分享
ASTM_C_663_-_98_2014.pdf
下载文档

ID:183967

大小:72.10KB

页数:4页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_C_663_ _98_2014
Designation:C66398(Reapproved 2014)Standard Specification forAsbestos-Cement Storm Drain Pipe1This standard is issued under the fixed designation C663;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S.Department of Defense.1.Scope1.1 This specification covers asbestos-cement pipe intendedfor use in storm-water drainage of highways,airports,farms,foundations,and other similar drainage systems.1.2 The values stated in SI units are to be regarded as thestandard.The values stated in parentheses are for informationonly.1.3 WarningBreathing of asbestos dust is hazardous.Asbestos and asbestos products present demonstrated healthrisks for users and for those with whom they come into contact.In addition to other precautions,when working with asbestos-cement products,minimize the dust that results.For informa-tion on the safe use of chrysoltile asbestos,refer to“Safe Useof Chrysotile Asbestos:A Manual on Preventive and ControlMeasures.”21.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.See for a specifichazard warning.2.Referenced Documents2.1 ASTM Standards:3C150 Specification for Portland CementC458 Test Method for Organic Fiber Content of Asbestos-Cement ProductsC500 Test Methods for Asbestos-Cement PipeC595 Specification for Blended Hydraulic CementsD2946 Terminology for Asbestos and AsbestosCementProducts2.2 Federal Standard:Fed.Std.No.123 Marking for Shipment(Civil Agencies)42.3 Military Standard:MIL-STD-129 Marking for Shipment and Storage42.4 Other Standards:Uniform Freight Classification Rules5National Motor Freight Classification Rules63.Terminology3.1 Definitions:3.1.1 coupling,nin asbestos-cement conduit,sewer,un-derdrain and storm drain pipecomponent made from a largerdiameter pipe of the same type or class,or of Type II and ahigher class,or produced otherwise to yield at least equalperformance,for joining asbestos-cement pipe that whenproperly installed,forms a silt-tight joint,allows alignmentcorrections and slight changes in direction,and provides anassembled joint equivalent in serviceability and strength to thepipe sections.Alternatively,for storm drain couplings,plasticsleeves that,when properly installed develop sufficient tight-ness to prevent the surrounding soil from entering the drain,may be used as couplings.3.1.2 lot,nfor pipe sizes 525 mm(21 in.)in diameter andsmaller,each 300 lengths of pipe or less,of identical class andsized manufactured on each machine during a 24-h period.Forpipe larger than 525 mm(21 in.),each 300 lengths of pipe orless,of identical class and size manufactured on each machineduring a period of consecutive working days not exceedingseven days.3.1.3 Additional terminology is given in TerminologyD2946.4.Classification4.1 The types of pipe shall be shown as Type I and Type IIcorresponding to the chemical requirements given in 10.1.1This specification is under the jurisdiction of ASTM Committee C17 onFiber-Reinforced Cement Products and is the direct responsibility of C17.03 onAsbestos-Cement Sheet Products and Accessories.Current edition approved Dec.1,2014.Published December 2014.Originallyapproved in 1970.Last previous edition approved in 2008 as C663 98(2008).DOI:10.1520/C0663-98R14.2Available from The Asbestos Institute,http:/ referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.4Available from Standardization Documents Order Desk,Bldg.4,Section D,700 Robbins Ave.,Philadelphia,PA 19111-5094 Attn:NPODS.5Available from the Uniform Classification Commission,Room 1106,222 S.Riverside Plaza,Chicago,IL 60606.6Available from National Motor Freight Inc.,1616 P St.NW,Washington,DC20036.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 4.2 Asbestos-cement storm drain pipe furnished under thisspecification shall be designated as Class II,III,2500D,IV,andV.The corresponding strength requirements are prescribed inTable 1.The D1load is the crushing test load expressed innewtons per linear metre per of diameter.(The D load is thecrushing test load expressed in pounds-force per linear ft per ftof diameter.)The pipe shall be furnished in 10,15,20,25,30,36,38,41,46,51,53,61,69,76,84,91,99 and 107-cm sizes(4,6,8,10,12,14,15,16,18,20,21,24,27,30,33,36,39 and42-in.sizes).5.Materials and Manufacture5.1 Asbestos-cement storm drain

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开