分享
ASTM_F_2307_-_03.pdf
下载文档

ID:190581

大小:54.79KB

页数:5页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_F_2307_ _03
Designation:F 2307 03An American National StandardStandard Specification forSeries 10 Poly(Vinyl Chloride)(PVC)Closed Profile GravityPipe and Fittings Based on Controlled Inside Diameter1This standard is issued under the fixed designation F 2307;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon(e)indicates an editorial change since the last revision or reapproval.1.Scope1.1 This specification covers requirements for 10 psi pipestiffness poly(vinyl chloride)(PVC)closed profile sewer pipeand fittings with integral bell and elastomeric seal joints orplain end pipe with couplings in sizes(18 to 60 in.)based ona controlled inside diameter.1.2 The values stated in inch-pound units are to be regardedas the standard.The values given in parentheses are forinformation only.1.3 The following safety hazard caveat pertains only to thetest methods portion,Section 8,of this specification:Thisstandard does not purport to address all of the safety concerns,if any,associated with its use.It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.NOTE1Pipe and fittings produced to this specification should beinstalled in accordance with Practice D 2321.2.Referenced Documents2.1 ASTM Standards:D 618 Practice for Conditioning Plastics for Testing2D 1600 Terminology for Abbreviated Terms Relating toPlastics2D 1784 Specification for Rigid Poly(Vinyl Chloride)(PVC)Compounds and Chlorinated Poly(Vinyl Chloride)(CPVC)Compounds2D 2122 Test Method for Determining Dimensions of Ther-moplastic Pipe and Fittings3D 2152 Test Method for Adequacy of Fusion of ExtrudedPoly(Vinyl Chloride)(PVC)Pipe and Molded Fittings byAcetone Immersion3D 2321 Practice for Underground Installation of FlexibleThermoplastic Pipe for Sewers and Other Gravity-FlowApplications3D 2412 Test Method for Determination of External LoadingCharacteristics of Plastic Pipe by Parallel-Plate Loading3D 2444 Test Method for Impact Resistance of Thermoplas-tic Pipe and Fittings by Means of a Tup(Falling Weight)3D 2855 Practice for Making Solvent-Cemented Joints withPoly(Vinyl Chloride)(PVC)Pipe and Fittings3D 3212 Specification for Joints for Drain and Sewer PlasticPipes Using Flexible Elastomeric Seals3F 402 Practice for Safe Handling of Solvent Cements,Primers,and Cleaners Used for Joining Thermoplastic Pipeand Fittings3F 412 Terminology Relating to Plastic Piping Systems3F 477 Specification for Elastomeric Seals(Gaskets)forJoining Plastic Pipe3F 679 Specification for Poly(Vinyl Chloride)(PVC)Large-Diameter Plastic Gravity Sewer Pipe and Fittings32.2Federal Standard:Fed.Std.No.123 Marking for Shipment(Civil Agencies)42.3Military Standard:MIL-STD-129 Marking for Shipment and Storage43.Terminology3.1 DefinitionsDefinitions are in accordance with Termi-nology F 412,and abbreviations are in accordance with Ter-minology D 1600,unless otherwise specified.The abbreviationfor poly(vinyl chloride)is PVC.3.2 Definitions of Terms Specific to This Standard:3.2.1closed profile(CP)gravity sewer pipe,na pipeproduct consisting of an essentially smooth waterway bracedcircumferentially or spirally with projections or ribs that arejoined by an essentially smooth outer wall(see Fig.1).4.Significance and Use4.1 The requirements of this specification are intended toprovide pipe and fittings suitable for nonpressure drainage ofsewage and surface water.NOTE2Industrial waste disposal lines should be installed only withthe specific approval of the governing code authority since chemicals not1This specification is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.Current edition approved August 10,2003.Published September 2003.2Annual Book of ASTM Standards,Vol 08.01.3Annual Book of ASTM Standards,Vol 08.04.4Available from Standardization Documents Order Desk,Bldg.4 Section D,700Robbins Ave.,Philadelphia,PA 191115094,Attn:NPODS.1Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959,United Smonly found in drains and sewers and temperatures in excess of140F may be encountered.5.Material5.1 Basic Materials The pipe and fittings shall be made ofPVC plastic having a minimum cell classification of 12454C or12364C as defined in Specification D 1784.HomopolymerPVC compounds must meet or exceed the requirements of theabove listed minimum cell classification number.5.2 Rework Material Clean rework material generatedfrom the manufacturers own pipe or fittings production maybe used by the same manufacturer provided pipe or fittingsproduced meet all the requirements of this specification.5.3 GasketsElastomeric gaskets shall comply with therequirements described in Specification F 477.5.4 LubricantThe lub

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开