分享
ASTM_B_972_-_10_2014.pdf
下载文档

ID:184789

大小:108.53KB

页数:6页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_B_972_ _10_2014
Designation:B97210(Reapproved 2014)Standard Specification forNickel-Coated Braid and Ribbon Flat Copper Wire Intendedfor use in Electronic Application1This standard is issued under the fixed designation B972;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This specification covers nickel-coated copper braid andribbon flat wire intended for electronic application(Explana-tory Note 1).1.2 Two classes of nickel-coated braid and ribbon flatcopper wire are covered as follows:1.2.1 Class AAnnealed temper.1.2.2 Class HHard-drawn.1.3 The values stated in inch-pound units are to be regardedas standard.The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3.1 ExceptionsThe SI values for density,resistivity,andvolume are to be regarded as standard.1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2B1 Specification for Hard-Drawn Copper WireB3 Specification for Soft or Annealed Copper WireB49 Specification for Copper Rod Drawing Stock for Elec-trical PurposesB193 Test Method for Resistivity of Electrical ConductorMaterialsB258 Specification for Nominal Diameters and Cross-SectionalAreas ofAWG Sizes of Solid Round Wires Usedas Electrical Conductors2.2 Other Standards:3NBS Handbook 100 Copper Wire Tables3.Ordering Information3.1 Orders for material under this specification shall includethe following information:3.1.1 Quantity of each size,3.1.2 Wire size-thickness and width in inches(see 5.4),3.1.3 Class of wire(see 1.2),3.1.4 Type of copper,if special(see 4.2),3.1.5 Package size(see 10.1),3.1.6 Special packaging marking,if required,and3.1.7 Place of inspection(see 7.1).4.Material4.1 The material shall be nickel-coated flat wire(Explana-tory Note 1)of such quality and purity that the finished productshall meet the properties and characteristics prescribed in thisspecification.4.2 Copper-Base MetalThe base metal shall be copper ofsuch quality and purity that the finished product shall haveproperties and characteristics prescribed in this specification.NOTE1Specifications B1,B3,or B49 defines copper suitable for use.5.General Requirements(See Section 8)5.1 TemperThe nickel-coated flat wire conductor shall beprovided in either hard-drawn condition(Class H)or annealedcondition(class A)as agreed upon between the manufacturerand purchaser.5.2 Tensile and Elongation(Explanatory Note 2):5.2.1 Class AThe nickel-coated copper flat wire in theannealed condition shall conform to the elongation require-ments prescribed in Table 1.See Explanatory Note 3 forequivalent round diameter calculations based on given thick-ness and width dimensions for the flat wire.For flat wire whosenominal equivalent round diameter is more than 0.001 in.(0.025 mm)greater than a size listed in Table 1,but less thanthat of the next larger size,the requirements of the next largersize shall apply.No requirements for tensile strength arespecified.1This specification is under the jurisdiction of ASTM Committee B01 onElectrical Conductors and is the direct responsibility of Subcommittee B01.04 onConductors of Copper and Copper Alloys.Current edition approved Oct.1,2014.Published October 2014.Originallyapproved in 2010.Last previous edition approved in 2010 as B972 10.DOI:10.1520/B0972-10R14.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from National Technical Information Service(NTIS),5285 PortRoyal Rd.,Springfield,VA 22161,http:/www.ntis.gov.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 5.2.2 Class HThe nickel-coated copper flat wire in thehard drawn condition shall conform to elongation requirementsof 1%minimum to 5%maximum.The tensile strength shallbe 55 000 psi(379 MPa)minimum.5.3 Resistivity(Explanatory Note 4)The electrical resis-tivity of the coated wire at a temperature of 20C shall notexceed the values prescribed in Table 2.5.4 Dimensions and Permissible VariationsThe flat wiresizes shall be expressed as the thickness and width of the wirein decimal fractions of an inch to the nearest 0.0001 in.(0.0025mm).The nickel-coated flat wire shall not vary from thespecified thickness and width by more than the amountsspecified in Table 3 and Table 4,respectively.5.5 Continuity of CoatingThe nickel

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开