分享
ASTM_F_1612_-_95_2005.pdf
下载文档

ID:188748

大小:106.88KB

页数:6页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_F_1612_ _95_2005
Designation:F 1612 95(Reapproved 2005)Standard Practice forCyclic Fatigue Testing of Metallic Stemmed Hip ArthroplastyFemoral Components with Torsion1This standard is issued under the fixed designation F 1612;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon(e)indicates an editorial change since the last revision or reapproval.1.Scope1.1 This practice covers a method for the fatigue testing ofmetallic stemmed femoral components used in hip arthroplasty.The described method is intended to be used for evaluation incomparisons of various designs and materials used forstemmed femoral components used in the arthroplasty.Thispractice covers procedures for the performance of fatigue testsusing(as a forcing function)a periodic constant amplitudeforce.1.2 This practice applies primarily to one-piece prosthesesand femoral stems with modular heads,with the head in place.Such prostheses should not have an anterior-posterior A-P bowor a medial-lateral M-L bow,and they should have a nearlystraight section on the distal 50 mm of the stem.This practicemay require modifications to accommodate other femoral stemdesigns.1.3 The values stated in SI units are to be regarded as thestandard.1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2E 4 Practices for Force Verification of Testing MachinesE 466 Practice for Conducting Force Controlled ConstantAmplitude Axial Fatigue Tests of Metallic MaterialsE 467 Practice for Verification of Constant Amplitude Dy-namic Forces in an Axial Fatigue Testing SystemE 468 Practice for Presentation of Constant Amplitude Fa-tigue Test Results for Metallic MaterialsE 1150 Definitions of Terms Relating to Fatigue32.2ISO Document:4ISO 7206-3(1988)Stem Test3.Terminology(see Fig.1 and Fig.2)3.1 Definitions of Terms Specific to This Standard:3.1.1 cantilever planea plane perpendicular to the line ofload application at the level on the stem at which the stembecomes unsupported.3.1.2 distal stem axisthe centerline in the A-P projectionand the M-L projection of the most distal 50 mm of the stem.3.1.3 estimated maximum bending momentthe maximumcompressive load times the unloaded moment arm.3.1.4 geometric centroid(cantilever plane)the point in across-sectional area of the cantilever plane whose coordinatesare the mean values of the coordinates of all of the points in thearea.3.1.5 line of load applicationthe loading axis of the testmachine.3.1.6 R valuethe ratio of the minimum force to themaximum force,R 5minimum forcemaximum force3.1.7 Reference Line L1:3.1.7.1 distal stem axisthe M-L centerline of the mostdistal 50 mm of stem in the A-P projection.3.1.8 Reference Line L2:3.1.8.1 collared devicethe plane of the distal side of thecollar in the A-P projection.3.1.8.2 collarless devicethe resection plane recommendedfor the device in the A-P projection.3.1.9 Reference Point P1the spherical center of the pros-thesis head.3.1.10 Reference Point P3:1This practice is under the jurisdiction ofASTM Committee F04 on Medical andSurgical Materials and Devices and is the direct responsibility of SubcommitteeF04.22 on Arthroplasty.Current edition approved Oct.1,2005.Published October 2005.Originallyapproved in 1995.Last previous edition approved in 2000 as F 1612 95(2000).2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Withdrawn.4Available from American National Standards Institute(ANSI),25 W.43rd St.,4th Floor,New York,NY 10036.1Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959,United States.3.1.10.1 collared devicethe intersection of the principalaxis of the collar(L2)with the medial surface of the stem in theA-P projection.3.1.10.2 collarless devicethe intersection of the resectionplane(L2)with the medial surface of the stem in the A-Pprojection.3.1.11 Reference Point P4the distal tip of the stem.3.1.12 Reference Point P65 the intersection of the canti-lever plane with the medial surface of the stem in the A-Pprojection.3.1.13 stem reference anglesSince the distal stem axis isobscurred by the grouting agent after preparation of the testsample,the stem reference angles are to be used to measure therepeatability of the stem orientation.They may also be used toestimate the actual orientation of the distal stem to the line ofload application if the stem geometry is well known.3.1.13.1 X(M-L)the angle between the stem referenceline and line of load applica

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开