分享
ASTM_F_1735_-_09_2015.pdf
下载文档

ID:189855

大小:195.50KB

页数:5页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_F_1735_ _09_2015
Designation:F173509(Reapproved 2015)Standard Specification forPoly(Vinyl Chloride)(PVC)Profile Strip for PVC Liners forRehabilitation of Existing Man-Entry Sewers and Conduits1This standard is issued under the fixed designation F1735;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope*1.1 This specification covers requirements and test methodsfor materials,dimensions,workmanship,extrusion quality,anda form of marking for extruded poly(vinyl chloride)(PVC)profile strips used for field fabrication of PVC liners forexisting man-entry(36 to 144 in.(900 to 3650 mm)in verticaldimension)sewer and conduit rehabilitation.1.2 Profile strip produced to this specification is for use infield fabrication of PVC liners in non-pressure pipe and conduitrehabilitation where the liner is installed into the existing seweror conduit and the annular space between the liner and theexisting sewer or conduit is grouted with cementitious grout.NOTE1The practice for the installation of PVC liner covered by thisspecification is Practice F1698.1.3 This specification includes extruded profile strips madeonly from materials specified in 6.1.1.4 The values stated in inch-pound units are to be regardedas standard.The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD790 Test Methods for Flexural Properties of Unreinforcedand Reinforced Plastics and Electrical Insulating Materi-alsD883 Terminology Relating to PlasticsD1600 Terminology forAbbreviated Terms Relating to Plas-ticsD1784 Specification for Rigid Poly(Vinyl Chloride)(PVC)Compounds and Chlorinated Poly(Vinyl Chloride)(CPVC)CompoundsD2122 Test Method for Determining Dimensions of Ther-moplastic Pipe and FittingsD2152 Test Method for Adequacy of Fusion of ExtrudedPoly(Vinyl Chloride)(PVC)Pipe and Molded Fittings byAcetone ImmersionD2240 Test Method for Rubber PropertyDurometer Hard-nessF412 Terminology Relating to Plastic Piping SystemsF1698 Practice for Installation of Poly(Vinyl Chlo-ride)(PVC)Profile Strip Liner and Cementitious Grout forRehabilitation of Existing Man-Entry Sewers and Con-duits2.2 Federal Standard:Federal Standard No.123 Marking For Shipment(CivilAgencies)32.3 Military Standard:MIL-STD-129 Marking for Shipment and Storage33.Terminology3.1 GeneralDefinitions are in accordance with Terminol-ogy D883 and Terminology F412.Abbreviations are in accor-dance with Terminology D1600,unless otherwise indicated.3.2 Definitions of Terms Specific to This Standard:3.2.1 See Fig.1 to clarify terminology.3.2.2 coextruded elastomer seal,na elastomer coextrudedin the joiner strip to provide compression sealing of themechanical joint made when the joiner strip locks adjacentedges of former strip.3.2.3 extruded PVC joiner strip,na companion product tothe profile former strip of such configuration as to provide thelocking mechanism at the edges of the former strips.3.2.4 extruded PVC profile former strip,na product,available in various sizes,consisting of a smooth inner surface1This specification is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.67 onTrenchless Plastic Pipeline Technology.Current edition approved March 1,2015.Published April 2015.Originallyapproved in 1996.Last previous edition approved in 2009 as F1735-09.DOI:10.1520/F1735-09R15.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from DLA Document Services,Building 4/D,700 Robbins Ave.,Philadelphia,PA 19111-5094,http:/quicksearch.dla.mil.*A Summary of Changes section appears at the end of this standardCopyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 FIG.1 An Example of A Profile PVC StripF1735 09(2015)2 and a ribbed outer surface(profile)with edge configurations toallow mechanical locking of adjacent strips.3.2.5 production run,na continuous extrusion of a givenprofile type.3.2.6 PVC liner,na product field fabricated from extrudedPVC profile strip into a shape which substantially conforms tothe shape of the inner surface of the existing pipe or conduitover some portion or all of its inner circumf

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开