ASTM_DS65
1995
Atmospheric Corrosion Investigation of Aluminum-Coated,Zinc-Coated,and Copper-Bearing Steel Wire and Wire Products:A Thirty-Two Year Report Sponsored by ASTM Committee A5 on Metallic-Coated Iron and Steel Products Beryle G.Sweet Thomas C.Britton,Jr.ASTM Data Series:DS 65 Revision of STP 585A ASTM Publication Code Number(PCN):05-015950-02 m l ASTM 1916 Race Street Philadelphia,PA 19103 Printed in the U.S.A.Library of Congress Cataloging-in-Publication Data Sweet,Beryle G.Atmospheric corrosion investigation of aluminum-coated,zinc-coated,and copper-bearing steel wire and wire products:a thirty-two year report/sponsored by ASTM Committee A5 on Metallic-Coated Iron and Steel Products;Beryle G.Sweet and Thomas C.Britton,Jr.(ASTM data series;DS 65)Revision of STP 585A.ASTM publication code number(PCN):05-015950-02.ISBN 0-8031-2064-8 1.Steel wireCorrosion.2.Corrosion and anti-corrosives.I.Britton,Thomas C,1951-II.ASTM Committee A-5 on Metallic-Coated Iron and Steel Products.III.Title.IV.Series:ASTM data series publication;DS 65.TA467.S893 1995 620.1723-dc20 95-9111 CIP Copyright e 1995 AMERICAN SOCIETY FOR TESTING AND MATERIALS,Philadelphia,PA.All rights reserved.This material may not be reproduced or copied,in whole or in part,in any printed,mechanical,electronic,film,or other distribution and storage media,without the written consent of the publisher.Photocopy Rights Authorization to photocopy items for internal or personal use,or the internal or personal use of specific clients,is granted by the AMERICAN SOCIETY FOR TESTING AND MATERIALS for users registered with the Copyright Clearance Center(CCC)Transactional Reporting Service,provided that the base fee of$2.50 per copy,plus$0.50 per page is paid directly to CCC,222 Rosewood Dr.,Danvers,MA 01923;Phone:(508)750-8400;FAX:(508)750-4744.For those organizations that have been granted a photocopy license by CCC,a separate system of payment has been arranged.The fee code for users of the Transactional Reporting Service is 0-8031-2064-8/95$2.50+.50.Printed in Philadelphia,PA June 1995 Foreword Committee A5 on Metallic-Coated Iron and Steel Products1 was organized in 1907 to investigate the corrosion of iron and steel.In 1908,the Committee sponsored its first atmospheric exposure of metallic-coated wires to evaluate their corrosion resis-tance.Since this date,there have been a considerable number of test programs in-volving wire,sheet,and hardware.Of particular interest is the program initiated in 1936 and reported on in ASTM STP 290 entitled Twenty-Year Atmospheric Corrosion Investigation of Zinc-Coated and Uncoated Wire and Wire Products by Fred M.Reinhart.In June 1959,the Advisory Committee on Corrosion authorized Committee A5 to conduct atmospheric corrosion tests of aluminum coated wire and wire products at seven ASTM sites in the United States(see map on next page)and an eighth site in Warrington,England.The responsibility for the latter site was assumed by Rylands Whitecross Limited.Exposure of the wire and wire products specimens was initiated in 1961.For com-parative purposes,bare copper-bearing steel wire and zinc-coated steel wire and fab-ricated products were included in the testing program.A twelve year report on the 1961 exposure program entitled ASTM STP 585 At-mospheric Corrosion Investigation of Aluminum-Coated,Zinc-Coated,and Copper-Bearing Steel Wire and Wire Products by V.I.Kelley was published in 1975.A twenty year report on the 1961 exposure program entitled ASTM STP 585A At-mospheric Corrosion Investigation of Aluminum-Coated,Zinc-Coated,and Copper-Bearing Steel Wire and Wire Products,a Twenty-Year Report by John F.Occasione,Thomas C.Britton,Jr.,and Roy C.Collins was published in 1984.This report presents the results of 32 years of exposure for the 1961 exposure pro-gram,and was prepared by Beryle G.Sweet2 and Thomas C.Britton,Jr.3 Committee A5 was originally titled Corrosion of Iron and Steel.2Retired chairman and chief executive officer of Page Aluminized Steel Corporation,100 Monongahela Street,Monessen,PA 15062-1355.Self-employed in a consulting business under the name of Sweet Wire&Fence Associates,394 McClellan Circle,Pittsburgh,PA 15236-4106.Consulting engineer with Duke Power Company,Mail Stop WC22C,P.O.Box 1007,Charlotte,NC 28201-1007.Chairman of ASTM Subcommittee A05.15 on Wire Tests.POINT REYES,CALIF.(3805N-12257W)MANHATTAN,KANSAS(3912N-9635W)BRAZOS RIVER FREEPORT,TEXAS(2853 N-9522 W).NEWARK KEARNY,N.J.(4044 N-7406 W)STATE COLLEGE,PA(4048 N-7752 W)KURE BEACH,N.C.(3400 N-7754 W)MAP-LOCATION OF TEST SITES IN THE UNITED STATES Acknowledgments The authors wish to acknowledge and extend thanks to the following people who helped with the compilation and peer review of this document:Donald L.Deetscreek,Johnstown Wire Technologies,Johnstown,PA.Phillip C.Elser,Indiana Steel&Wire Co.,Muncie,IN.Jeffrey A.Feldman,Guardian Fence Co.,Newark,NJ.Robert M.Kain,LaQue Center for Corrosion Technology,Wrightsville Beach,NC.Kenneth E.Niewoehner,Bethlehem