分享
ASTM_F_1115_-_95_2008e1.pdf
下载文档

ID:188557

大小:1.68MB

页数:12页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_F_1115_ _95_2008e1
Designation:F111595(Reapproved 2008)1Standard Test Method forDetermining the Carbon Dioxide Loss of BeverageContainers1This standard is issued under the fixed designation F1115;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1NOTEEditorial corrections were made throughout in March 2008.1.Scope1.1 The objective of this test method is to determine thecarbon dioxide(CO2)loss from plastic beverage containersafter a specified period of storage time.1.2 Factors contributing to this pressure loss are volumeexpansion and the gas transport characteristics of the packageincluding permeation and leakage.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2D1129 Terminology Relating to WaterD1193 Specification for Reagent WaterE380 Practice for Use of the International System of Units(SI)(the Modernized Metric System)(Withdrawn 1997)33.Terminology3.1 Units,symbols,and abbreviations used in this testmethod are those recommended by Practice E380.3.2 Definitions of Terms Specific to This Standard:3.2.1 carbonation volumethe volume of CO2(at 0C,1atm pressure)that is dissolved in the carbonated water,dividedby the volume of the liquid(based on water volume at 3.98Cequals 1.000 g/cm3).The conversion of pressure to carbon-ation volumes should be made using a carbonation volumestable.Atable for carbonated water would not necessarily applyto liquids containing additional substances,such as carbonatedbeverages containing sugar.3.2.2 initial pressurethe equilibrium pressure in the testbottles as measured at 24 h after filling with carbonated water.(The filled bottles are allowed to stand for 24 h to obtaintemperature equilibrium with the test environment and to allowtime for pressure adjustment and equilibration of the CO2inthe headspace and liquid.)3.2.3 samplea set of bottles produced on the same equip-ment in a single run and using the same material and processconditions.Bottles should represent normal thickness distribu-tion.3.2.4 shelf lifethe number of weeks a sample set of bottlesretain a specified carbonation level,or a percent of the initiallevel.3.2.5 pressure monitoring devicea pressure gage or trans-ducer assembly with support electronics for indicating internalpressure level of the bottle.This device is used with brassclosure fitting-equipped bottles.3.2.5.1 temperature monitoring devicea thermocouplewith support electronics(same equipment as described in7.2.2).A precision glass thermometer may be used provided abottle filled with noncarbonated water is used as a control ineach sample set(Procedure A).3.2.6 Terriss CO2Analyzeran electronic unit that willpierce the roll-on closure and automatically read pressure andtemperature and calculate volume of gas(Procedure B).3.2.7 Zahm-Nagle Pressure Testera unit that manuallypierces the closure and measures container pressure;an at-tached thermometer is then used to measure temperature(Procedure B).3.2.8 support ringa protrusion below the bottle finishwhich is used to support or stabilize the bottle during fillingand capping.3.2.9 finishthe threaded part of the bottle which receivesthe cap.1This test method is under the jurisdiction ofASTM Committee F02 on FlexibleBarrier Packaging and is the direct responsibility of Subcommittee F02.10 onPermeation.Current edition approved Feb.1,2008.Published March 2008.Originallyapproved in 1987.Last previous edition approved in 2001 as F1115 95(2001).DOI:10.1520/F1115-95R08E01.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 3.3 For other terms used in this test method,refer toTerminology D1129.4.Summary of Test Method4.1 Test bottles are filled with carbonated water or beverageand,after closure application,are exposed to test environmentsfor specified time periods.By periodically measuring the initialand final carbonation levels in the container,the carbonationloss and carbonation transfer rate can be calculated.5.Significance and Use5.1 Two procedures,A and B,are outlined in this testmethod.Procedure A is used most often for development ofvarious beverage container designs to determine the functionalcharacteristics of the package in regard to shelf life.Proc

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开