温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_F_967_
_03_2011
Designation:F96703(Reapproved 2011)Standard Practice forSecurity Engineering Symbols1This standard is issued under the fixed designation F967;the number immediately following the designation indicates the year of originaladoption or,in the case of revision,the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This practice utilizes symbols to depict security systemsand equipment requirements for architectural or engineeringdrawings that are produced either manually or by computeraided design(CAD).The symbols depicted include somesymbols that have already been somewhat universally acceptedor that have already been adopted by a standards-writing body,such as by the National Fire Protection Association.1.2 It is not proposed that all of the symbols need to beutilized since the level of detail required for drawings is likelyto vary.Generic symbols of a class of security device may besufficient in some instances.Moreover,the need to provide ameasure of security in the actual drawing may also suggest aneed to utilize a generic symbol rather than to depict the exactdevice being installed.1.3 In the event that a greater level of detail is required,it ispossible to combine many of the symbols to create newsymbols that achieve the desired level.While some combina-tions of symbols are shown,it would be impractical to attemptto depict every conceivable combination of symbols.It is alsothe intent of this practice that the symbols be capable of beingcontinuously expanded and modified as the industry state of theart changes or as emphasis varies.For example,little attentionis given to document security in the security symbols sincesuch requirements are not generally fully met during construc-tion periods but are rather developed and provided for subse-quently.Since much of this equipment is not installed but is“placed,”such as furniture,there is only one symbol proposed(for example,for document shredders).1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Keywords2.1 computer aided design;security engineering;symbols1.ANNOTATIONExisting EquipmentPoint and Zone IndicatorConnection Between Devices(for example,button and lock)Detail and Reference DrawingDoor Number(if more than one door in room,use sub-letter)Room or Space NumberDevice Number(reference device schedule)Device ReferenceA=Drawing SheetB=DetailC=Device Zone Number2.ACCESS CONTROLGeneric Card Reader(reference door schedule orspecifications for type):P=pedestal mountCard Reader with Touch Pad1This practice is under the jurisdiction of ASTM Committee F12 on SecuritySystems and Equipmentand is the direct responsibility of Subcommittee F12.10 onSystems Products and Services.Current edition approved March 1,2011.Published June 2011.Originallyapproved in 1986.Last previous edition approved in 2003 as F967 03.DOI:10.1520/F0967-03R11.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 Token-Type Access ControlCCTV and Card ReaderCCTV and IntercomSplit Lens CCTV with ID Card ReceptacleApartment Type CCTV with House Phone andTouch Pad(insert“K”“”,as appropriate for key switch)Biometric Access Control Device(reference doorschedule or specifications for type)Touch Pad Lock or Device,Mechanical orElectronic(reference door schedule for type)Turnstile(reference door schedule for type andfunction)Post and Rail(rope)Generic Screening DeviceX:M=Metal DetectorE=Explosive DetectorX=X-rayT=Tag Detector(EAS)Sally PortIndicating Interlocking DoorsIndicating Space is a“Man-Trap”Card Access ReaderB=BarcodeW=WiegandP=ProximityM=Mag StripeF=Elevator Floor CallH=Elevator Hall CallT=TokenS=Smart CardBiometrics Access Control DeviceH=Hand GeometryF=Finger PrintV=VoiceR=Eye RetinaI=Eye IrisKeypad DeviceCard Reader with KeypadCard Reader with Time and Attendance3.ANNUNCIATION:CONSOLE/PANELStrip(Tallyroll)PrinterPrinterTime Clock with Card ReaderCentral Processing UnitCRT(cathode ray tube/display)Static Map Display(for dynamic map display,use CRT symbol)KeyboardJeweled Signal LightPanel Light Indicator(R=Red,A=Amber,W=White,V=Violet,G=Green,Y=Yellow,B=Blue,O=Orange)Multiplex PanelPanel Sound IndicatorPanel Sound and Light IndicatorF967 03(2011)2 ResetPush-Button,Momentary/Make(circuitclosing)Time Delay ModuleControl Device Module,Door ReleaseEnd-of-Line Device ModuleResistance(Ohms)(indicate value;that is,10 000)ThousandsDry Contacts,SetContacts with CurrentPower SwitchField PanelT:C=Card ReaderA=AlarmControl PanelT:B=BurglarF=FireP=PerimeterD=DoorCentral Processing UnitKeyboardPrinterPower SupplyT:L=LockC=CameraP=PanelI=Intercom4.ANNUNCIATION:DEVICESAnnunciation Device,GenericBu