分享
ASTM_C_1459_-_04_2019.pdf
下载文档

ID:184675

大小:125.28KB

页数:4页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_C_1459_ _04_2019
Designation:C145904(Reapproved 2019)Standard Specification forPerformance of Non-Asbestos Fiber-Reinforced CementShake,Shingle,and Slate Roofing Systems1This standard is issued under the fixed designation C1459;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This specification covers the performance of non-asbestos,fiber-reinforced cement shake,shingle,and slateroofing systems that are of uniform or nonuniform thicknessand texture.1.2 This specification does not include details of productinstallation and workmanship.The manufacturers installationinstructions shall be referred to for details such as slope,interlayment,underlayment,sheathing requirements,exposure,fasteners,and repair or replacement instructions.1.3 This specification does not address requirements forindividual shake,shingle,and slate products,which are cov-ered in Specification C1225 and C1530/C1530M.1.4 The tests contained in this specification are intended asqualification tests for a roofing system.Changes in productformulation,design,or manufacturing process beyond theranges allowed in the manufacturers quality controlspecifications,shall require subsequent system retesting orwritten concurrence by an independent testing agency that thechanges in formulation,design,or manufacturing process willnot be detrimental to system performance.1.5 The values stated in inch-pound units are to be regardedas standard.The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.6 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2C1154 Terminology for Non-Asbestos Fiber-Reinforced Ce-ment ProductsC1185 Test Methods for Sampling and Testing Non-Asbestos Fiber-Cement Flat Sheet,Roofing and SidingShingles,and ClapboardsC1225 Specification for Fiber-Cement Roofing Shingles,Shakes,and SlatesC1530/C1530M Specification for Non-Asbestos Fiber-Cement Roofing Shakes,Shingles,and Slates with De-signed Varying Profiles and ThicknessesE108 Test Methods for Fire Tests of Roof Coverings3.Terminology3.1 DefinitionsRefer to Terminology C1154.4.Significance and Use4.1 This specification addresses key performance aspects offiber-reinforced cement roofing systems.Aspects of perfor-mance such as aesthetics,hail resistance,wind resistance,wind-driven rain resistance,and items referenced in 1.2 are notaddressed in this specification.Additional properties,whichmay influence system performance,are addressed in Specifi-cations C1225 and C1530/C1530M.5.Performance Requirements5.1 Installed Strength TestThe failure loads for the equi-librium and wet specimens shall be as required in Table 1 whentested in accordance with Section 6.5.2 Installed Weight TestDetermine the weight in accor-dance with Section 7.5.3 Accelerated Aging(Wet/Dry Cycling Test)There shallbe no signs of additional damage or cracking when examined1This specification is under the jurisdiction of ASTM Committee C17 onFiber-Reinforced Cement Productsand is the direct responsibility of SubcommitteeC17.02 on Non-Asbestos Fiber Cement Products.Current edition approved Feb.1,2019.Published February 2019.Originallyapproved in 2000.Last previous edition approved in 2014 as C1459 04(2014).DOI:10.1520/C1459-04R19.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 under 5 magnification,and the ratio of strength(R)shall be atleast 0.90,when tested in accordance with Section 8.5.4 Accelerated Aging(Heat/Rain Test)Report any dam-age or structural alteration caused by the effect of stressesaround the fasteners

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开