分享
ASTM_F_2608_-_15.pdf
下载文档

ID:190311

大小:256.62KB

页数:9页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_F_2608_ _15
Designation:F260815An American National StandardStandard Test Method forDetermining the Change in Room Air Particulate Counts asa Result of the Vacuum Cleaning Process1This standard is issued under the fixed designation F2608;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method provides a laboratory test for themeasurement of particulate generated as a direct result of thevacuuming process.1.2 This test method is applicable to all residential/commercial uprights,canisters,stickvacs,central vacuumsystems,and combination cleaners.1.3 This test method applies to test dust removal from floorcoverings not the removal of surface litter and debris.1.4 The values stated in SI units are to be regarded asstandard.The values given in parentheses are for informationonly.1.5 This test method may involve hazardous materials,operations,and equipment.This standard does not purport toaddress all of the safety concerns,if any,associated with itsuse.It is the responsibility of the user of this standard toestablish appropriate safety and health practices and deter-mine the applicability of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2F555 Test Method for Motor Life Evaluation of an UprightVacuum CleanerF608 Test Method for Evaluation of Carpet Embedded DirtRemovalEffectivenessofHousehold/CommercialVacuum CleanersF655 Specification for Test Carpets and Pads for VacuumCleaner TestingF884 Test Method for Motor Life Evaluation of a Built-In(Central Vacuum)Vacuum CleanerF922 Test Method for Motor Life Evaluation of an ElectricMotorized NozzleF1038 Test Method for Motor Life Evaluation of a Canister,Hand-held,Stick,and Utility Type Vacuum Cleaner With-out a Driven AgitatorF1334 Test Method for Determining A-Weighted SoundPower Level of Vacuum CleanersF1409 Test Method for Straight Line Movement of VacuumCleaners While Cleaning Carpets2.2 AHAM Standard:ANSI/AHAM AC-1-2006 Test Method for Performance ofPortable Household Electric Room Air Cleaners32.3 Other References:IEC 60312 Vacuum Cleaners for Household UseMethodsfor Measuring the PerformanceStandard Laboratory Practice for Quantifying RespirableParticulateEmissionsGeneratedbyResidential/Commercial Vacuums and Central Vacuum Systems,Car-pet and Rug Institute,12/4/023.Terminology3.1 Definitions:3.1.1 model,ndesignation of a group of vacuum cleanershaving identical mechanical and electrical construction withonly cosmetic or nonfunctional differences.3.1.2 population,ntotal of all units of a particular modelvacuum cleaner being tested.3.1.3 repeatability limit,nvalue below which the absolutedifference between two individual test results obtained underthe repeatability condition may be expected to occur with aprobability of approximately 0.95(95%).3.1.4 test run,ndefinitive procedure that produces a sin-gular measured result.3.1.5 unit,nsingle vacuum cleaner of the model beingtested.4.Significance and Use4.1 In this test method,the amount of particulate generatedinto the air by operating a vacuum cleaner over a specific floorcovering that is contaminated with dust will be determined.1This test method is under the jurisdiction ofASTM Committee F11 on VacuumCleaners and is the direct responsibility of Subcommittee F11.23 on Filtration.Current edition approved Nov.1,2015.Published November 2015.Originallyapproved in 2007.Last previous edition approved in 2014 as F260807(2014).DOI:10.1520/F2608-15.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from the Association of Home Appliance Manufacturers,19th St.NW,Suite 402,Washington,DC 20036.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 Particles from the motor,floor covering,and the test dust willall be measured.The amount of dust generated in the labora-tory practice will differ from that in residential/commercialinstallations because of variations in floor coverings,soil andother solid particulate compositions,the vacuuming processused by individual operators,the air exchange rate of heating,ventilation,and air conditioning(HVAC)systems,and otherfactors.4.2 To provide a uniform basis for measuring the perfor-mance in 4.1,a standardized test chamber,equipment,floorcovering material,and dust particulate are used in this testmethod.4.3 Due to the large range of generated particle countsobserved among products in the vacuum cleaner industry at thepresent time,the test results of the maximum particle countsgenerated under this test method are expressed in Log10equivalents for evaluation and com

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开