongated tube andlay-flat hose apparatus where the main bladder is attached andthe main sheet is

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开