温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_F_710_
_19
Designation:F71019Standard Practice forPreparing Concrete Floors to Receive Resilient Flooring1This standard is issued under the fixed designation F710;the number immediately following the designation indicates the year of originaladoption or,in the case of revision,the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This practice covers the determination of the acceptabil-ity of a concrete floor for the installation of resilient flooring.1.2 This practice includes suggestions for the constructionof a concrete floor to ensure its acceptability for installation ofresilient flooring.1.3 This practice does not cover the adequacy of theconcrete floor to perform its structural requirements.1.4 This practice covers the necessary preparation of con-crete floors prior to the installation of resilient flooring.1.5 This practice does not supersede in any manner theresilient flooring or adhesive manufacturers written instruc-tions.Consult the individual manufacturer for specific recom-mendations.1.6 Although carpet tiles,carpet,wood flooring,coatings,films,and paints ae not specifically intended to be included inthe category of resilient floor coverings,the procedures in-cluded in this practice may be useful for preparing concretefloors to receive such finishes.1.7 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.See 4.1.1,7.1.1,and 7.1.2 for specific warning statements.1.8 The values stated in inch-pound units are to be regardedas standard.The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.9 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2C109/C109M Test Method for Compressive Strength ofHydraulic Cement Mortars(Using 2-in.or 50-mm CubeSpecimens)C472 Test Methods for Physical Testing of Gypsum,Gyp-sum Plasters and Gypsum ConcreteD4259 Practice for Preparation of Concrete by AbrasionPrior to Coating ApplicationD4263 Test Method for Indicating Moisture in Concrete bythe Plastic Sheet MethodD4397 SpecificationforPolyethyleneSheetingforConstruction,Industrial,and Agricultural ApplicationsE1155 Test Method for Determining FFFloor Flatness andFLFloor Levelness NumbersE1486 Test Method for Determining Floor Tolerances UsingWaviness,Wheel Path and Levelness CriteriaE1745 Specification for Plastic Water Vapor Retarders Usedin Contact with Soil or Granular Fill under Concrete SlabsF141 Terminology Relating to Resilient Floor CoveringsF710 Practice for Preparing Concrete Floors to ReceiveResilient FlooringF1869 Test Method for Measuring Moisture Vapor EmissionRate of Concrete Subfloor Using Anhydrous CalciumChlorideF2170 Test Method for Determining Relative Humidity inConcrete Floor Slabs Using in situ ProbesNOTE1Specifications and test methods for cements and other relatedmaterials are found in ASTM Volume 04.01.Specifications and testmethods for concretes and related materials are found in ASTM Volume04.02.2.2 ACI Guides:3302.1R-06 Guide for Concrete Floor and Slab Construction302.2R-06 Guide for Concrete Slabs that Receive Moisture-Sensitive Flooring Materials117R Standard Tolerances for Concrete Construction andMaterials1This practice is under the jurisdiction of ASTM Committee F06 on ResilientFloor Coverings and is the direct responsibility of Subcommittee F06.40 onPractices.Current edition approved Feb.1,2019.Published March 2019.Originallyapproved in 1981.Last previous edition approved in 2017 as F710 17.DOI:10.1520/F0710-19.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from American Concrete Institute(ACI),38800 Country Club Dr.,Farmington Hills,MI 48331-3439,http:/www.concrete.org.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 2.3 Resilient Floor Covering Institute(RFCI):4Recommended Work