分享
ASTM_C_1133_-_C_1133M_-_10_2018.pdf
下载文档

ID:184440

大小:265.62KB

页数:17页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_C_1133_ _C_1133M_ _10_2018
Designation:C1133/C1133M10(Reapproved 2018)Standard Test Method forNondestructive Assay of Special Nuclear Material in Low-Density Scrap and Waste by Segmented Passive Gamma-Ray Scanning1This standard is issued under the fixed designation C1133/C1133M;the number immediately following the designation indicates the yearof original adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.A superscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method covers the transmission-corrected non-destructive assay(NDA)of gamma-ray emitting specialnuclear materials(SNMs),most commonly235U,239Pu,and241Am,in low-density scrap or waste,packaged in cylin-drical containers.The method can also be applied to NDA ofother gamma-emitting nuclides including fission products.High-resolution gamma-ray spectroscopy is used to detect andmeasure the nuclides of interest and to measure and correct forgamma-ray attenuation in a series of horizontal segments(collimated gamma detector views)of the container.Correc-tions are also made for counting losses occasioned by signalprocessing limitations(1-3).21.2 There are currently several systems in use or underdevelopment for determining the attenuation corrections forNDA of radioisotopic materials(4-8).A related technique,tomographic gamma-ray scanning(TGS),is not included inthis test method(9,10,11).1.2.1 This test method will cover two implementations ofthe Segmented Gamma Scanning(SGS)procedure:(1)IsotopeSpecific(Mass)Calibration,the original SGS procedure,usesstandards of known radionuclide masses to determine detectorresponse in a mass versus corrected count rate calibration thatapplies only to those specific radionuclides for which it iscalibrated,and(2)Efficiency Curve Calibration,an alternativemethod,typically uses non-SNM radionuclide sources todetermine system detection efficiency vs.gamma energy andthereby calibrate for all gamma-emitting radionuclides ofinterest(12).1.2.1.1 Efficiency Curve Calibration,over the energy rangefor which the efficiency is defined,has the advantage ofproviding calibration for many gamma-emitting nuclides forwhich half-life and gamma emission intensity data are avail-able.1.3 The assay technique may be applicable to loadings up toseveral hundred grams of nuclide in a 208-L 55-gal drum,with more restricted ranges to be applicable depending onspecific packaging and counting equipment considerations.1.4 Measured transmission values must be available for usein calculation of segment-specific attenuation corrections at theenergies of analysis.1.5 A related method,SGS with calculated correction fac-tors based on item content and density,is not included in thisstandard.1.6 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard.The values stated ineach system may not be exact equivalents;therefore,eachsystem shall be used independently of the other.Combiningvalues from the two systems may result in non-conformancewith the standard.1.7 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.Specific precautionary statements are given in Section 10.1.8 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for the1This test method is under the jurisdiction ofASTM Committee C26 on NuclearFuel Cycle and is the direct responsibility of Subcommittee C26.10 on NonDestructive Assay.Current edition approved April 1,2018.Published April 2018.Originallyapproved in 1996.Last previous edition approved in 2010 as C1133/C1133M 10.DOI:10.1520/C1133_C1133M-10R18.2The boldface numbers in parentheses refer to the list of references at the end ofthis test method.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 Development of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:3C1030 Test Method for Determination of Plutonium IsotopicComposition by Gamma-Ray SpectrometryC1128 Guide for Preparation of Working Reference Materi-als for Use in Analysis of Nuclear Fuel Cycle MaterialsC1156 Guide for Establishing Calibration for a Measure-ment Method Used to Analyze Nuclear Fuel Cycle Mate-rialsC1207 Test

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开