Designation:F3010−18StandardPracticeforTwo-ComponentResinBasedMembrane-FormingMoistureMitigationSystemsforUseUnderResilientFloorCoverings1ThisstandardisissuedunderthefixeddesignationF3010;thenumberimmediatelyfollowingthedesignationindicatestheyearoforiginaladoptionor,inthecaseofrevision,theyearoflastrevision.Anumberinparenthesesindicatestheyearoflastreapproval.Asuperscriptepsilon(´)indicatesaneditorialchangesincethelastrevisionorreapproval.1.Scope1.1Thispracticecoverstheproperties,application,andperformanceofatwo-componentresinbasedmembrane-formingmoisturemitigationsystemtohighmoistureconcretesubstratespriortotheinstallationofresilientflooring.1.2Thispracticeincludesrecommendationsfortheprepa-rationoftheconcretesurfacetoreceiveatwo-componentresinbasedmembrane-formingmoisturemitigationsystem.1.3Thispracticedoesnotsupersedewritteninstructionsofthetwo-componentresinbasedmembrane-formingmoisturemitigationsystemmanufacturer,theresilientflooringmanufacturer,underlaymentmanufacturer,theadhesivemanufacturer,orothercomponentsofthefinishflooringsystem,orcombinationsthereof.Usersofthispracticeshallreviewmanufacturer’stechnicaldatasheetsandinstallationinstructionsforcompatibilityofsystemcomponents.1.4Thefollowingmembrane-formingornonmembrane-formingmoisturemitigationsystemsarenotincludedinthescopeofthispractice:1.4.1Moisturemitigationsystemsthatchemicallyreactwithanyconstituentoftheconcretetoformagelorcrystallinesubstancewithintheconcrete.1.4.2Penetrating,water-orsolvent-basedcompoundsthatdonotformacontinuousmembraneontheconcretesurface.1.4.3Water-basedmembrane-formingmoisturemitigationsystemsarenotincludedinthescopeofthisdocument.1.5Thevaluesstatedininch-poundunitsaretoberegardedasstandard.ThevaluesgiveninparenthesesaremathematicalconversionstoSIunitsthatareprovidedforinformationonlyandarenotconsideredstandard.1.6Thisstandarddoesnotpurporttoaddressallofthesafetyconcerns,ifany,associatedwithitsuse.Itistheresponsibilityoftheuserofthisstandardtoestablishappro-priatesafety,h...