分享
ASTM_F_543_-_17.pdf
下载文档

ID:189215

大小:645.63KB

页数:22页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_F_543_ _17
Designation:F54317Standard Specification and Test Methods forMetallic Medical Bone Screws1This standard is issued under the fixed designation F543;the number immediately following the designation indicates the year of originaladoption or,in the case of revision,the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This specification provides requirements for materials,finish and marking,care and handling,and the acceptabledimensions and tolerances for metallic bone screws that areimplanted into bone.The dimensions and tolerances in thisspecification are applicable only to metallic bone screwsdescribed in this specification.1.2 This specification provides performance considerationsand standard test methods for measuring mechanical propertiesin torsion of metallic bone screws that are implanted into bone.These test methods may also be applicable to other screwsbesides those whose dimensions and tolerances are specifiedhere.The following annexes are included:1.2.1 Annex A1Test Method for Determining the Tor-sional Properties of Metallic Bone Screws.1.2.2 Annex A2Test Method for Driving Torque of Medi-cal Bone Screws.1.2.3 Annex A3Test Method for Determining the AxialPullout Strength of Medical Bone Screws.1.2.4 Annex A4Test Method for Determining the Self-Tapping Performance of Self-Tapping Medical Bone Screws.1.2.5 Annex A5Specifications for Type HA and Type HBMetallic Bone Screws.1.2.6 Annex A6Specifications for Type HC and Type HDMetallic Bone Screws.1.2.7 Annex A7Specifications for Metallic Bone ScrewDrive Connections.1.3 This specification is based,in part,upon ISO 5835,ISO6475,and ISO 9268.1.4 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.5 Multiple test methods are included in this standard.However,the user is not necessarily obligated to test using allof the described methods.Instead,the user should only select,with justification,test methods that are appropriate for aparticular device design.This may only be a subset of theherein described test methods.1.6 This standard may involve the use of hazardousmaterials,operations,and equipment.This standard does notpurport to address all of the safety concerns,if any,associatedwith its use.It is the responsibility of the user of this standardto establish appropriate safety and health practices anddetermine the applicability of regulatory limitations prior touse.1.7 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2E4 Practices for Force Verification of Testing MachinesE6 Terminology Relating to Methods of Mechanical TestingE8 Test Methods for Tension Testing of Metallic MaterialsE122 Practice for Calculating Sample Size to Estimate,WithSpecified Precision,the Average for a Characteristic of aLot or ProcessF67 Specification for Unalloyed Titanium,for Surgical Im-plant Applications(UNS R50250,UNS R50400,UNSR50550,UNS R50700)F86 Practice for Surface Preparation and Marking of Metal-lic Surgical ImplantsF116 Specification for Medical Screwdriver BitsF136 Specification for Wrought Titanium-6Aluminum-4Vanadium ELI(Extra Low Interstitial)Alloy for SurgicalImplant Applications(UNS R56401)F138 Specification for Wrought 18Chromium-14Nickel-2.5Molybdenum Stainless Steel Bar and Wire for SurgicalImplants(UNS S31673)F565 Practice for Care and Handling of Orthopedic Implantsand Instruments1This specification is under the jurisdiction of ASTM Committee F04 onMedical and Surgical Materials and Devices and is the direct responsibility ofSubcommittee F04.21 on Osteosynthesis.Current edition approved March 1,2017.Published April 2017.Originallyapproved in 1977.Last previous edition approved in 2013 as F543 131.DOI:10.1520/F0543-17.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 F620 Specification for Titanium Alloy Forgings for SurgicalImplants in the Alpha Plus Beta ConditionF799 Specification for Cobalt-28Chromium-6MolybdenumAlloy Forgings for Surgical Implants(UNS R31537

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开