分享
ASTM_E_3051_-_16.pdf
下载文档

ID:187993

大小:125.59KB

页数:10页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_E_3051_ _16
Designation:E305116Standard Guide forSpecification,Design,Verification,and Application ofSingle-Use Systems in Pharmaceutical andBiopharmaceutical Manufacturing1This standard is issued under the fixed designation E3051;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This guide is intended as a complement to Guide E2500.1.2 This guide is applicable to the range of manufacturingsystems described in Guide E2500,specifically all elements ofsingle-use systems,or hybrids of single-use and traditionalcomponents,used for the manufacturing of pharmaceutical andbiopharmaceuticalproducts,including:materialsofconstruction,components,assembly,manifolds,supportingutilities,associated process monitoring and control systems,automation systems,and controlled environment that have thepotential to affect product quality and patient safety.1.3 This guide is applicable for the implementation ofchanges to manufacturing system design for existing systems.It may be used for continuous improvement and changes inoperation from clinical through to commercial scale.1.4 For brevity,single-use systems are referred to as SUSthroughout the rest of this guide.1.5 The approach may be applied by the end user,thesupplier of SUS,and raw materials sub-suppliers further backin the supply chain.1.6 This guide is not intended to apply to the use ofsingle-use technology for packaging,primary containers,com-bination products(products composed of any combination of adrug,device,or biological product)or devices.1.7 This guide does not address specific local requirements,which remain the responsibility of the end user.1.8 This guide does not address employee health and safety,environmental,nor other good engineering and manufacturingpractices(GXP)requirements.This standard does not purportto address all of the safety concerns,if any,associated with itsuse.It is the responsibility of the user of this standard toestablish appropriate safety and health practices and deter-mine the applicability of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2D4169 Practice for Performance Testing of Shipping Con-tainers and SystemsE2363 Terminology Relating to Process Analytical Technol-ogy in the Pharmaceutical IndustryE2500 Guide for Specification,Design,and Verification ofPharmaceutical and Biopharmaceutical ManufacturingSystems and Equipment2.2 United States Pharmacopeia:3USP Particulate Matter in InjectionsUSP Visible Particulates in Injections2.3 International Conference on Harmonization of Techni-cal Requirements for Registration of Pharmaceuticals forHuman Use(ICH):4ICH Q7 Good Manufacturing Practice Guide for ActivePharmaceutical IngredientsICH Q8(R2)Pharmaceutical DevelopmentICH Q9 Quality Risk ManagementICH Q10 Pharmaceutical Quality System2.4 ISO Standards:5ISO 13485:2003 Medical DevicesQuality ManagementSystemsRequirements for Regulatory PurposesISO 14644 Cleanrooms and Associated Controlled Environ-mentsISTA 3A General Simulation Performance tests2.5 U.S.Food and Drug Administration(USFDA):6Guidance for Industry Process Validation:General Prin-ciples and Practices1This guide is under the jurisdiction of ASTM Committee E55 on Manufactureof Pharmaceutical and Biopharmaceutical Products and is the direct responsibility ofSubcommittee E55.03 on General Pharmaceutical Standards.Current edition approved Feb.1,2016.Published March 2016.DOI:10.1520/E3051-16.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from U.S.Pharmacopeial Convention(USP),12601 TwinbrookPkwy.,Rockville,MD 20852-1790,http:/www.usp.org.4Available from International Conference on Harmonisation of TechnicalRequirements for Registration of Pharmaceuticals for Human Use(ICH),ICHSecretariat,9,chemin des Mines,P.O.Box 195,1211 Geneva 20,Switzerland,http:/www.ich.org.5Available from American National Standards Institute(ANSI),25 W.43rd St.,4th Floor,New York,NY 10036,http:/www.ansi.org.6Available from U.S.Food and Drug Administration(FDA),10903 NewHampshire Ave.,Silver Spring,MD 20993,http:/www.fda.gov.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 Pharmaceutical cGMPs for the 21st Century,A Risk-BasedApproach2.6 European Medicine Agency:Commission Directive 2003/94/EC of 8 October 20032.7 Other Publications:PDA Technical Report No.66 Application of Single-UseSystems in Pharmaceutical ManufacturingConsensus QualityAgreement Template for Single-Use Bio-pharmaceutical Manufacturing Products BioProcess Sys-tems Alliance7TAPPI Standard Practice T 564 sp-113.Terminology3

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开