TM_F_1018_
_87a_2010
Designation:F101887a(Reapproved 2010)An American National StandardStandard Specification forSteel Emergency Gear Stowage Locker1This standard is issued under the fixed designation F1018;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This specification covers the design,material,andmanufacture of steel emergency gear stowage lockers.1.2 Emergency gear lockers shall be of four types(seeSection 3).1.3 The values stated in inch-pound units are to be regardedas the standard.The values given in parentheses are forinformation only.2.Referenced Documents2.1 ASTM Standards:2A36/A36M Specification for Carbon Structural SteelA276 Specification for Stainless Steel Bars and ShapesA366/A366M Specification for Commercial Steel(CS)Sheet,Carbon,(0.15 Maximum Percent)Cold-Rolled(Withdrawn 2000)3A513 Specification for Electric-Resistance-Welded Carbonand Alloy Steel Mechanical TubingA563 Specification for Carbon and Alloy Steel NutsB36/B36M Specification for Brass Plate,Sheet,Strip,AndRolled BarB124/B124M Specification for Copper and Copper AlloyForging Rod,Bar,and ShapesB176 Specification for Copper-Alloy Die Castings2.2 ANSI Standards:4ANSI B18.1.1 Small Solid RivetsANSI B18.6.3 Slotted and Recessed Head Machine Screwsand Machine Screw NutsANSI B18.21.1 Lock WashersANSI B27.2 Plain Washers2.3 Other Documents:ABS Rules for Building and Classing Steel Vessels5SSPC Specification 66AWS D1.1 Welding Code73.Classification3.1 Emergency gear lockers shall be classified in four typesas follows:3.1.1 Type 1For stowage of one complete firemans outfit,conforming to all requirements of all sections,figures,anddetails of this specification.3.1.2 Type 2For stowage of two complete firemensoutfits,conforming to all requirements of all sections,figures,and details of this specification.3.1.3 Type 3For stowage of one complete firemans outfit,with locker dimensions in accordance with Figs.2,3,and 4(dimensions only),and conforming to the requirements of 3.2,3.3,4.1,5.2.4,and Sections 6 and 7 inclusive.3.1.4 Type 4For stowage of two complete firemensoutfits,with locker dimensions in accordance with Figs.2,3,and 4(dimensions only),and conforming to the requirementsof 3.2,3.3,4.1,5.2.4,and Sections 6 and 7 inclusive.3.2 One complete firemans outfit shall consist of thefollowing emergency gear(not included in this specification):3.2.1 Self-contained breathing apparatus(24 by 14 by 11 in.(610 by 355 by 280 mm).3.2.2 Recharge air tank(7-in.(180-mm)diameter by 22 in.(560 mm)long).3.2.3 Set protective clothing,including helmet,gloves,andboots.3.2.4 Lifeline(150 ft(45 m),18 by 18 by 10 in.(455 by 455by 255 mm).3.2.5 Three-cell,explosion-proof flashlight with spare cells.3.2.6 Flame safety lamp.3.2.7 Fire axe.1This specification is under the jurisdiction of ASTM Committee F25 on Shipsand Marine Technology and is the direct responsibility of Subcommittee F25.03 onOutfitting and Deck Machinery.Current edition approved May 1,2010.Published June 2010.Originallyapproved in 1986.Last previous edition approved in 2004 as F1018 87a(2004).DOI:10.1520/F1018-87AR10.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.4Available from American National Standards Institute(ANSI),25 W.43rd St.,4th Floor,New York,NY 10036,http:/www.ansi.org.5Available from American Bureau of Shipping(ABS),ABS Plaza,16855Northchase Dr.,Houston,TX 77060,http:/www.eagle.org.6Available from Society for Protective Coatings(SSPC),40 24th St.,6th Floor,Pittsburgh,PA 15222-4656,http:/www.sspc.org.7Available from American Welding Society(AWS),550 NW LeJeune Rd.,Miami,FL 33126,http:/www.aws.org.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 3.3 In addition to the equipment listed in 3.2,each lockershall contain space for the following(not part of this specifi-cation):3.3.1 First-aid kit,(1),(10 by 10 by 7 in.(255 by 255 by 180mm).3.3.2 Spare air tanks,as space allows(see Figs.2,3,and 4).4.Ordering Information4.1 Order using this ASTM designation,year of issue,locker type,and finish.5.Materials and Manufacture5.1 MaterialsMaterials shall be as specified in Table 1.5.2 Manufacture:5.2.1 Mandatory dimensions and construction details forTypes 1 and 2 are as depicted in Figs.1-9.5.2.2 Mandatory dimensions for Types 3 and 4 are as shownin Fig.2,Fig.3,and Fig.5,respectively,and applicable detailsof Sections“A-A and“B-B.Alternative construction detailsare permissible.TABLE 1 Parts List for Locker Type 2NOTE11 in.=25.4 mm.Descripti