TM_F_1989_
_05_2013
Designation:F198905(Reapproved 2013)Standard Specification forCooking Fire Suppression Blankets1This standard is issued under the fixed designation F1989;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This specification covers requirements for cooking firesuppression blankets to extinguish accidental cooking fires.1.2 This specification does not apply to cooking fire sup-pression blankets that:are made from asbestos;have sides ofdiffering appearance,finish or color;have a performance thatdiffers according to which side is used;or,are of metallicconstruction or component.1.3 The values stated in SI units are to be regarded as thestandard.1.4 The following safety hazards caveat pertains only to thetest methods portion of this specification,Section 4:Thisstandard does not purport to address all of the safety concerns,if any,associated with its use.It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2.Terminology2.1 DefinitionsFor the purpose of this specification,thefollowing definition applies:2.1.1 fire blanket,nflexible sheet(s)of material intendedto be used to extinguish small fires by smothering.3.Physical Properties3.1 Size and ShapeCooking fire suppression blankets shallbe rectangular or square,with no edge less than 0.91 6 0.05 m(36 6 2 in.).3.2 MassCooking fire suppression blankets shall have amass not exceeding 2 kg(4.4 lb).3.3 Hand Holding Devices:3.3.1 Hand holding devices,if provided,shall consist ofsewn in straps on both sides of the blanket to facilitate quickrelease.The strap length shall not be less than 100 mm(3.9 in.)or more than 200 mm(7.8 in.)in length,and easily grasped andreleased when applying the blanket over a cooking fire.Thestraps may be made of any high strength material and shall beof contrasting color from the blanket itself.3.3.2 Attention shall be paid to the design of any holdingdevice to ensure ease of handling and hand release.3.4 Appearance and Bi-Lateral UseThe two sides of a fireblanket shall be of identical appearance,finish or color andshall give the equivalent results when tested for compliancewith Section 4.NOTE1It is important not only that either side of fire blanket can beexposed to the fire or other hazard with equal effectiveness,but also thatno doubt be created in the mind of the user at the moment of emergencyuse as to which side of the fire blanket to apply to the hazard.3.5 Resistance to Fraying or TearingThe edges of cook-ing fire suppression blankets shall not fray or tear duringtesting for compliance with 4.3.1,4.3.2,4.4.4,and 4.5.1.5.4.Test Methods4.1 Sampling and Sequence of Testing:4.1.1 A minimum of nine cooking fire suppression blanketsis required.Identify and mark the cooking fire suppressionblankets as No.1 to 9 and the two sides as(a)and(b).4.1.1.1 Cooking fire suppression blankets which contain aseam shall be tested both on and off the seam and,where theseam is tested,in the most unfavorable condition.Tests shall becarried out using a single thickness of cooking fire suppressionblankets.4.1.2 Use any fire blanket as required for the nondestructiveexaminations required in Section 4.Use cooking fire suppres-sion blankets No.1,2,and 3 for testing to 4.5.1 in the sequenceof 1(a),2(b),3(a).Use cooking fire suppression blankets 4,5and 6 for testing to 4.4 in sequence of 4(a),5(b),and 6(a).Usecooking fire suppression blankets 7,8 and 9 for testing to 4.5.2in sequence of 7(a),8(b),and 9(a).4.2 Conditioning:4.2.1 Condition cooking fire suppression blankets for test-ing for 48 h so that they are in equilibrium with air at 20 6 5Cand at a relative humidity of 50 to 70%.After conditioning,donot expose the blanket to air at different temperature or relativehumidity for longer than 5 min before testing.Keep the fireblanket in a sealed plastic bag or other conditioning containeruntil testing if it is necessary to transport it any distance to thetest site.1This specification is under the jurisdiction of ASTM Committee F15 onConsumer Products and is the direct responsibility of Subcommittee F15.46 on FireSuppression Towels.Current edition approved April 1,2013.Published August 2013.Originallyapproved in 1999.Last previous edition approved in 2005 as F1989 05.DOI:10.1520/F1989-05R13.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 4.2.2 Store fire blanket for testing in their containers,or inthe recommended storage condition for 24 h immediately priorto the testing for conformity with the requirements of Section4.4.2.3 Except where otherwise specified,tests shall be car-ried out at 20 6 10C.4.3 General Tests:4.3.1 Flexibility Test