分享
ASTM_F_1790_-_F_1790M_-_15.pdf
下载文档

ID:190148

大小:242.84KB

页数:10页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_F_1790_ _F_1790M_ _15
Designation:F1790/F1790M15Standard Test Method forMeasuring Cut Resistance of Materials Used in ProtectiveClothing with CPP Test Equipment1This standard is issued under the fixed designation F1790/F1790M;the number immediately following the designation indicates the yearof original adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.A superscript epsilon()indicates an editorial change since the last revision or reapproval.INTRODUCTIONCut resistance is an important property for protective clothing and equipment,and several standardtesting devices have been adopted across different industries to measure this property.A commonpractice in cut resistance testing is to subject a material specimen to a transversely moving blade underan applied load and measure the distance of blade travel required to cut through the specimen.Thistest method calculates the load required to cut through different specimens at 25.4 mm 1 in.bladetravel.This calculated load,defined as the calculated cutting load,can be used to compare the cutresistance of materials.The original F1790-97 test method defined a commercially-available apparatus known as the CutProtection Performance Tester(CPP).In an attempt to harmonize F1790/F1790M with ISO 13997(another international testing standard for measuring cut resistance)and improve the test method,thescope of the test method was changed in F1790-05 to allow the use of other cut testing equipment,specifically the Tomodynamometer(TDM-100)and a modification to the CPParm called the ModifiedCPP(mCPP).The revision addressed issues related to measurement of high frictional coefficientmaterials like elastomers,specimen mounting,calculated cutting load determination,and otherprocedures to harmonize with ISO 13997:1999.After further round-robin evaluation by thesubcommittee,it was demonstrated that the revisions to the test method result in a bias between theoriginal F1790-97 test method and the revised F1790-05 test method when using the CPP.F1790-05was not widely adopted in NorthAmerica because of this bias and large amount of data and experienceaccumulated with F1790-97.F1790-97 continues to be the test method predominately practiced whenusing the CPP device.To reduce confusion for end-users of F1790/F1790M and to allow fordifferences between testing devices,the subcommittee has decided to limit the scope of F1790/F1790M to include only the CPP device and created a separate test method for use of the TDM-100(Test Method F2992/F2992M).1.Scope1.1 This test method covers the measurement of the cutresistance of a material when mounted on a mandrel andsubjected to a cutting edge under a specified load using the CutProtection Performance(CPP)Tester.1.1.1 This procedure is not valid for high-porosity materialswhich allow cutting edge contact with the mounting surfaceprior to cutting.1.1.2 Test apparatus may have limitations in testing materi-als with a thickness greater than 3 mm or having a highfrictional coefficient such as elastomers.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard.The values stated ineach system may not be exact equivalents;therefore,eachsystem shall be used independently of the other.Combiningvalues from the two systems may result in non-conformancewith the standard.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1This test method is under the jurisdiction ofASTM Committee F23 on PersonalProtective Clothing and Equipment and is the direct responsibility of SubcommitteeF23.20 on Physical.Current edition approved Nov.1,2015.Published January 2016.Originallyapproved in 1997.Last previous edition approved in 2014 as F1790/F1790M 14.DOI:10.1520/F1790_F1790M-15.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 2.Referenced Documents2.1 ASTM Standards:2D123 Terminology Relating to TextilesD1000 Test Methods for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applica-tionsD1776/D1776M Practice for Conditioning and Testing Tex-tilesF1494 Terminology Relating to Protective ClothingF2992/F2992M Test Method for Measuring Cut Resistanceof Materials Used in Protective Clothing with Tomodyna-mometer(TDM-100)Test Equipment2.2 ISO Standards:3ISO 13997 Protective ClothingMechanical PropertiesDetermination of Resistance to Cutting by Sharp Objects3.Terminology3.1 Definitions:3.1.1 cut resistance,nin blade cut testing,the propertythat hinders cut through when a material or a combination ofmaterials is exposed to a sharp-edged device.3.1.2 cut through,nin blade cut resistance tests,thepenetration of the cutting edge entirely through material,asindicated by electrical c

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开