分享
ASTM_D_1319_-_15.pdf
下载文档

ID:183563

大小:251.69KB

页数:9页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_1319_ _15
Designation:D131915Standard Test Method forHydrocarbon Types in Liquid Petroleum Products byFluorescent Indicator Adsorption1This standard is issued under the fixed designation D1319;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S.Department of Defense.1.Scope*1.1 This test method covers the determination of hydrocar-bon types over the concentration ranges from 5 to 99 volume%aromatics,0.3 to 55 volume%olefins,and 1 to 95 volume%saturates in petroleum fractions that distill below 315 C.Thistest method may apply to concentrations outside these ranges,but the precision has not been determined.Samples containingdark-colored components that interfere in reading the chro-matographic bands cannot be analyzed.NOTE1For the determination of olefins below 0.3 volume%,othertest methods are available,such as Test Method D2710.1.2 This test method is intended for use with full boilingrange products.Cooperative data have established that theprecision statement does not apply to narrow boiling petroleumfractions near the 315 C limit.Such samples are not elutedproperly,and results are erratic.1.3 This test method includes a relative bias section basedon Practice D6708 accuracy assessment between Test MethodD1319 and Test Method D5769 for total aromatics in spark-ignition engine fuels as a possible Test Method D1319 alter-native to Test Method D5769 for U.S.EPA spark-ignitionengine fuel regulations reporting.The Practice D6708 derivedcorrelation equation is only applicable for fuels in the totalaromatic concentration range from 3.3%to 34.4%by volumeas measured by Test Method D1319 and the distillationtemperature T95,at which 95%of the sample has evaporated,ranges from 149.1 C to 196.6 C(300.3 F to 385.8 F)whentested according to Test Method D86.1.3.1 The applicable Test Method D5769 range for totalaromatics is 3.7%to 29.4%by volume as reported by TestMethod D5769 and the distillation temperature T95values,atwhich 95%of the sample has evaporated,when testedaccording to Test Method D86 is from 149.1 C to 196.6 C(300.3 F to 385.8 F).1.4 The applicability of this test method to products derivedfrom fossil fuels other than petroleum,such as coal,shale,ortar sands,has not been determined,and the precision statementmay or may not apply to such products.1.5 This test method has two precision statements depictedin tables.The first table is applicable to unleaded fuels that donot contain oxygenated blending components.It may or maynot apply to automotive gasolines containing lead antiknockmixtures.The second table is applicable to oxygenate blended(for example,MTBE,ethanol)automotive spark ignition fuelsamples with a concentration range of 13 to 40 volume percentaromatics,4 to 33 volume percent olefins,and 45 to 68 volumepercent saturates.1.6 The oxygenated blending components,methanol,ethanol,methyl-tert-butylether(MTBE),tert-amylmethylether(TAME),and ethyl-tert-butylether(ETBE),do not interferewith the determination of hydrocarbon types at concentrationsnormally found in commercial blends.These oxygenatedcomponents are not detected since they elute with the alcoholdesorbent.Other oxygenated compounds shall be individuallyverified.When samples containing oxygenated blending com-ponents are analyzed,correct the results to a total-sample basis.1.7 WARNINGMercury has been designated by manyregulatory agencies as a hazardous material that can causecentral nervous system,kidney and liver damage.Mercury,orits vapor,may be hazardous to health and corrosive tomaterials.Caution should be taken when handling mercury andmercury containing products.See the applicable product Ma-terial Safety Data Sheet(MSDS)for details and EPAswebsitehttp:/www.epa.gov/mercury/faq.htmfor addi-tional information.Users should be aware that selling mercuryand/or mercury containing products into your state or countrymay be prohibited by law.1.8 The values stated in SI units are to be regarded asstandard.1.8.1 ExceptionInch-pound units in parentheses are pro-vided for information only.1.9 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is the1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products,Liquid Fuels,and Lubricants and is the direct responsibility ofSubcommittee D02.04.0C on Liquid Chromatography.Current edition approved Dec.1,2015.Published December 2015.Originallyapproved in 1954.Last previous edition approved in 2014 as D1319 14.DOI:10.1520/D1319-15.*A Summary of Changes section appears at the end of this standardCopyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 responsibility of the user of this standard to es

此文档下载收益归作者所有

下载文档
猜你喜欢
你可能关注的文档
收起
展开