分享
ASTM_F_2143_-_04_2010.pdf
下载文档

ID:189807

大小:463.19KB

页数:12页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_F_2143_ _04_2010
Designation:F214304(Reapproved 2010)An American National StandardStandard Test Method forPerformance of Refrigerated Buffet and Preparation Tables1This standard is issued under the fixed designation F2143;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method covers evaluation of the energy con-sumption and refrigeration performance of refrigerated buffetand preparation tables.The food service operator can use thisevaluation to select a refrigerated buffet and preparation tableand understand its energy performance.1.2 This test method is applicable to electric self-containedrefrigerators used for holding and displaying refrigerated foodin an open area.1.3 The refrigerated buffet and preparation table can beevaluated with respect to the following(where applicable):1.3.1 Maximum energy input rate,or maximum currentdraw(10.1),1.3.2 Thermostat calibration(10.4),1.3.3 Lid up energy rate and temperature performance(10.5),and1.3.4 Lid down energy rate(10.6).1.4 The values stated in inch-pound units are to be regardedas standard.The SI units given in parentheses are for informa-tion only.1.5 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 NSF Standard:2NSF,Listing-Food Equipment and Related,Components andMaterialANSI/NSF 7 Commercial Refrigerators and Freezers2.2 ASHRAE Guideline:3ASHRAE Guideline 2-1986(RA90)Engineering Analysisof Experimental Data2.3 ANSI/ASHRAE Standards:4ANSI/ASHRAE 117 Method of Testing Closed Refrigera-torsANSI/ASHRAE 72 Method of Testing Open Refrigeratorsfor Food Stores2.4 Food and Drug Administration,U.S.Public HealthService Regulation:5Food Code,19993.Terminology3.1 Definitions:3.1.1 box car average,na locations thermocouple tem-perature averaged over a 1-h period.During the 4-h holdingenergy rate test,thermocouple temperatures are recorded at5-min intervals.The first box car average is the average ofreadings 1 through 12.The second box car average is theaverage of temperature readings 2 through 13,and so on.63.1.2 energy input rate,npeak rate at which a refrigeratedbuffet and preparation table consumes energy(kW).3.1.3 lid down energy rate,naverage rate of buffet/preparation table energy consumption(kW)with the upper lidclosed over the refrigerated rail containing pans of syntheticfood.3.1.4 lid up energy rate,naverage rate of buffet/preparation table energy consumption(kW)while it maintainsthe temperature of pans of synthetic food in the refrigerated railwith the upper lid open and the cabinet doors closed.3.1.5 production capacity,nmaximum volumetric storagecapacity(ft3(m3)at which the refrigerated buffet and prepa-ration tables open display area can hold using a specifiedcontainer filled to12in.of the container rim.1This test method is under the jurisdiction of ASTM Committee F26 on FoodService Equipment and is the direct responsibility of Subcommittee F26.06 onProductivity and Energy Protocol.Current edition approved March 1,2010.Published May 2010.Originallyapproved in 2001.Last previous edition approved in 2004 as F2143 04.DOI:10.1520/F2143-04R10.2Available from NSF International,P.O.Box 130140,789 N.Dixboro Rd.,AnnArbor,MI 48113-0140,http:/www.nsf.org.3Available from American Society of Heating,Refrigerating,and Air-Conditioning Engineers,Inc.(ASHRAE),1791 Tullie Circle,NE,Atlanta,GA30329,http:/www.ashrae.org.4Available from American National Standards Institute(ANSI),25 W.43rd St.,4th Floor,New York,NY 10036,http:/www.ansi.org.5Available from National Technical Information Service(NTIS),5285 PortRoyal Rd.,Springfield,VA 22161,http:/www.ntis.gov.6Based on ANSI/NSF 7,available from NSF International,P.O.Box 130140,Ann Arbor,MI 48113-0140.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 3.1.6 refrigerated buffet and preparation table,nbuffet/preparation table herein,equipment designed with a refriger-ated open top or open condiment rail.3.1.7 refrigerated buffet table or unit,nequipment de-signed with mechanical refrigeration that is intended to receiverefrigerated food and maintain food product temperatures andis intended for customer service such as a salad bar.Aunit mayor may not be equipped with a lower refrigerated compart-ment.63.1.8 refrigerated food preparation unit,nequipment de-signed with a refrigerated open top or open condiment rail suchas refrigerated sandwich units,pizza preparation tables,andsimilar equipment.The unit may or may not be equipped witha lower refrigerated compartment.63.1.9 self-co

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开