温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_C_716_
_06_2015
Designation:C71606(Reapproved 2015)Standard Specification forInstalling Lock-Strip Gaskets and Infill Glazing Materials1This standard is issued under the fixed designation C716;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This specification covers installation procedures forlock-strip gaskets that comply with Specification C542 and forinfill glazing materials in lockstrip gasket glazing applicationsused in building walls which are not more than 15 from avertical plane.The prime performance considerations areweathertightness against air and water infiltration,and struc-tural integrity under wind loads.1.2 The values stated in SI units are to be regarded asstandard.The values given in parentheses are provided forinformation only.1.3 The committee with jurisdiction over this standard is notaware of any comparable standards published by other orga-nizations.2.Referenced Documents2.1 ASTM Standards:2C542 Specification for Lock-Strip GasketsC717 Terminology of Building Seals and SealantsC963 Specification for Packaging,Identification,Shipment,and Storage of Lock-Strip GasketsC964 Guide for Lock-Strip Gasket Glazing3.Significance and Use3.1 This specification can be referred to in contract docu-ments as a method and workmanship standard for the installa-tion of lock-strip gasket glazing systems.See also relatedstandards(Specifications C542 and C963,Guide C964,andTerminology C717).4.Installation4.1 Inspection of ComponentsBefore installing gaskets,the installer shall check the mounting frames to see that theyare within specified dimensional tolerances and not out-of-square or plane,and check all gaskets for type,dimensions,anddefects such as misalignment at molded corners and damagedlips.Installation shall not proceed until corrections have beenmade.4.2 Environmental ConditionsMaximum efficiency andsealing capability of gaskets is achieved in a clean,dry,warmenvironment,with the gasket kept resilient during the entireinstallation process.During cold weather the use of temporaryenclosures around the units to be glazed or paneled willfacilitate temperature control and also aid in keeping opengasket channels clean and dry.4.3 Preparation and Conditioning of GasketsLock-stripgaskets require conditioning prior to installation in order torestore maximum resiliency and remove deformations afterprolonged storage in a coiled or stressed position.Gaskets shallbe unpacked from their containers and conditioned for 24 h ina temperature not lower than 21.1C(70F)by being placedflat or hung on racks to permit recovery of their originalshapes.Racks shall be free of rough surfaces,projections,sharp edges,and other conditions that could damage thegaskets.When the ambient temperature is 10C(50F)orbelow and a heated space is not available,gaskets shall beheated by other means to remove deformations and provide ahigh degree of flexibility and resiliency.This may be done bywarming them in hot water or heated containers.Gaskets shallnot be heated by being draped over heated units or placed indirect contact with a flame or fired heating device.Theinstallation of glass,panel,and lock-strip shall be completedwhile the gasket is still warm and pliable and with the gasketchannels clean and dry.4.4 Use of ToolsTo minimize the possibility of damage,sharp or pointed tools or implements such as screwdrivers orputty knives shall not be used on lock-strip gaskets.Suitablegasket installation tools,such as nonmetallic spatulas andengineered lock-strip insertion devices,are available from thegasket manufacturer.4.5 Use of LubricantsIf necessary a lubricant may beapplied to the contact surfaces of the gasket to ease theinstallation and help prevent damage to the gasket,glass,orpanel.Thelubricantshallbenonstaining,nontoxic,noncorrosive,chemically stable,compatible with all contactcomponents,easily removable from exposed surfaces by dry1This specification is under the jurisdiction of ASTM Committee C24 onBuilding Seals and Sealantsand is the direct responsibility of Subcommittee C24.73on Compression Seal and Lock Strip Gaskets.Current edition approved Dec.1,2015.Published December 2015.Originallyapproved in 1973.Last previous edition approved in 2011 as C716 06(2011).DOI:10.1520/C0716-06R15.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 wiping or with water,and acceptable to the manufacturer of thesupporting frame,panel,and gasket.4.6 Use of Supplementary Wet SealantsThe use of supple-mentary wet sealants in c