分享
ASTM_D_1512_-_15b.pdf
下载文档

ID:183765

大小:90.89KB

页数:4页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_1512_ _15b
Designation:D151215bStandard Test Methods forCarbon BlackpH Value1This standard is issued under the fixed designation D1512;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S.Department of Defense.1.Scope1.1 These test methods,Test MethodABoiling Slurry andTest Method BSonic Slurry,are used to indicate the pH ofthe carbon black surface by measuring the pH of water incontact with the carbon black.NOTE1The pH of the carbon black is often used in this industry toindicate the relative acidity or alkalinity of carbon black and will be usedin the remainder of these test methods to describe this property.NOTE2Test Method A and Test Method B do not always give thesame results.1.2 The values stated in SI units are to be regarded as thestandard.The values in parentheses are for information only.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD1799 Practice for Carbon BlackSampling PackagedShipmentsD1900 Practice for Carbon BlackSampling Bulk Ship-mentsD4483 Practice for Evaluating Precision for Test MethodStandards in the Rubber and Carbon Black ManufacturingIndustriesE70 Test Method for pH of Aqueous Solutions With theGlass Electrode3.Significance and Use3.1 The pH level of a carbon black is known to affect thevulcanization of some rubber compounds.TEST METHOD ABOILING SLURRY4.Apparatus4.1 pH Meter,(digital is recommended)having an accuracyof 60.05 pH and equipped with a combination electrode andRNC connector.4.2 Container,stainless steel or copper,125 cm3or larger.4.3 Hot Plate.4.4 High Speed Mill,Mixer or Mortar and Pestle.4.5 Beakers,glass,100 cm3graduated with watch glasses.4.6 Magnetic Stir Plate.4.7 Magnetic Stir Bars.5.Reagents5.1 Purity of ReagentsReagent grade chemicals shall beused in all tests.Unless otherwise indicated,it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.3Other grades may beused,provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.5.2 Purity of WaterUnless otherwise indicated,referencesto water shall be understood to mean reagent water as definedby Type 1 in Specification D1193.5.3 Distilled Water,high purity.5.4 Buffer Solutions,pH of 4.00,7.00,and 10.00.5.5 Acetone,reagent grade.6.Sampling6.1 Samples shall be taken in accordance with PracticesD1799 or D1900.1These test methods are under the jurisdiction of ASTM Committee D24 onCarbon Black and are the direct responsibility of Subcommittee D24.31 onNon-Carbon Black Components of Carbon Black.Current edition approved Dec.1,2015.Published February 2016.Originallyapproved in 1975.Last previous edition approved in 2015 as D1512 15a.DOI:10.1520/D1512-15B.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Reagent Chemicals,American Chemical Society Specifications,AmericanChemical Society,Washington,DC.For suggestions on the testing of reagents notlisted by the American Chemical Society,see Analar Standards for LaboratoryChemicals,BDH Ltd.,Poole,Dorset,U.K.,and the United States Pharmacopeiaand National Formulary,U.S.Pharmacopeial Convention,Inc.(USPC),Rockville,MD.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 7.Calibration7.1 Calibrate the pH meter using buffer solutions accordingto manufacturers instructions.8.Procedure8.1 Pulverize pelleted or lumpy carbon black to a finepowder,using either the high speed mixer or mortar and pestle.8.2 Prepare boiling distilled water in a stainless steel beaker.8.3 Weigh carbon black and boiling distilled water into aglass beaker or boiling flask and add 2 to 3 drops of acetone tofacilitate wetting of the sample.The carbon black weight andvolume of water is maintained at a constant ratio of 1:10.SeeTable 1 for selection of carbon black weight,volume of waterand beaker or boiling flask volume.NOTE3A stainless steel beaker is used to eliminate contaminationduring boiling.8.4 Cover the glass beaker with a watch glass and boil themixture for 15 min,but do not allow all the liquid to evaporate.8.5 Let the mixture cool to room temperature in a

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开