TM_F_1197_
_19
Designation:F119719An American National StandardStandard Specification forSliding Watertight Door Control Systems1This standard is issued under the fixed designation F1197;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This specification covers the design,manufacture,andtesting of controls and operating mechanisms for use withsliding watertight doors meeting the requirements of Specifi-cation F1196.1.2 The values stated in inch-pound units are to be regardedas standard.The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2A312/A312M Specification for Seamless,Welded,andHeavily Cold Worked Austenitic Stainless Steel PipesF1196 Specification for Sliding Watertight Door Assemblies2.2 IEEE Standards:3IEEE 45 Recommended Practice for Electrical Installationson ShipboardIEEE 100 IEEE Standard Dictionary of Electrical and Elec-tronic Terms2.3 SAE Standards:4J524 Seamless Low Carbon Steel Tubing Annealed forBending and FlaringJ525 Welded and Cold Drawn Low Carbon Steel TubingAnnealed for Bending and Flaring2.4 Military Specification:5MIL-DTL-901 Shock Test,H.I.(High Impact);ShipboardMachinery,Equipment and Systems,Requirements for2.5 ASME Publication:6Section VIII,Division 1 ASME Boiler and Pressure VesselCode,Pressure Vessels2.6 NEMA Publication:7Publication Number IS1.1 Enclosures for Industrial Controlsand Systems3.Terminology3.1 Definitions:3.1.1 control station,na location from which a slidingwatertight door may be closed.3.1.2 door control,nthe device that must be physicallyactivated by the operator to initiate the opening or closing of asliding watertight door.3.1.3 door control system,nthe system of componentsnecessary to operate a sliding watertight door,consisting of thedoor control,operating mechanism,and interconnecting com-ponents.3.1.4 electrical control voltage,nthe voltage applied tothe door controls,indicators,and alarms.3.1.5 electrical system voltage,nthe voltage generated bythe electrical power sources at which the operating mechanismwill operate.3.1.6 interconnecting components,nthose componentsbetween the door control and the operating mechanism neces-sary to cause the operating mechanism to move a slidingwatertight door as directed by the door control or between thedoor and the remote indicator.Interconnecting componentsform a mechanical,hydraulic,or electrical system between thecontrol station and the door and between the door and theremote indicator.1This specification is under the jurisdiction of F25 on Ships and MarineTechnology and is the direct responsibility of F25.03 on Outfitting and DeckMachinery.Current edition approved March 1,2019.Published April 2019.Originallyapproved in 1989.Last previous edition approved in 2012 as F1197 00(2012).DOI:10.1520/F1197-19.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from Institute of Electrical and Electronics Engineers,Inc.(IEEE),445 Hoes Ln.,P.O.Box 1331,Piscataway,NJ 08854-1331,http:/www.ieee.org.4Available from Society of Automotive Engineers(SAE),400 CommonwealthDr.,Warrendale,PA 15096-0001,http:/www.sae.org.5Available from DLA Document Services,Building 4/D,700 Robbins Ave.,Philadelphia,PA 19111-5094,http:/quicksearch.dla.mil.6Available from American Society of Mechanical Engineers(ASME),ASMEInternational Headquarters,Two Park Ave.,New York,NY 10016-5990,http:/www.asme.org.7Available from National Electrical Manufacturers Association(NEMA),1300N.17th St.,Suite 1752,Rosslyn,VA 22209,http:/www.nema.org.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 3.1.7 local control station,na location adjacent to asliding watertight door from which the door may be opened orclosed.3.1.8 manual control,na door control that requires theoperator to apply a continuous cyclic force,for example,theturning