温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_F_2675_
_F_2675M_
_13
Designation:F2675/F2675M13Standard Test Method forDetermining Arc Ratings of Hand Protective ProductsDeveloped and Used for Electrical Arc Flash Protection1This standard is issued under the fixed designation F2675/F2675M;the number immediately following the designation indicates the yearof original adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.A superscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method is used to determine the arc rating ofhand protective products in the form of gloves,glove materials,glove material systems,or other protective products designedto fit on the hand and specifically intended for electric arc flashprotection use as protective accessories for workers exposed toelectric arc heat flux values from 84 to 25,120 kW/m22 to 600cal/cm2s.1.2 This test method will determine the arc rating of handprotective products made of materials which meet the follow-ing requirements for flame resistance:less than 150 mm 6 in.char length,less than 2 s afterflame and no melt and drip whentested in accordance with Test Method D6413 or receive areported 50%probability of ignition of a material or flam-mable underlayer(see definition of ignition50)by this method.1.2.1 It is the intent of this test method to be used for handprotective products which are flame resistant or which have anadequate flame resistance for the required hazard(see 1.2).Non flame resistant hand protective products may be used asunder layers in multiple-layer systems or tested for ignitionprobability.1.2.2 It is not the intent of this test method to be used forglove materials,which have been tested by Test MethodF1959/F1959M as flat panels of material then sewn into handprotective products.Materials for hand protective products,which are not normally produced in flat panels or whichdisplay shrinkage making the material unacceptable to test onpanels,shall be tested using this standard.1.2.3 Rubber insulating gloves meeting Specification D120and leather protectors meeting Specification F696 are notcovered by this test method and are specifically excluded fromits Scope.1.2.4 Hand protective products tested by this method arenew and ratings received by this method may be reduced oreliminated by hydrocarbon loading(gasoline,diesel fuel,transformer oil,etc.),sweat,dirt,grease,or other contaminants.The end user takes responsibility for use of hand protectiveproducts tested by this method when contaminated in such amanner which could reduce or eliminate the arc rating of thehand protective products.1.2.5 Gloves tested by this method provide no protectionfrom electric shock.Insulated gloves for protection fromelectric shock are addressed under other standards includingASTM D120.This test method is designed to provide infor-mation for gloves used for electric arc protection only.This testmethod is not suitable for determining electrical protectiveproperties of hand protective products.1.3 This test method is used to measure and describe theproperties of hand protective products in response to convec-tive and radiant energy generated by an electric arc undercontrolled laboratory conditions.1.4 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard.The values stated ineach system may not be exact equivalents;therefore,eachsystem shall be used independently of the other.Combiningvalues from the two systems may result in non-conformancewith the standard.1.5 This test method does not apply to electrical contact orelectrical shock hazards.1.6 This standard shall not be used to describe or appraisethe fire hazard or fire risk of materials,products,or assembliesunder actual fire conditions.However,results of this test maybe used as elements of a fire assessment that takes into account1This test method is under the jurisdiction of ASTM Committee F18 onElectrical Protective Equipment for Workers and is the direct responsibility ofSubcommittee F18.65 on Wearing Apparel.Current edition approved June 1,2013.Published July 2013.DOI:10.1520/F2675_F2675M-13.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 all of the factors,which are pertinent to an assessment of thefire hazard of a particular end use.1.7 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.For specificprecautions,see Section 7.2.Referenced Documents2.1 ASTM Standards:2D120 Specification for Rubber Insulating GlovesD123 Terminology Relating to TextilesD4391 Terminology Relating to The Burning Behavior ofTextilesD6413 Test Method for Flame Resistance of Textiles(Ver-tical Test)E457 Test Method for Measuring Heat-Transfer Rate Usinga Therm