分享
ASTM_C_1351M_-_96_2017.pdf
下载文档

ID:185178

大小:131.33KB

页数:4页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_C_1351M_ _96_2017
Designation:C1351M96(Reapproved 2017)Standard Test Method forMeasurement of Viscosity of Glass Between 104Pas and108Pas by Viscous Compression of a Solid Right CylinderMetric1This standard is issued under the fixed designation C1351M;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method covers the determination of the viscos-ity of glass from 104Pas to 108Pas by measuring the rate ofviscous compression of a small,solid cylinder.21.2 The values stated in SI units are to be regarded as thestandard.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:3C338 Test Method for Softening Point of GlassC965 Practice for Measuring Viscosity of Glass Above theSoftening PointC1350M Test Method for Measurement of Viscosity ofGlass Between Softening Point and Annealing Range(Approximately 108Pas to Approximately 1013Pas)byBeam Bending(Metric)3.Terminology3.1 parallel plate viscometera device used to determinethe viscosity of glass from approximately 104Pas to 108Pasby measuring the rate of change in thickness of a cylindricalspecimen between parallel plates moving perpendicular to theircommon central axis.The equation for calculating viscosity bythe parallel plate method is:5 2Mgh530Vdh/dt!2h31V!11T!(1)where:=viscosity,Pas,M=applied load,g,g=acceleration due to gravity,980 cm/s2,t=time,s,V=specimen volume,cm3,h=specimen thickness at time t,cm,dh/dt=compression rate,cm/s,and=glass mean coefficient of thermal expansion,25C tothe measurement temperature,T,m/m/C.See Note1.NOTE1The term(1+T)corrects for the specimen dimensionalchanges due to thermal expansion.For low thermal expansion glasses,itcan be ignored.However,for a glass with an of 20 10-6/C at ameasurement temperature of 1000C,this term produces a correction of2%.Only an estimate of is necessary since the correction is small.Usetwice the room temperature coefficient if data are unavailable.4.Significance and Use4.1 This test method is well suited for measuring theviscosity of glasses between the range within which rotationalviscometry(see Practice C965)is useful and the range withinwhich beam bending viscometry is useful(see Test MethodC1350M).It can be used to determine the viscosity/temperature curve in the region near the softening point(seeTest Method C338).This test method is useful for providinginformation related to the behavior of glass as it is formed intoan object of commerce,and in research and development.5.Apparatus5.1 The apparatus shall consist of a furnace,a means ofcontrolling and measuring its temperature and heating rate,1This test method is under the jurisdiction of ASTM Committee C14 on Glassand Glass Products and is the direct responsibility of Subcommittee C14.04 onPhysical and Mechanical Properties.Current edition approved Nov.1,2017.Published November 2017.Originallyapproved in 1996.Last previous edition approved in 2012 as C1351M 96(2012).DOI:10.1520/C1351M-96R17.2Fontana,E.H.,“A Versatile Parallel-Plate Viscometer For Glass ViscosityMeasurements to 1000C,”Bulletin of the American Ceramic Society,Vol 49,No.6,1970,pp.594597.3For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 specimen holders and loading rod,and a means of measuringthe rate of viscous compression of the glass specimen.5.2 Furnace:5.2.1 The furnace shall be electrically heated by resistanceelements.The dimensions and details of the furnace construc-tion are not critical;its cross-section can be circular of 75 mm(3 in.)diameter or square of sides of 75 mm.The furnaceshould have a constant temperature zone that covers thespecimen ge

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开