温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_C_919_
_12_2017
Designation:C91912(Reapproved 2017)Standard Practice forUse of Sealants in Acoustical Applications1This standard is issued under the fixed designation C919;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This practice provides information for the use of seal-ants to reduce sound transmission characteristics of interiorwalls,ceilings,and floors by proper application of sealants tojoints,voids,and penetrations normally found in buildingconstruction,which are commonly referred to as“flankingpaths.”1.2 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.3 The committee with jurisdiction over this standard is notaware of any comparable standards published by other orga-nizations.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2C634 Terminology Relating to Building and EnvironmentalAcousticsC717 Terminology of Building Seals and SealantsC834 Specification for Latex SealantsC920 Specification for Elastomeric Joint SealantsC1193 Guide for Use of Joint SealantsC1520 Guide for Paintability of Latex SealantsC1620 Specification for Aerosol Polyurethane and AerosolLatex Foam SealantsC1642 Practice for Determining Air Leakage Rates of Aero-sol Foam Sealants and Other Construction Joint Fill andInsulation MaterialsE90 Test Method for Laboratory Measurement of AirborneSound Transmission Loss of Building Partitions andElementsE336 Test Method for Measurement of Airborne SoundAttenuation between Rooms in BuildingsE413 Classification for Rating Sound Insulation2.2 HUD Standard:3HUD Minimum Property Standards for Housing,Section4910.12.3 IBC Standard:4International Building Code(IBC),Section 12073.Terminology3.1 DefinitionsFor definitions of terms used in this rec-ommended practice,see Terminologies C717 and C634.4.Significance and Use4.1 Walls,ceilings,and floors in building construction,especially those that are of lightweight construction,and thatare designed to reduce or limit sound transmission,can haveundesirable sound transmission characteristics if care is nottaken to seal joints,voids,and penetrations that typically occur.Unsealed joints,voids,and penetrations will substantiallyincrease the sound transmission characteristics of these typesof construction.By sealing them the transmission of sound canbe substantially diminished by eliminating“flanking paths.”5.Sound Transmission Requirements5.1 The construction industry has adopted Sound Transmis-sion Class(STC)units,as defined in Terminology C634,to ratethe sound transmission properties of walls,ceilings,and floors.The STC is determined in accordance with Classification E413.The test data are obtained in accordance with Test MethodsE90 and E336.5.2 Various building and other governmental adopted codesinclude requirements for sound transmission.1This practice is under the jurisdiction of ASTM Committee C24 on BuildingSeals and Sealants and is the direct responsibility of Subcommittee C24.10 onSpecifications,Guides and Practices.Current edition approved June 1,2017.Published June 2017.Originallyapproved in 1979.Last previous edition approved in 2012 as C919 12.DOI:10.1520/C0919-17.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from Superintendent of Documents,U.S.Government PrintingOffice,Washington,DC 20402.4Available from International Code Council(ICC),500 New Jersey Ave.,NW,6th Floor,Washington,DC 20001,http:/www.iccsafe.org.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 5.2.1 For example,the International Building Code(IBC),Section 1207,has requirements for the amount of sound that isallowed to be transmitted through the interior walls,partitions,and floor and ceiling assemblies between adjacent dwellingunits and between