分享
ASTM_C_67-14.pdf
下载文档

ID:186084

大小:4.26MB

页数:16页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_C_67 14
4C67-14be tested for each 500 tons(453.6 Mg)or fraction thereof.In6.2.1 Support the test specimen flatwise unless specified andno case shall less than five tile be taken.Additional specimensreported otherwise(that is,apply the load in the direction of theare taken at the discretion of the purchaser.depth of the unit)on a span approximately I in.(25.4 mm)less4.3 Identification-Each specimen shall be marked so that itthan the basic unit length and loaded at midspan.Specimensis identifiable at any time.Markings shall cover not more thanhaving recesses(panels or depressions)shall be placed so that5 of the superficial area of the specimen.such recesses are on the compression side.Apply the load tothe upper surface of the specimen through a steel bearing plate4 in.(6.35 mm)in thickness and 1%in.(38.10 mm)in width5.Specimen Preparationand of a length at least equal to the width of the specimen.5.1 Drying and Cooling:6.2.2 Make sure the supports for the test specimen are free5.1.1 Drying-Dry the test specimens in a ventilated oven atto rotate in the longitudinal and transverse directions of the test230 to 239F(110 to 115C)for not less than 24 h and untilspecimen and adjust them so that they will exert no force intwo successive weighings at intervals of 2 h show an incrementthese directions.of loss not greater than 0.2 of the last previously determined6.2.3 Speed of Testing-The rate of loading shall not exceedweight of the specimen.2000 Ibf(8896 N)/min.This requirement is considered as5.1.2 Cooling-After drying,cool the specimens in a dryingbeing met when the speed of the moving head of the testingroom maintained at a temperature of 75+15F(24 8C),machine immediately prior to application of the load is notwith a relative humidity between 30 and 70%.Store the unitsmore than 0.05 in.(1.27 mm)/minfree from drafts,unstacked,with separate placement,for aperiod of at least 4 h and until the surface temperature is within6.3 Calculation and Report:5F(2.8C)of the drying room temperature.Do not use6.3.1 Calculate and report the modulus of rupture of eachspecimens noticeably warm to the touch for any test requiringspecimen to the nearest 1 psi(0.01 MPa)as follows:dry units.The specimens shall be stored in the drying roomS=3W(1/2-x)/bd(1)with the required temperature and humidity maintained untilwhere:tested.Smodulus of rupture of the specimen at the plane of5.1.2.1 An alternative method of cooling the specimens tofailure,Ib/in.(Pa),approximate room temperature is permitted as follows:StoreW=maximum load indicated by the testing machine,Ibfunits,unstacked,with separate placement,in a ventilated roomN),maintained at a temperature of 75+15F(24+8C),with adistance between the supports,in.(mm),relative humidity between 30 and 70%for a period of 4 h andb net width.(face to face minus voids).of the specimenuntil the surface temperature is within 5F(2.8C)of theat the plane of failure,in.(mm).ventilated room temperature,with a current of air from and depth.(bed surface to bed surface).of the specimen atelectric fan passing over them for a period of at least 2 hours.the plane of failure,in.(mm),andThe specimens shall be stored in the ventilated room with theaverage distance from the midspan of the specimen torequired temperature and humidity maintained until tested.the plane of failure measured in the direction of the5.2 Weight Determination:span along the centerline of the bed surface subjected to5.2.1 Weigh five full size specimens that have been driedtension,in.(mm).and cooled(see 5.1).The scale or balance used shall have a6.3.2 Calculate and report the average of the modulus ofcapacity of not less than 3000 g and shall be sensitive to 0.5 g.rupture determinations to the nearest 1 psi(0.01 MPa).5.2.2 Report results separately for each specimen to thenearest 0.1 g,with the average of all specimens tested to the7.Compressive Strengthnearest 0.1 g.7.1 Test Specimens:5.3 Removal of Silicone Coatings from Brick Units-The7.1.1 Brick-The test specimens shall consist of half bricksilicone coatings intended to be removed by this process areunits that have been dried and cooled(see 5.1).the full heightany of the various polymeric organic silicone compounds usedand width of the unit,with a length equal to one half the fullfor water-resistant coatings of brick units.Heat the brick at 950length of the unit I in.(25.4 mm),except as described below.50(5l028C)in an oxidizing atmosphere for a periodWhen the test specimen,described above,exceeds the testingof not less than 3 hours.The rate of heating and cooling shallmachine capacity,the test specimens shall consist of dry piecesnot exceed 300F(149C)per hour.of brick,the full height and width of the unit,with a length notNorE 2-Additional specimen preparation requirements for specificless than one quarter of the full length of the unit,and with atests are indicated in the individual test methods.gross cross-sectional area perpendicular to bearing not lessthan 14 in.2(90.3 cm2).Test specimens shall be obtained by6.Modulus of Rupture(Flexure Test)any method that will produce,without shattering or cracking,aspecimen with approximately plane and parallel ends.Five6.1 Test Specimens-The test specimens shall consist ofspecimens shall be tested.whole full-size units that have been dried and cooled(see 5.1).Five such specimens shall be tested.7.1.2 Structural Clay Tile-Test five tile specimens thathave been dried and cooled(see 5.1)in a bearing bed length6.2 Procedure:equal to the width 1 in.(25.4 mm);or test full-size units.ASTM Inte

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开