分享
ASTM_F_1349_-_08_2019.pdf
下载文档

ID:188080

大小:192.03KB

页数:6页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_F_1349_ _08_2019
Designation:F134908(Reapproved 2019)Standard Test Method forNonvolatile Ultraviolet(UV)Absorbing Extractables fromMicrowave Susceptors1This standard is issued under the fixed designation F1349;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method covers the determination of nonpolarand relatively polar ultraviolet(UV)absorbing componentsthat may migrate from microwave susceptor packaging intofood simulants,such as corn oil and Miglyol 812.1.2 This test method has been collaboratively studied usingbilaminate susceptors constructed of paperboard,adhesive,anda layer of polyethylene terephthalate polymer(PETE)suscep-tor.Adhesive and PETE related compounds were quantitatedusing this test method.1.3 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.Specific warning statements are given in 4.3.2.3.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2F874 Test Method for Temperature Measurement and Pro-filing for Microwave SusceptorsF1317 Test Method for Calibration of Microwave Ovens3.Apparatus and Reagents3.1 Microwave Oven,700 6 35 W,calibrated.Refer to TestMethod F1317.3.2 High-Pressure Liquid Chromatograph(HPLC),consist-ing of:3.2.1 Pump,capable of 1.5 mL/min with flow precision62%.3.2.2 Injector,loop-type,equipped with 20-L loop.3.2.3 Guard Column,C8,5 m.3.2.4 Analytical Column,C8,5 m,250 by 4.6 mm.3.2.5 Detector-UV Absorbance,set for 254 nm.Adjustsensitivity to give a 70 to 100%of full scale peak for the 5-ppm dimethylterephthalate DMT standard.3.2.6 Gradient Program,4 to 60%Mobile Phase B in 8min;60 to 70%B in 9 min;70 to 100%B in 7 min;100%Bfor 11 min;100 to 4%B in 5 min;4%B for minimum of 5min.Where Mobile Phase A(v/v)is 85+15+0.25%water:acetonitrile:acetic acid,and Mobile Phase B(v/v)is15+85%water:acetonitrile.3.2.7 Peak Area Integration SystemInitialize data acqui-sition or integration system,or both,from 5 to 35 min duringthe separation.3.3 Hexane,LC/UV grade.3.4 Acetonitrile,LC/UV grade.3.5 Corn OilObtain corn oil that is as pure and fresh aspossible to minimize peaks in nonvolatiles extractables chro-matogram.Alternatively,Miglyol 812(a fractionated coconutoil)or synthetic fat simulant HB 307 can be used as a substitutefor corn oil.3.6 Dimethylacetamide(DMAC),LC/UV grade.3.7 Conical Bottom Test Tubes,50 mL,graduated.3.8 Bishydroxyethyleneterephthalate(BHET).3.9 Diethylterephthalate(DET).3.10 Dimethylterephthalate(DMT).3.11 Fluoroptic Thermometry System.3.12 Temperature Probes,four,high temperature.1This test method is under the jurisdiction of ASTM Committee F02 on PrimaryBarrier Packaging and is the direct responsibility of Subcommittee F02.15 onChemical/Safety Properties.Current edition approved March 1,2019.Published May 2019.Originallyapproved in 1991.Last previous edition approved in 2014 as F1349 08(2014).DOI:10.1520/F1349-19.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 3.13 Glass Beads,3 to 4 mm,clean thoroughly by rinsingwith methylene chloride followed by soaking for 30 min inacetonitrile.Dry thoroughly before using.3.14 Recommended Microwave Nonvolatile ExtractionCellWaldorf Polytetrafluoroethylene cell.3(See Figs.1-3).This cell must be constructed by a machine shop experiencedin working with polytetrafluoroethylene(PTFE).After micro-waving oil in the cell,the cell should be rinsed with methylenechloride to remove residual oil and prevent carry-over.3.15 Solvent Concentration ApparatusKuderna-Danishevaporative concentrator,rotory evaporator;or Zymark Tur-boVap at a n

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开